N'TERNAT10 RESIDENTIAL CODE
CITY OF BLAIR REROOFING CHECKOFF SHEET.
ettirn to BlairCity Hall prior to Final Inspect`o
218 S 16 Street, Blair, NE 68008
Because of limitations caused by the infeasibility to perform detailed 1nsp66tions which would
not interfere with reroofing work, please indicate compliance with the following requirements
followiing this- reroofing job.
PropertyAddressp �� IV �5r BIAW
Contractor or Homeowner (if self}
Permit #: S- 2014- 013,:Q
Installation Date: /4 ~-/ 7
YES . No
The materials and methods of application used for recovering or replacing the exisfing
roof covering comply with the requirements'of the building code. (R907.1)
i
ICE PROTECTION INSTALLED An ice barrier that consists of at least two layers of
underlayment or of a self-adhering polymelr modified b(tumen sheet was installed and
extends at least from tiie e'ave's edge to a point at least 24 inches inside the exterior
wall sine of the building. (8905.2.7.1)
l STRUCTURAL C0MP0Ni =NTS ARE -SOUND.- The structural•roof components are
capable of supporting tie roof covering, system and the material and equipment loads
thaf,will be encountered during Installation of the roof covering system_ (8907.2)
EXISTING COHERING WAS REMOVED. Existing roof covering vitas removed for one
of the reasons required by section k907.3
DID -NOT USE RUSTED METAL OR FLASHING: Existing vent flashing, metal edges,
drain outlets, collars or metal counter flashing were not reinstalled if rusted. (R907.6)
FLASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance
inrith approved manufacturer's installation instructions. Metal flashing to which j
bituminous materials are to be adhered shall be primed prior to installation. (R907.6)
Signature of P imary ;taller D e
Signature of Permit Holder Date