Loading...
Telecommunications TowerUNION PACIFIC RAILROAD 1400 Douglas Street, Stop 1580 Patrick R. McGill /U PC Senior Counsel -Real Estate, Law Dept. Omaha, Nebraska 68179 P 402 544 5761 F 402 997 3603 prmcgill @up.com August 28, 2012 City of Blair, Nebraska Attn: City Administrator Rodney Storm 218 South 16 Street Blair, NE 68008 Re: Union Pacific Railroad Company Telecommunications Tower Blair, Nebraska Dear Mr. Storm: Union Pacific Railroad Company (UP) has constructed a new telecommunications tower and an adjacent building on UP property in the City of Blair. The tower is an approximately 199 foot self - supporting tower, and the building is one story, approximately ten feet long by twelve feet wide. The tower supports telecommunication equipment used by UP in its railroad operations. As I understand Brenda Mainwaring, UP's Director of Public Affairs, has explained to you or your staff, UP is a common carrier freight railroad subject to regulation by the Surface Transportation Board (STB) under the Interstate Commerce Commission Termination Act of 1995 ( ICCTA). ICCTA provides for the STB to have exclusive jurisdiction over all matters relating to the construction, acquisition, operation, abandonment, or discontinuance of railroad infrastructure and /or facilities. This provision specifying exclusive jurisdiction of the STB has been interpreted by Courts, including the United States Supreme Court, to preempt state and local authority over such matters, absent a specific waiver. This federal preemption of local authority does not mean that UP has constructed a facility that is not protective of human health, safety or the local environment. Regardless of the exclusive jurisdiction of the STB over UP's railroad facilities, UP is prepared to discuss with you or your staff the details related to UP's project and any concerns you and your staff ever have with the new tower. We have attached a copy of the "as- built" specifications of the tower for your records. If you have further questions or concerns you wish to discuss, please contact Brenda Mainwaring at 402 -544 -4749. www.up.com a BUILDING Thank you for your time and consideration. Sincerely, Patrick R. McGill Cc: Jason Butler (via email) Brenda Mainwaring (via email) M C� w a a 0 w �I v S� 6 O rff( N a X95.0' 190.0' 100.0' 175.0' 160.0' 155.0' 140.0' 135.0' 120.0' 115.0' 100.0' 50.0' 10.0' :4.0' ' PLAN NDTES' 1. The tower model is M Series SD. 2. Transnission_ lines are to be attached to standard 0 hole waveguide ladders. 3. Azimuths are relative (not based on true north). 4. roundatior. loads shown are ma inums. 5. (6) 1 114" d,a. F1554 grade 105 anchor bolts per leg. Minimum 45.5" embedxent from top of concrete to top of nu 6. All unequal angles are oriented with C:te short leg vertical. 7. This tower was designer( for structure class iI, Exposure Category C and Topographic Category 1. 0. The foundation Ioads shown below are factored "loads. ANTEITRA LIST WD EEV u TX-:.INE 1 195' .e (1) 1/2 U + 3ft Sidearn 2 0 (1) Da806 3 195' (1) aft Sidearn (1; 1!2 g, 195' ;1) 57212 N '-1 Il) 7/8 6 18715' ,1) 0606 -915 ry 187.5' {11 soli0 0 i85' Ill 3ft Sidearm tl; 1/2 9 as t2) 6' Solid Dish (2) EW63 N M W/ Radome 10 180' (11 aft Sidearm (1) :/2 11 O M 6' " x 3in (6) 1 5/8 + 10' 3T- Coom(R) V 12 180' (11 SDZ22. 13 .75' 11) aft Sidearm (1) 112 n N N w m f3 ou m N 4n J .�1 M o- N ti m 9 ;a e a� N a J to isa uj r1 �n M w �a. th tq ° t o pc X95.0' 190.0' 100.0' 175.0' 160.0' 155.0' 140.0' 135.0' 120.0' 115.0' 100.0' 50.0' 10.0' :4.0' ' PLAN NDTES' 1. The tower model is M Series SD. 2. Transnission_ lines are to be attached to standard 0 hole waveguide ladders. 3. Azimuths are relative (not based on true north). 4. roundatior. loads shown are ma inums. 5. (6) 1 114" d,a. F1554 grade 105 anchor bolts per leg. Minimum 45.5" embedxent from top of concrete to top of nu 6. All unequal angles are oriented with C:te short leg vertical. 7. This tower was designer( for structure class iI, Exposure Category C and Topographic Category 1. 0. The foundation Ioads shown below are factored "loads. ANTEITRA LIST WD EEV A1ITEN4A TX-:.INE 1 195' (1) RY -900R (1) 1/2 + 3ft Sidearn 2 196' (1) Da806 3 195' (1) aft Sidearn (1; 1!2 4 195' ;1) 57212 190' ;1) 3ft Sideara, Il) 7/8 6 18715' ,1) 0606 -915 1 187.5' {11 soli0 0 i85' Ill 3ft Sidearm tl; 1/2 9 as t2) 6' Solid Dish (2) EW63 W/ Radome 10 180' (11 aft Sidearm (1) :/2 11 160' M 6' " x 3in (6) 1 5/8 + 10' 3T- Coom(R) 12 180' (11 SDZ22. 13 .75' 11) aft Sidearm (1) 112 MATERIAL LIST NO TYPE A SR 1 - 3/4^ o B t 2 11 ::2"::3/16' C IL AMV R p a g�y 7 y reject: C. \Ou:put \S3RSD \- 4065:.LOD Sheet: 1 f Sabrer To wers & Poles w No.: 40651 Page: 3 Date: 21241'11 By: REB 195 ft. Model S3R Series SD Self Supporting Tower At 90 mph Wind with no ice and 50 mph Wind with 0.75 in. Ice per ANSI1TIA -222 -G -2005. Antenna Loading per Page 1 2 6' Grade — Dia. -- i I Two (2) #4 ties within top 5" of concrete j L -- - -_I 1 I 1 I I Notes: 1). Concrete shall have a minimum 28 -day compressive strength of 4000 PSI, In accordance with AC1 318 -05. i I i I i I I i t--- - -_—I I I I i 1 I I I I I I I ELEVATION VIEW (6.45 Cu. Yds. each) (3 REQUIRED; NOT TO SCALE) 2). Rebars to conform to ASTM specification A615 Grade 60. 