CITY BLAIR REROOFING CHECKOFFSHEET �
Return to Blair City Hall'prior to Final Inspection
218 Sl6 Street, Blair, NB 68®8$
Because of limitations caused by the infeasibility toperform detailed inspections which would
not interfere with reroofing work, please indicate compliance with the following requirements
follow'ing this reroofing job.
hermit#: `
Installation Date: - -
YES/
ES NO
The materials and methods of application used for recovering or replacing the existing
roof covering comply with the requirements of the building code. (R907.1)
1 ICE PROTECTION INSTALLED:An ice barrier that consists of at least two layers of
/ underlayment or of a self-adhering polymer modified bitumen sheet was installed and
extends at least from the eave's edge to a point at least 244 inches inside the exterior
wall line of the building. (R905.2.7.1)
STRUCTURAL COMPONENTS ARE SOUND:The structural roof components are
capable of supporting the roof covering system and the material and equipment loads
that will be encountered during installation of the roof covering system. (8907.2)
0 EXISTING COVERING WAS REMOVED., Existing roof•covering was removed for one
of the reasons required by section 8907.3
NO RUSTED METAL" OR FLASHING: Existing Ment flashing, metal edges, drain
outlets, collars or metal counter-flashing were not reinstalled if rusted. (R907.5)
4
❑. FLASHING INSTALLED PROPERLY: Clashing shall be reconstructed in accordance
with approved manufacturer's installation instructions. Metal flashing to which
bituminous materials are to be adhered shall be primed prior to installation. (R907.6)
/ZA 4/�'
Signaf a Primary Installer ate
Date
Signature of Pe It Holder �