Checkoff Sheet MS-2014-02482.tif 2009 INTERNATIONAL RESIDENTIAL CODE'
CITY OF BLAIR REROOFING CHECKOFF SHEET
Return to Blair Cid Full prior to Final inspection
218 s le street, stair, NE 68008
0ecause of limitations caused by the infeasibility to perform dstaftd inspectlons which would
not Interfere with reroofing work,pleaso indicate cumplianoe with the following req,uiremenfs
fol winEt this reroofing job.
Property Address: Y`� ' ''=•
Contractor or Homeowner(if self
Permit#: � fl�.�,'� '
Installation Vate-
YES NO
�7
"The materlals and methods of application used for recovering or replacing the existing
roof covering comply with the requirements of the building code- (R907.'1)
I� ICE PROTECT[ON INSTALLED,An los barrier that consists of at least two layers of
underiayment or of a self-adhering polymer modified bitumen sheet was installed and
extends at least from the aaye's•edge to a point at least 24 Inches Maids the oxterior
wall Brie of the building. (11006.2.7,1)
C3 a-rpUCTURAL COMPONENTS AR5�OUNDI The structural roof components are
capable of supporting the roof oovbting system and the material and equipment loads
that will be encountered during installation of the roof covering system. (R907.2)
l KISTi O COVERIN—P WAS R moVED4 Pxlsting roof covering was removed for one
of the reasons required by seotlon 8507.6
DID No-r USP RUST50 METAL OR FLASHING: r:Msting vent flashing, metal edges,
drain outlets;Qollars or metal counter-flashing were not retnstalied if rusted. (R907.6)
` ❑ F� �,SH[NC iNSTALLI=Ia ltiaPli4Y: Flashing shall be reconstructed in accordance
with appioved manufacturer's installation instructions.Metal flashing to which
bituminous materials are to be adhered shall be primed prior to Instaliatlon.•(1807.6)
Signa re o Pri Inst r Date
1 ' 1
Signature&f Permit Md6r date