3). All rebar to have a minimum of 3" concrete cover. 4). All exposed concrete corners to be chamfered 3/4 5). The foundation design is based on the geotechnicai report by TG project no. 10448.00, dated: 10/29/10 6). See the geotechnical report for drilled pier installation requirements, if specified. 7). The foundation is based on the following factored loads: Factored uplift (kips) = 217.22 Factored download (kips) = 242.8 Factored shear (kips) = 17.9 Rebar Schedule per Pier (10) #9 vertical rebar w/#4 ties, two (2) Pier within top 5" of pier then 12" C/C Information contained herein is the sole property of Sabre Towers & Poles, constitutes a trade secret as defined by Iowa Code Ch. 650 and shall not be reproduced, copied or used in whole or part for any purpose whatsoever without the prior written consent of Sabre Towers & Poles. 2101 Murray St - P.O. Box 658 - Sioux City, IA 51102 -0658 - Phone 712.258.6690 Fax 712.258:8250 DrawResults 'Copyright (C) Guymast Inc, 2010 Phone:(416) 736 -745 Licensed to: Sabre Communications Corporation M&xi.mum alev (f t) 195.0 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 24 feb 2011 11 :44:16 195.0 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 7.5 5 2.5 0 2.5 5 7.5 Project: C: \Output \S3RSD \40651.MST Page Compression in Diagonals (kip) Tension in Diagonals (kip) 7.5 5 2,5 0 2.5 5 7.5 40651.txt MAST - Latticed Tower Analysis (Unguyed) (c)1997 Guymast Inc. 416 -736 -7453 Processed under license at: sabre Communications corporation on: 24 feb 2011 at: 11:39:51 MAST GEOMETRY ( ft PANEL NO.OF ELEV.AT ELEV.AT F.W..AT F.W..AT TYPICAL TYPE LEGS BOTTOM TOP BOTTOM TOP PANEL ft ft in.sq in ksi HEIGHT x 3 190.00 195.00 5.00 5.00 5.00 x 3 180.00 190.00 5.00 5.00 5.00 x 3 175.00 180.00 5.00 5.00 5.00 x 3 160.00 175.00 5.00 5.00 5.00 x 3 155.00 160.00 5.00 5.00 5.00 x 3 140.00 155.00 5.00 5.00 5.00 x 3 135.00 140.00 5.00 5.00 5.00 x 3 120.00 135.00 5.00 5.00 5.00 x 3 115.00 120.00 5.44 5.00 5.00 x 3 100.00 115.00 6.75 5.44 5.00 x 3 80.00 100.00 8.50 6.75 5.00 x 3 60.00 80.00 10.25 8.50 5.00 x 3 40.00 60.00 12.00 10.25 5.00 x 3 20.00 40.00 13.75 12.00 6.67 x 3 0.00 20.00 15.50 13.75 6.67 MEMBER PROPERTIES MEMBER BOTTOM TOP X -SECTN RADIUS ELASTIC THERMAL TYPE ELEV ELEV AREA OF GYRAT MODULUS ExPANSN ft ft in.sq in ksi /deg LE 180.00 195.00 2.405 0.438 29000. 0.0000116 LE 160.00 180.00 3.142 0.438 29000. 0.0000116 LE 140.00 160.00 4.909 0.438 29000. 0.0000116 LE 100.00 140.00 7.069 0.438 29000. 0.0000116 LE 60.00 100.00` 8.296 0.438 29000. 0.0000116 LE 40.00 60.00 9.621 0.438 29000. 0.0000116 LE 20.00 40.00 11.045 0.438 29000. 0.0000116 LE 0.00 20.00 12.566 0.438 29000. 0.0000116 DI 140.00 195.00 0.484 0.626 29000, 0.0000116 DI 120.00 140.00 0.715 0.626 29000. 0.0000116 DI 60.00 120.00 0.484 0.626 29000, 0.0000116 DI 40.00 60.00 0.715 0.626 29000, 0.0000116 DI 0.00 40.00 0.902 0.626 29000. 0.0000116 HO 190.00 195.00 0.484 0.626 29000. 0.0000116 HO 175.00 180.00 0.484 0.626 29000. 0.0000116 HO 155.00 160.00 0.484 0.626 29000. 0.0000116 HO 135.00 140.00 0.715 0.626 29000. 0.0000116 HO 115.00 120.00 0.484 0.626 29000. 0.0000116 FACTORED MEMBER RESISTANCES Page Al ANTENNA LOADING --------- - - - - -- .......ANTENNA....... ATTACHMENT ...........ANTENNA FORCES...... 40651.txt TYPE ELEV AZI RAD AZI AXIAL D 80.0 0.00 0.0 0.0 0.12 0.15 0.02 0.02 D 80.0 0.00 0.0 0.0 0.12 0.15 0.03 0.04 D 60.0 0.00 0.0 0.0 0.13 0.16 0.03 0.03 D 60.0 0.00 0.0 0.0 0.12 0.19 0.04 0.04 D 40.0 0.00 0.0 0.0 0.13 0.19 0.03 0.04 D 40.0 0.00 0.0 0.0 0.12 0.21 0.05 0.05 D 20.0 0.00 0.0 0.0 0.12 0.21 0.04 0.05 D 20.0 0.00 0.0 0.0 0.11 0.23 0.05 0.05 D 0.0 0.00 0.0 0.0 0.11 0.24 0.05 0.04 ANTENNA LOADING --------- - - - - -- .......ANTENNA....... ATTACHMENT ...........ANTENNA FORCES...... AZI TYPE ELEV AZI RAD AZI AXIAL SHEAR GRAVITY TORSION ft ft kip kip kip ft -kip STD+R 185.0 90.0 4.4 120.0 0.13 -0.40 0.24 -0.89 STD +R 185.0 180.0 4.4 240.0 -0.68 0.00 0.24 0.00 SUPPRESS PRINTING ...FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS no yes yes yes .. . . MAXIMUMS..... ALL DISPL MEMBER FOUNDN FORCES LOADS no no no no LOADING CONDITION k 90 mph wind with no ice. Wind Azimuth: 00 PL - 0 MAST LOADING LOAD ELEV APPLY..LOAD..AT TYPE ......FORCES...... RADIUS AZI AZI ft ft VERTICAL C 196.0 0.00 0.0 C 195.0 0.00 0.0 C 195.0 0.00 0.0 C 195.0 0.00 0.0 C 190.0 0.00 0.0 C 187.5 0.00 0.0 C 187.5 0.00 0.0 C 185.0 0.00 0.0 C 180.0 0100 0.0 C 180.0 0.00 0.0 C 180.0 0.00 0.0 C 175.0 0.00 0.0 D 195.0 0.00 0.0 D 180.0 0.00 0.0 D 180.0 0.00 0.0 D 160.0 0.00 0.0 LOAD ......FORCES...... .. .MOMENTS...... AZI HORIZ DOWN VERTICAL TORSNAL kip kip ft-kip ft-kip 0.0 0.02 0.02 0.00 0.00 0.0 0.14 0.01 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.33 0.15 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.09 0.01 0.00 0.00 0.0 0.04 0.01 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.09 0.02 0.00 0.00 0.0 1.36 1.03 0.00 0.00 0.0 0.18 0.14 0.00 0.00 0.0 0.18 0.14 0.00 0.00 0.0 0.08 0.05 0.01 0.00 0.0 0.08 0.05 0.01 -0.01 0.0 0.12 0.07 0.01 0.02 0.0 0.11 0.06 0.01 0.02 Page A3 ANTENNA LOADING .......ANTENNA....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft ..., .ANTENNA FORCES.. .. . AXIAL SHEAR GRAVITY TORSION kip kip kip ft-kip STD +R 185.0 90.0 4.4 120.0 STD +R 185.0 180.0 4.4 240.0 0.03 -0.08 0.81 -0.20 -0.14 0.00 0.81 0.00 SUPPRESS PRINTING ...FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS .MAXIMUMS..... .. ALL DISPL MEMBER FOUNDN FORCES LOADS no yes yes yes no no no no Page AS 40651.txt c 180.0 0.00 0.0 0.0 0.06 0.36 0.00 0.00 c 175.0 0.00 0.0 0,0 0.06 0.36 0.00 0.00 D 195.0 0.00 0.0 0.0 0.03 0.24 0.08 0.00 D 190.0 0.00 0.0 0.0 0.03 0.24 0.08 0.00 D 190.0 0.00 0.0 0.0 0.03 0.21 0.09 0.00 D 185.0 0.00 0.0 0.0 0.03 0.21 0.09 0.00 D 185.0 0.00 0.0 0.0 0.04 0.22 0.11 0.00 D 180.0 0100 0.0 0.0 0.04 0.22 0.11 0.00 D 180.0 0.00 0.0 0.0 0.05 0.33 0.10 0.01 D 175.0 0.00 0.0 0.0 0.05 0.33 0.10 0.01 D 175.0 0.00 0.0 0.0 0.05 0.30 0.10 0.01 D 160.0 0.00 0.0 0.0 0.05 0.30 0.10 0.01 D 160.0 0.00 0.0 0.0 0,05 0.36 0.10 0.01 D 155.0 0.00 0.0 0.0 0.05 0.36 0.10 0.01 D 155.0 0.00 0.0 0.0 0.05 0.32 0.10 0.01 D 140.0 0.00 0.0 0.0 0.05 0.32 0.10 0.01 D 140.0 0.00 0.0 0.0 0.05 0.39 0.10 0.01 D 135.0 0.00 0.0 0.0 0.05 0.39 0.10 0.01 D 135.0 0.00 0.0 0.0 0.05 0.36 0.10 0.01 D 120.0 0.00 0.0 0.0 0.05 0.35 0.10 0.01 D 120.0 0.00 0.0 0.0 0.05 0.38 0.09 0.01 D 115.0 0.00 0.0 0.0 0.05 0.38 0.09 0.01 D 115.0 0.00 0.0 0.0 0.05 0.35 0.09 0.00 D 100.0 0.00 0.0 0.0 0.05 0.36 0.07 0.00 D 100.0 0.00 0.0 0.0 0105 0.38 0.13 0.01 D 80.0 0.00 0.0 0.0 0.05 0.39 0.11 0.01 D 80.0 0.00 0.0 0.0 0.05 0.39 0.17 0.01 D 60.0 0.00 0.0 0.0 0.05 0.40 0.14 0101 D 60.0 0.00 0.0 0.0 0.05 0.44 0.21 0.01 D 40.0 0.00 0.0 0.0 0.05 0.45 0.19 0.01 D 40.0 0.00 0.0 0.0 0.04 0.46 0.24 0.02 D 20.0 0.00 0.0 0.0 0.04 0.47 0.22 0.02 D 20.0 0.00 0.0 0.0 0.04 0.49 0.29 0.02 D 13.3 0.00 0.0 0.0 0.04 0.49 0.29 0.02 D 13.3 0.00 0.0 0.0 0.04 0.52 0.34 0.02 D 6.7 0.00 0.0 0.0 0.04 0.52 0.34 0.02 D 6.7 0.00 0.0 0.0 0.05 0.54 0.38 0.02 D 0.0 0.00 0.0 0.0 0.05 0.54 0.38 0.02 ANTENNA LOADING .......ANTENNA....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft ..., .ANTENNA FORCES.. .. . AXIAL SHEAR GRAVITY TORSION kip kip kip ft-kip STD +R 185.0 90.0 4.4 120.0 STD +R 185.0 180.0 4.4 240.0 0.03 -0.08 0.81 -0.20 -0.14 0.00 0.81 0.00 SUPPRESS PRINTING ...FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS .MAXIMUMS..... .. ALL DISPL MEMBER FOUNDN FORCES LOADS no yes yes yes no no no no Page AS 40651.txt 0. 51 k 0.62 v 190.0 --------------- - - - - -- 0.01 v 0.00 A 1.59 w 0.85 B 185.0 --------------- - - - - -- 0.01 A 0.00 A 4.27 w 2.19 x 180.0 --------------- - - - - -- 0.38 v 0.00 A 9.01 x 3.30 t 175.0 --------------- - - - - -- 0.03 N 0.00 A 16.17 w 3.68 170.0 --------------- - - - - -- 0.01 q 0.00 A 23.82 w 3.93 t 165.0 --------------- - - - - -- 0.03 M 0.00 A 32.44 w 4.20 1 160.0 --------------- - - - - -- 0.23 M 0.00 A 41.31 w 4.44 t 155.0 --------------- - - - - -- 0.05 M 0.00 A 51.62 w 4.75 1 150.0 ---------------- - - - - -- 0.01 AC 0.00 A 61.80 w 4.98 t 145.0 --------------- - - - - -- 0.04 M 0.00 A 73.41 w 5.27 140.0 --------------- - - - - -- 0.40 M 0.00 A 84.69 w 5.64 w 135.0 ------------------ - - --- 0.10 M 0.00 A 98.23 w 5.82 1 130.0 --------------- - - - - -- 0.03 AC 0.00 A 110.76 w 6.11 w 125.0 ------ ,--------- - - - - -- 0.09 M 0.00 A 125.48 w 6.34 1 120.0 ---------------- - - - - -- 1.55 AC 0.00 A 133.41 w 2.52 w 115.0 ---------------- - - - - -- 0.07 M 0.00 A 137.51 w 2.37 e 110.0 --------------- - - - - -- 0.00 AC 0.00 A 139.82 w 2.44 w 105.0 ----------------- -- - - -- 0.05 M 0.00 A 143.78 w 2.36 e 100.0 --------------- - - - - -- 0.00 BB 0.00 A 146.51 w 2.45 w 95.0 --------------- - - - - -- 0.04 M 0.00 A 150.38 w 2.43 e 90.0 ----- ---------- - - - - -- 0.00 o 0.00 A 153.39 w 2.52 w 85.0 -------- -------- - - - - -- 0.03 M 0.00 A 157.23 w 2.55 e 80.0 ---------------- - - - - -- 0.00 0 0.00 A 160.45 w 2.62 w 75.0 --------------- - - - - -- 0.02 M 0.00 A 164.29 w 2.69 e 70.0 --------------- - - - - -- 0.00 0 0.00 A 167.66 w 2.75 w 65.0 --------------- - - - - -- 0.02 M 0.00 A 171.50 w 2.85 e 60.0 ---------------- - - - - -- 0.01 M 0.00 A 174.97 w 2.89 w 55.0 ------------ ---- - - - - -- 0.02 M 0.00 A 178.80 w 3.03 e 50.0 --------------- - - - - -- 0.01 M 0.00 A 182.33 w 3.05 45.0 --------------- - - - - -- 0.02 M 0.00 A 186.17 w 3.22 e 40.0 --------------- - - - - -- 0.02 M 0.00 A 190.33 w 3.41 w Page A7 MAXIMUM INDIVIDUAL FOUNDATION LOADS: (kip) - ------- - - - - -- LOAD - -- COMPONENTS------- - - - - -- TOTAL NORTH EAST DOWN UPLIFT SHEAR 17.78 S 15.69 e 242.80 S - 217.22 w 17.90 e MAXIMUM TOTAL LOADS ON FOUNDATION : (kip & kip -ft) - - - - -- HORIZONTAL - - - -- DOWN --- - - - - -- OVERTURNING--- - - - - -- TORSION NORTH EAST TOTAL NORTH EAST TOTAL @ 119.9 @ 329.7 28.8 -25.8 29.0 81.2 3114.8 - 2828.0 3149.6 -12.3 AC ] AO BT S J P P Page A9 40651.txt 95.0 ----------- - - - - -- - - -- -0.03 AC 0.00 A - 161.59 S -2.40 w 90.0 --------------- - - - - -- 0.00 AQ 0.00 A - 165.13 S -2.58 e 85.0 --------------- - - - - -- -0.03 AC 0.00 A - 169.67 s -2.49 w 80.0 --------------- - - - - -- 0.00 AQ 0.00 A - 173.46 S -2.71 e 75.0 --------------- - - - - -- -0.02 AC 0.00 A - 178.00 5 -2.61 w 70,0 --------------- - - - - -- 0.00 AQ 0.00 A - 181.96 s -2.86 e 65.0 --------------- - - - - -- -0.02 AC 0.00 A - 186.51 S -2.75 w 60.0 --------------- - - - - -- -0.01 AO 0.00 A - 190.65 s -3.03 e 55.0 --------------- - - - - -- -0.02 AC 0.00 A - 195.28 S -2.91 AQ 50.0 --------------- - - - - -- -0.01 AC 0.00 A - 199.54 S -3.21 e 45.0 --------------- - - - - -- -0.02 AC 0.00 A - 204.20 S -3.12 AQ 40.0 --------------- - - - - -- -0.01 AC 0.00 A - 209.28 s -3.62 e 33.3 --------------- - - - - -- -0.02 AC 0.00 A - 215.55 s -3.55 g 26.7 --------------- - - - - -- -0.01 AO 0.00 A - 221.50 S -3.84 e 20.0 --------------- - - - - -- -0.02 AC 0.00 A - 227.79 S -3.79 g 13.3 --------------- - - - - -- 0.00 M 0.00 A - 233.82 S -4.02 e 6.7 --------------- - - - - -- -0.02 AC 0.00 A - 240.05 S -4.00 g 0.0 --- ------------ - - - - -- 0.00 A 0.00 A MAXIMUM INDIVIDUAL FOUNDATION LOADS: (kip) - ------- - - - - -- LOAD - -- COMPONENTS------- - - - - -- TOTAL NORTH EAST DOWN UPLIFT SHEAR 17.78 S 15.69 e 242.80 S - 217.22 w 17.90 e MAXIMUM TOTAL LOADS ON FOUNDATION : (kip & kip -ft) - - - - -- HORIZONTAL - - - -- DOWN --- - - - - -- OVERTURNING--- - - - - -- TORSION NORTH EAST TOTAL NORTH EAST TOTAL @ 119.9 @ 329.7 28.8 -25.8 29.0 81.2 3114.8 - 2828.0 3149.6 -12.3 AC ] AO BT S J P P Page A9 195'53P DT5I BLAIR, NE (40651) 2/24/2011 TRJOHN5TON 180-195 Section 01 Leg IN 01- T1180552 Leg: 1.75 S.R, Gussets: 0.375" thick Bracing ID: 01- T8300021 Nag: L 2 X 2 X 1/8 with 1 bolt at each end Horiz: L 2 X 2 X 1/8 with i bolt at each end Bolts: 0.625" diameter Bottom splice: TW502241 (4) 0,75" splice bolts on a 5.5" bolt circle (plate: 7.5" wide by 0,75" thick) ------------------------------------------------------------------------------------------------------------------ 160-180 Section 01 Top splice: TW502242 (4) 0.75" splice bolts on a 55" bolt circle (plate: TY wide by 0.75" thick Leg ID: 01- T1180608 Leg: 2.0 S.R. Gussets: 0.375" thick Bracing IN 01- T8300029 Diag: L 2 X 2 X 1/8 with 1 bolt at each end Horiz: L 2 X 2 X 1/8 with 1 bolt at each end Bolts: 0.625" diameter Bottom splice: TW502242 (4) 0,75" splice bolts on a 5.5" bolt circle (plate: 7.5" wide by 0.75" thick) - - - - -- ------------------------------------------------------------------------------------------------------ 140-160 Section 01 Top splice: TW502244 (4) 0.75" splice bolts on a 55" bolt circle (plate: 7.5" wide by 1" thick Leg ID: 01- TI180622 Leg: 2.55A Gussets: 0.375" thick Bracing 10: 01- T8300029 [)lag: L 2 X 2 X 1/8 with 1 bolt at each end Horiz: L 2 X 2 X 1/8 with 1 bolt at each end Bolts: 0,625" diameter Bottom splice: TW502280 (6) 1" splice bolts on a 7.25" bolt circle (plate: 9.75" wide by 1" thick) 120-140 Section 01 Top splice: TW502246 (6)1" splice bolts on a 7,25" bolt circle (plate: 9.75" wide by 1.25" thick Leg 1D: 01- T1180632 Leg: 3.0 5,R. Gussets. 0.375" thick Page: 1 of 3 Bracing 11): 01- T$300030 Nag: L 2 X 2 X 3/16 with 1 bolt at each end 195'53R DTSI BLAIR, NE (40651) 2/24/2011 TRJOHNSTON Page: 3 of 3 (6) 1" splice bolts on a 7.25" bolt circle (plate: 9.75" wide by 1.5" thick Leg IN 05- T1180940 Leg: 3.5 S,R. Gussets: 0.375" thick Bracing ID: 05- T8300057 Nag: L 2 X 2 X 3/16 with 1 bolt at each end Bolts: 0,625" diameter Bottom splice: TWS02286 (6) 1.25" splice bolts on a 8,75" bolt circle (plate: 12" wide by 1,5" thick) ----------------------------------------------------------------------------------------------------------------------- 20-40 Section 06 Top splice: TW502249 (6)1.25' splice bolts on a 8.75" bolt circle (plate: 12" wide by 1.75" thick Leg TD: 06- T1181026 Leg: 3.75 5.R. Gussets: 0.5" thick Bracing ID: 06- T8300062 Nag: L 2 1/2 X 2 1/2 X 3/16 with 1 bolt at each end Bolts: 0.75" diameter Bottom splice: TWS02249 (6) 1.25" splice bolts on a 8,75' bolt circle (plate: 12" wide by 1,75" thick) ------------------------------------------------------------------------------------------------------------------------- 0-20 Section 07 Top splice: TWS02250 (6)1,25' splice bolts on a 8,75" bolt circle (plate: 12" wide by 1.75" thick Leg ID: 07- T1181035 Leg: 4,0 S.R. Gussets: 0.5" thick Bracing IN 07- T8300068 Nag: L 2 1/2 X 2 1/2 X 3/16 with 1 bolt at each end Bolts: 0.75" diameter Base plate: TW502402 (6) 1,25" F1554 anchor bolts on a 8.75" bolt circle (plate: 12" wide by 1.75" thick) ------------------------------------------------------------------------------------------------------------------------- Anchor bolts: 040041059 (6) 1.25" bolts, 5' - 3" long -------------------------------------------------------------------- Anchor bolt template: - - - - -- ---------------------------------------------- C30139209 (6) 1.25" bolts on a 8.75' bolt circle MAT FOUNDATION DESIGN BY SABRE TOWERS & POLES (CONTINUED) Two-Way Shear: I is OK 0 Fails Minimum Mat Width I Average d (in) 14.25 Pier Area of Steel �V (kips) EMI M V,, (kips) 1 "242.A:" 1 12 �V. = $(2 + 4/i3j. b,d 600.9 Anchor Bolt Pull-Out 1 �V. =�(cc,,d/b.+2)f.' 637.0 Steel Ratio I �V. = Of.'% d 400.6 Interaction Diagram Visual Check 1 Shear perimeter, b, (in) 130.73 Hook Development P. I Stability. Resisting moment Overturning Design Strength (ft-k) 4680.18 Factored Overturning Moment (ft k) One-Way Shear: �V. (kips) ' ' � flair l l V (kips) F_ 262 .1= Pier Design: Design Tensile Strength (kips) Tu (kips) �V (kips) V (kips) �V,,=�2(1+Nj(500A 29.8 V. (kips) V., max = 4 f,,"'b,d (kips) 182.1 Maximum Spacing (in) 12.00 (Only if Shear Ties are Required) Actual Hook Development (in) 13.50 Reqd Hook Development ldh (in) 11.62 Ref. AC 111. 6. 5 & 11.5.8.3 Anchor Solt Pull-Out: P�, (kips) Pier Rebar Development Length (!n A,# Required Length of Development (in) 27 -T" Flexure in Slab: Wn (ft-kips) '11 M (ft-kips) F,94 �13 L a (in) 1.04 Steel Ratio 0.00413 01 0.85 Maximum Steel Ratio (.7510b) 0.0214 Minimum Steel Ratio 0.0018 Rebar Development in Pad (in) Required Development in Pad (in) Condition I is OK 0 Fails Minimum Mat Width I Maximum Soil Bearing Pressure I Pier Area of Steel Pier Shear Two-Way Shear 1 Overturning I Anchor Bolt Pull-Out 1 Flexure 1 Steel Ratio I Length of Development in Pad I Interaction Diagram Visual Check 1 One-Way Shear Hook Development Minimum Mat Depth I P I A-t I DRILLED STRAIGHT PIER DESIGN BY SABRE TOWERS & POLES (CONTINUED) Uplift: Nominal Skin Friction (kips) 273.3 Wc, Weight of Concrete (kips) 26.1 W Soil Resistance (kips) 1951.8 (Ds(Wr +Wc) (kips) Uplift Design Strength (kips) Pier Design: Design Tensile Strength (kips) �V (kips) �V, =�2(1 +N /(500A (kips) V (kips) Maximum Spacing (in) 1483.4 O w °' :4iii� 14 * ** V max = 4 f, (kips) 12.00 (Only if Shear Ties are Required) * ** Ref. ACI 11.5.5 & 11.5.6.3 Factored Uplift (kips) Tu (kips) V„ (kips) ` . Anchor Bolt Pull -Out: ��'� ��(� � 4AF�.n-r) 1011 ��' H � L ; .,- � P, (kips) ::: Z17:2 . Rebar Development Length (in) >: ` ',,:.` iG squired Length of Development (in ::21:54 Condition 1 is OK, 0 Fails Download 1 Uplift 1 Area of Steel 1 Shear 1 Anchor Bolt Pull -Out 1 Interaction Diagram Visual Check 1 r , A I -�) ! r f ... -Q- T owers • P Structural Design Report 195' S3R Series SD Self- Supporting Tower located at: Blair, NE prepared for: DTSI by: Sabre Towers & Pales TM Job Number: 40551 Revision A May 5, 2011 TowerProfile ..................... ............................... 1 Foundation Design Summary ........ ............................... 2 Maximum Leg Loads ............... ............................... 3 MaximumDiagonal Loads ........... ............................... 4 Maximum Foundation Loads ......... ............................... 5 Calculations ...................... ............................... Al -All Prepared by Approved by I ups, M)OW-24 Sabrom T owers Po No.: 40651 Page: 2 Date: 5!5111 By: REB Revision A Customer: DTSI Site: Blair, NE. 195 ft. Model S3R Series SD Self Supporting Tower At 90 mph Wind with no ice and 50 mph Wind with 0.75 in. Ice per ANSUTIA- 222 -G -2005. Antenna Loading per Page 1 Two (2) #4 ties within top 5" of concrete • r Notes: 1). Concrete shall have a minimum 28 -day compressive strength of 4000 PSI, in accordance with ACE 318 -05. 2). Rebars to conform to ASTM specification A615 Grade 60. 3). All rebar to have a minimum of 3" concrete cover. 4). All exposed concrete corners to be chamfered 3/4 ". 5). The foundation design is based on the geotechnical report by TG project no. 10448.01, dated: 4129111 6). See the geotechnical report for drilled pier installation requirements, if specified. 7). The foundation is based on the following factored loads: Factored uplift (kips) = 217.22 Factored download (kips) = 242.8 Factored shear (kips) = 17.9 Rebar Schedule per Pier (26) #8 vertical rebar w!#4 ties, two (2) Pier within top 5" of pier then 12" C/C Information contained herein is the sole property of Sabre Towers & Poles, constitutes a trade secret as defined by Iowa Code Ch. 550 and shall not be reproduced, copied or used in whole or part for any purpose whatsoever without the prior written consent of Sabre Towers & Poles. 2101 Murray St - P.O. Box 658 - Sioux City, IA 51102 -0658 - Phone 712.258.6690 - Fax 712.258.8250 rawReaults, Copyright (C) Guymast Inc. 2010 Phone: (416) 736-745 24 feb 2011 ,icensed to: Sabre Communications Corporation 11:44:16 Maximum Lev (f t) 295.0 190 180 1 260 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 Compression in Diagonals (kip) Tension in Diagonals (kip) 1 .5 5 2.5 0 2.5 5 7.5 10.2- 5 4.5- -4. 9 f 4.9- -4. -6.6 7.5 5 2.5 ?roject: C; \Output\ S3RSD\40 651 MST 0 2.5 5 7A 195.0 190 180 170 160 ISO 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 page 4 40651. txt MAST ^ - Latticed Tower Analysis Y (unguyed)_ (c)1997�Guymast ^ Inc. 416 - 736 --7453 Processed under license at: Sabre Communications Corporation on: 24 feb 2011 at: 11:39:51 MAST GEOMETRY ( ft ) PANEL NO.OF ELEV.AT ELEV.AT F.W..AT F.W..AT TYPICAL TYPE LEGS BOTTOM TOP BOTTOM TOP PANEL HEIGHT x 3 190.00 195.00 5.00 5.00 5.00 x 3 180.40 190.00 5.00 5.00 5.00 x 3 175.00 180.00 5.00 5.00 5.00 x 3 160.00 175.00 5.00 5.00 5.00 x 3 155.00 160.00 5.00 5.00 5.00 x 3 140.00 155.00 5.00 5.00 5.00 x 3 135.00 140.00 5.00 5.00 5.00 x 3 120.00 135.00 5.00 5.00 5.00 x 3 115.00 120.00 5.44 5.00 5.00 x 3 100.00 115.00 6.75 5.44 5.00 x 3 80.00 100.00 8.50 6.75 5.00 x 3 60.00 80.00 10.25 8.50 5.00 x 3 40.00 60.00 12.00 10.25 5.00 x 3 20.00 40.00 13.75 12.00 6.67 x 3 0.00 20.00 15.50 13.75 6.67 MEMBER PROPERTIES MEMBER BOTTOM TOP x -SECTN RADIUS ELASTIC THERMAL TYPE ELEV ELEV AREA OF GYRAT MODULUS ExPANSN ft ft in.sq in ksi /deg LE 180.00 195.00 2.405 0.438 29000. 0.0000116 LE 160.00 180.00 3.142 0.438 29000. 0.0000116 LE 140.00 160.00 4.909 0.438 29000. 0.0000116 LE 100.00 140.00 7.069 0.438 29000. 0.0000116 LE 60.00 100.00 8.296 0.438 29000. 0.0000116 LE 40.00 60.00 9.621 0.438 29000, 0.0000116 LE 20.00 40.00 11.045 0.438 29000. 0.0000116 LE 0.00 20.00 12.566 0.438 29000. 0.0000116 DI 140.00 195.00 0.484 0.626 29000. 0.0000116 DI 120.00 140.00 0.715 0.626 29000. 0.0000116 DI 60.00 120.00 0.484 0.626 29000, 0.0000116 DI 40.00 60.00 0.715 0.626 29000, 0.0000116 DI 0.00 40.00 0.902 0.626 29000. 0.0000116 HO 190.00 195.00 0.484 0.626 29000. 0.0000116 HO 175.00 180.00 0.484 0.626 29000. 0.0000116 HO 155.00 160.00 0.484 0.626 29000. 0.0000116 HO 135.00 140.00 0.715 0.626 29000. 0.0000116 HO 115.00 120.00 0.484 0.676 29000. 0.0000116 FACTORED MEMBER RESISTANCES Page Al D 80.0 D 80.0 D 50.0 D 60.0 D 40.0 D 40.0 D 20.0 D 20.0 D 0.0 ANTENNA LOADING ... ..ANTENNA...... TYPE ELEV AZI ft STD +R 185.0 90.0 STD +R 185.0 180.0 SUPPRESS PRINTING ATTACHMENT ...........ANTENNA FORCES.......... RAD AZI AXIAL SHEAR 40551.txt TORSION ft kip 0.00 010 0.0 0.12 0.15 0.02 0.02 0.00 010 0.0 0.12 0.15 0.03 0.04 0100 0.0 0.0 0.13 0.16 0.03 0.03 0.00 0.0 0.0 0.12 0.19 0.04 0.04 0.00 0.0 0.0 0.13 0.19 0.03 0.04 0.00 0.0 0.0 0.12 0.21 0.05 0.05 0.00 0.0 0.0 0.12 0.21 0.04 0.05 0.00 0.0 0.0 0.11 0.23 0.05 0.05 0.00 0.0 0.0 0.11 0.24 0.05 0.04 ... ..ANTENNA...... TYPE ELEV AZI ft STD +R 185.0 90.0 STD +R 185.0 180.0 SUPPRESS PRINTING ATTACHMENT ...........ANTENNA FORCES.......... RAD AZI AXIAL SHEAR GRAVITY TORSION ft kip kip kip ft-kip 4.4 120.0 0.13 -0.40 0.24 -0.89 4.4 240.0 -0.68 0100 0.24 0.00 ...FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS no yes yes yes .MAXIMUMS. .. .. ALL DISPL MEMBER FOUNDN FORCES LOADS no no no no LOADING CONDITION k 90 mph wind with no ice. wind Azimuth: On PL - 0 MAST LOADING LOAD ELEV APPLY..LOAD..AT TYPE .. . . FORCES.. RADIUS AZI AZI ft ft VERTICAL C 195.0 0.00 0.0 C 195.0 0.00 0.0 C 19510 0.00 0.0 C 19510 0.00 0.0 C 190.0 0.00 010 C 187.5 0.00 0.0 C 187.5 0.00 0.0 C 185.0 0.00 0.0 C 180.0 0.00 0.0 C 180.0 0.00 0.0 C 180.0 0100 0.0 C 175.0 0.00 0.0 D 195.0 0.00 0.0 D 180.0 0,00 0.0 D 180.0 0100 0.0 D 160.0 0.00 0.0 LOAD .. . . FORCES.. .. .MOMENTS... . AZI HORIZ DOWN VERTICAL TORSNAL kip kip ft-kip ft-kip 0.0 0.02 0.02 0.00 0.00 0.0 0.14 0.01 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.33 0.15 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.09 0.01 0.00 0.00 0.0 0.04 0.01 0.00 0.00 0.0 0.19 0.14 0.00 0.00 0.0 0.09 0.02 0.00 0.00 0.0 1.36 1.03 0.00 0.00 0.0 0.18 0.14 0.00 0.00 0.0 0.18 0.14 0.00 0.00 0.0 0.08 0.05 0.01 0.00 0.0 0.08 0.05 0.01 -0.01 0.0 0.12 0.07 0.01 0.02 0.0 0.11 0.06 0.01 0.02 Page A3 ANTENNA LOADING ......ANTENNA....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft .... .ANTENNA FORCES.. .. AXIAL SHEAR GRAVITY TORSION kip kip kip ft -kip STD +R 185.0 90.0 4.4 120.0 STD +R 185.0 180.0 4.4 240.0 0.03 -0.08 0.81 -0.20 -0.14 0.00 0.81 0.00 SUPPRESS PRINTING ..FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS .. . .MAXIMUMS..... ALL DISPL MEMBER FOUNDN FORCES LOADS no yes yes yes no no no no Page A5 44651. txt C 180.0 0.00 0.0 0.0 0.06 0.36 0.00 0.00 C 175.0 0,00 0.0 0.0 0,06 0.36 0.00 0.00 D 195.0 0.00 0.0 0.0 0.03 0.24 0.08 0.00 D 19010 0.00 0.0 0.0 0.03 0.24 0.08 0.00 D 190.0 0.00 0.0 0.0 0.03 0.21 0.09 0.00 D 185.0 0.00 0.0 0.0 0.03 0.21 0.09 0.00 D 185.0 0.00 0.0 0.0 0.04 0.22 0.11 0.00 D 180.0 0.00 0.0 0.0 0.04 0.22 0.11 0.00 D 180.0 0.00 0.0 0.0 0.05 0.33 0.10 0.01 D 175.0 0.00 0.0 0.0 0.05 0.33 0.10 0.01 D 175.0 0.00 0.0 0.0 0.05 0.30 0.10 0.01 D 160.0 0,00 0.0 0.0 0.05 0.30 0.10 0.01 D 160.0 0.00 0.0 0.0 0.05 0.36 0.10 0.01 D 155.0 0,00 0.0 0.0 0.05 0.36 0110 0.01 D 155.0 0.00 0.0 0.0 0.05 0.32 0.10 0.01 D 140.0 0.00 0.0 0.0 0.05 0.32 0.10 0.01 D 140.0 0.00 0.0 0.0 0.05 0.39 0.10 0.01 D 135.0 0.00 0.0 0.0 0.05 0.39 0.10 0.01 D 135.0 0.00 0.0 0.0 0.05 0.36 0.10 0.01 D 120.0 0.00 0.0 0.0 0.05 035 0.10 0.01 D 120.0 0.00 0.0 0.0 0.05 0.38 0.09 0.01 D 115.0 0.00 0.0 0.0 0.05 0.38 0109 0.01 D 115.0 0.00 0.0 0.0 0.05 0.35 0.09 0.00 D 100.0 0,00 0.0 0.0 0.05 0.36 0.07 0.00 D 100.0 0.00 0.0 0.0 0.05 0.38 0.13 0.01 D 80.0 0.00 0.0 0.0 0.05 0.39 0.11 0.01 D 80.0 0100 0.0 0.0 0.05 0.39 0.17 0.01 D 60.0 0.00 0.0 0.0 0.05 0.40 0.14 0.01 D 60.0 0.00 0.0 0.0 0.05 0.44 0.21 0.01 D 40.0 0.00 0.0 0.0 0.05 0.45 0.19 0.01 D 40.0 0.00 0.0 0.0 0.04 0.46 0.24 0.02 D 20.0 0.00 0.0 0.0 0.04 0.47 0.22 0.02 D 20.0 0.00 0.0 0.0 0.04 0.49 0.29 0.02 D 13.3 0.00 0.0 0.0 0.04 0.49 0.29 0.02 D 13.3 0.00 0.0 0.0 0.04 0.52 0.34 0.02 D 6.7 0.00 0.0 0.0 0.04 0.52 0.34 0.02 D 6.7 0.00 0.0 0.0 0.05 0.54 0.38 0.02 D 0.0 0.00 0.0 0.0 0.05 0.54 0.38 0.02 ANTENNA LOADING ......ANTENNA....... ATTACHMENT TYPE ELEV AZI RAD AZI ft ft .... .ANTENNA FORCES.. .. AXIAL SHEAR GRAVITY TORSION kip kip kip ft -kip STD +R 185.0 90.0 4.4 120.0 STD +R 185.0 180.0 4.4 240.0 0.03 -0.08 0.81 -0.20 -0.14 0.00 0.81 0.00 SUPPRESS PRINTING ..FOR THIS LOADING.. LOADS DISPL MEMBER FOUNDN INPUT FORCES LOADS .. . .MAXIMUMS..... ALL DISPL MEMBER FOUNDN FORCES LOADS no yes yes yes no no no no Page A5 40651.txt 0. 51 k 0.62 v 190.0 --------------- - - - - -- 0.01 v 0.00 A 1.59 w 0.85 B 185.0 --------------- - - - - -- 0.01 A 0.00 A 4.27 w 2.19 x 180.0 ---------------- - - - -- 0.38 v 0.00 A 9.01 x 3.30 t 175.0 --- --------------- - - - - -- 0.03 N 0.00 A 16.17 w 3.68 J 170.0 --------------- - - - - -- 0.01 q 0.00 A 23.82 w 3.93 t 165.0 --------------- - - - - -- 0.03 M 0.00 A 32.44 w 4.20 3 160.0 ------ ---------- - - - - -- 0.23 M 0.00 A 41.31 w 4.44 t 155.0 ---------------- -- - -- 0.05 M 0.00 A 51.62 w 4.75 1 150.0 - ----------- --- - - - - -- 0.01 AC 0.00 A 61.80 w 4.98 t 145.0 --------------- - - - - -- 0.04 M 0.00 A 73.41 w 5.27 J 140.0 --------------- - - - - -- 0.40 M 0.00 A 84.69 w 5.64 w 135.0 ---------------- - - - - -- 0.10 M 0.00 A 98.23 w 5.82 1 130.0 --------------- - - - - -- 0.03 AC 0.00 A 110.76 w 6.11 w 125.0 --------------- - - - - -- 0.09 M 0.00 A 125.48 w 6.34 J 120.0 - -------------- - - - - -- 1.55 AC 0.00 A 133.41 w 2.52 w 115.0 --------------- - - - - -- 0.07 M 0.00 A 137.51 w 2.37 e 110.0 ---------------- - - - - -- 0.00 AC 0.00 A 139.82 w 2.44 w 105.0 ----- ---------- - - - - -- 0.05 M 0.00 A 143.78 w 2.36 e 100.0 --------------- - - - - -- 0.00 BB 0.00 A 146.51 w 2.45 w 95.0 --------------- - - - - -- - 0.04 M 0.00 A 150.38 w 2.43 e 90.0 --------------- - - - - -- 0.00 0 0.00 A 153.39 w 2.52 w 85.0 --------------- - - - - -- 0.03 M 0.00 A 157.23 w 2.55 e 80.0 --------------- - - - - -- 0.00 0 0.00 A 160.45 w 2.62 w 75.0 ---------------- - - - - -- 0.02 M 0.00 A 164.29 w 2.69 e 70.0 --------------- - - - - -- 0.00 0 0.00 A 167.66 w 2.75 w 65.0 ---------------- - - - - -- 0.02 M 0.00 A 171.50 w 2.85 e 6010 ---------------- - -- - -- 0.01 M 0.00 A 174.97 w 2.89 w 55.0 --------------- - - - - -- 0.02 M 0.00 A 178.80 w 3.03 e 50.0 ---------------- - - - - -- 0.01 M 0.00 A 182.33 w 3.05 w 45.0 --------------- - - - - -- 0.02 M 0.00 A 186.17 w 3.22 e 40.0 --------------- - - - - -- 0.02 M 0.00 A 190.33 w 3.41 w Page A7 MAXIMUM INDIVIDUAL FOUNDATION LOADS: (kip) -------- - - - - -- LOAD -- COMPONENTS------- - - - - -- TOTAL NORTH EAST DOWN UPLIFT SHEAR 17.78 S 15.69 a 242.80 S - 217.22 w 17.90 e MAXIMUM TOTAL LOADS ON FOUNDATION : (kip & kip -ft) - - - - -- HORIZONTAL----- DOWN --- - - - - -- OVERTURNING--- - - - - -- TORSION NORTH EAST TOTAL NORTH EAST TOTAL @ 119.9 @ 329.7 28.8 -25.8 29.0 81.2 3114.8 - 2828.0 3149.6 -12.3 AC J AO BT 5 J P P Page A9 40651.txt 95.0 ------ ------ --- - - - - -- -0.03 AC 0.00 A - 161.59 S -2.40 w 90.0 --------------- - - - - -- 0.00 AQ 0.00 A - 165.13 5 -2.58 e 85.0 --------------- - - - - -- -0.03 AC 0.00 A - 169.67 S -2.49 w 80.0 --------------- - - - - -- 0.00 AO 0.00 A - 173.46 S -2.71 e 75.0 --------------- - - - - -- -0.02 AC 0.00 A - 178.00 S -2.61 w 70.0 -------- ------- - - - - -- 0.00 AQ 0.00 A - 181.96 5 . -2.86 e 65.0 --------------- - - - - -- -0.02 AC 0.00 A - 186.51 S -2.75 w 60.0 --------------- - - - - -- -0.01 AO 0.00 A - 190.65 S -3.03 e 55.0 --------------------- -0.02 AC 0.00 A - 195.28 S -2.91 AQ 50.0 --------------- - - - - -- -0.01 AC 0.00 A - 199.54 5 -3.21 e 45.0 --------------- - - - - -- -0.02 AC 0.00 A - 204.20 S -3.12 AQ 40.0 --------------- - - - - -- -0.01 AC 0.00 A - 209.28 5 -3.62 e 33.3 --------------- - - - - -- -0.02 AC 0.00 A - 215.55 S -3.55 g 25.7 --------------- - - - - -- -0.01 AO 0.00 A - 221.50 S -3.84 e 20.0 --------------- - - - - -- -0.02 AC 0.00 A - 227.79 S -3.79 g 13.3 --------------- - - - - -- 0.00 M 0.00 A - 233.82 S -4.02 e 6.7 --------------- - - - - -- -0.02 AC 0.00 A - 240.05 S -4.00 g 0.0 --------------- - - - - -- 0.00 A 0.00 A MAXIMUM INDIVIDUAL FOUNDATION LOADS: (kip) -------- - - - - -- LOAD -- COMPONENTS------- - - - - -- TOTAL NORTH EAST DOWN UPLIFT SHEAR 17.78 S 15.69 a 242.80 S - 217.22 w 17.90 e MAXIMUM TOTAL LOADS ON FOUNDATION : (kip & kip -ft) - - - - -- HORIZONTAL----- DOWN --- - - - - -- OVERTURNING--- - - - - -- TORSION NORTH EAST TOTAL NORTH EAST TOTAL @ 119.9 @ 329.7 28.8 -25.8 29.0 81.2 3114.8 - 2828.0 3149.6 -12.3 AC J AO BT 5 J P P Page A9 DRILLED STRAIGHT PIER DESIGI Uplift: Nominal Skin Friction (kips) We, Weight of Concrete (kips) Ws, Soil Resistance (kips) 4)s(Wr+Wc) (kips) 4 BY SABRE TOWERS & POLES (CONTINUED) 226.9 128.8 2949.1 2308.4 Uplift Design Strength (kips) MW Factored Uplift (kips) Pier Design: Design Tensile Strength (kips) Tu (kips) � V (kips) V,, (kips) 1. -2 .. �V,,=X2(1+N,/(500A0))f`,. 112 b,d (kips) 398.3 V. (kips) *** V, max = 4 f j (kips) F 704 1� h'i l i4ffi l I Maximum Spacing (in) 6.54 (Only if Shear Ties are Required) Ref. ACI 11.5.5 & 11,5.6.3 Anchor Bolt Pull-Out: 112 f. 0, Ig P, (kips) 217.2 �P.=�k(213) ( 4 AFLAT) Rebar Development Length (in) '§p" equired Length of Development (in Condition 1 is OK, 0 Fails Download Uplift Area of Steel Shear Anchor Bolt Pull-Out Interaction Diagram Visual Check p , A.0 AM 3 Thiele Geotech Inc Geotechnical Exploration Report • Prepared for: Union Pacific Railroad - Denver 1400 West 52 Avenue Denver, Colorado 80221 April 29, 2011 TG Project No. 10448.01 C 1 I/ JOHN A. CHRISTIANSEN O E-7821 FTJ THIELE GEOTECH, INC. 13478 Chandler Road Omaha, Nebraska 68138 -3716 402.556.2171 Fax 402.556.7831 www.fhielegeotech.com M EM GEOTECHNICAL B MATERIAL E3 ENVIRONMENTAL R ENGINEERING Geotechnical Exploration Report April 29, 2011 TG #10448.01 Page 1 INTRODUCTION Thiele Geotech, Inc. has completed a geotechnical exploration study for the proposed Blair Sub Alternate Microwave Site to be located near the intersection of County Road 26 and County Road 29 in Blair, Nebraska. The purpose of this study was to identify the general soil and ground water conditions underlying the site; to evaluate engineering properties of the existing soils; to provide earthwork and site preparation recommendations; and to recommend design criteria and parameters for the tower foundation. This study included a single soil boring, laboratory testing, and engineering analysis.. The field and laboratory data are presented in the Appendix, along with a description of investigative methods. The drilling and testing performed for this study were conducted solely for geotechnical analysis. No analytical testing or environmental assessment has been conducted. Any statements or observations in this report regarding odors, discoloration, or suspicious conditions are strictly for the information of our client. If an evaluation of environmental conditions is desired, a separate environmental assessment should be conducted. This study did not include biological assessment (e.g. mold, fungi, bacteria) or evaluation of measures for their control. It should also be noted that this report was prepared for design purposes only, and may not be sufficient for a contractor in bid preparation. Prospective contractors should evaluate potential construction problems on the basis of their own knowledge and experience in the local area and on similar projects, taking into account their own intended construction methods and procedures. This report is an instrument of service prepared for use by our client on this specific project. The report may be duplicated as necessary and distributed to those directly associated with this project, including members of the design team and prospective contractors. However, the technical approach and report format shall be considered proprietary and confidential, and this report may not be distributed in whole or in part to any third party not directly associated with this project. By using and relying on this report, all other parties agree to the same terms, conditions, and limitations to which the client has agreed. T h 1 e I e G e o t e c h I n c Geotechnical Exploration Report April 29, 2011 TG #10448.01 Page 3 SURFACE AND SUBSURFACE CONDITION •1 6 MI The site is located in a rural agricultural area between the towns of Kennard and Blair. Where the microwave tower will be constructed the site is fairly flat and level. It appears that this area has recently been filled. The ground surface was bare dirt at the time of drilling. LOCAL GEOLOGY The surface geology of eastern Nebraska is Pleistocene in age and consists of eolian (wind - blown) deposits of Peoria and Loveland loess. The loess formed in dune - shaped hills west of the Missouri River. The Peoria loess typically consists of silty lean clays that are stiff when dry but become softer with increasing moisture content. The Peoria often exhibits low unit weight and is collapse susceptible. The Loveland loess is an older deposit, and typically consists of lean clays. The Loveland generally exhibits higher unit weights and shear strengths than the Peoria. The loess overlies Pleistocene glacial deposits of Kansan and Nebraskan till. The till consists of lean to fat clays mixed with sand, gravel, and occasional cobbles. The glacial deposits are generally fairly deep, but are sometimes near the surface at lower elevations on steep slopes. Cretaceous sandstone or Pennsylvanian limestone and shale form the bedrock unit below the glacial deposits. The depth to bedrock is normally great, and rock is rarely encountered in construction. Along drainageways, alluvial and colluvial deposits are typically present. These soils were formed by erosion of the adjoining loess- mantled hills. Alluvial deposits are generally present along creeks and in major drainageways. The upper several feet of alluvium are usually stiffer due to the effects of desiccation. Colluvial soils are usually located at the base of steep slopes and in upland draws, and are formed by local creep and sloughing. The soils encountered in the test boring generally consisted of man - placed fill over alluvium. The fill was found in the upper 13 feet of the boring and was described as light brown and dark grayish brown, moist to wet, firm to soft lean clay. The fill varied in compaction from 75 percent to 100 percent of an assumed Standard Proctor and contained tree roots. Alluvium was found below the fill and to the bottom of the boring. It was described as dark gray and gray, wet, soft to very soft lean clay. T h i e I e G e o t e c h I n c Geotechnical Exploration Report April 29, 2011 TG #10448.01 Page 5 ANALYSIS AND RECOMMENDATIONS C LT T! Soil in our boring consists of approximately 6 feet of firm lean clay overlying soft to very soft lean clay. No sand or rock was encountered in our boring. The man - placed fill had tree roots in it, and becomes wet and soft at a depth of 6 feet below grade. This fill is poorly suited for supporting a shallow mat foundation. We recommend that a drilled pier be used. Due to the wet and soft soil conditions in the boring, we expect the pier hole to cave if it is not supported open by casing or drilling slurry. DRILLED PIER FOUNDATION For use in determining pier capacities we estimate the following soil properties. 0' to 4' lean clay, ignore due to seasonal climatic effects. 4' TO 50' (lean clay fill & alluvium) • cohesion = 400 psf • internal friction angle 0 degrees • allowable lateral bearing (equivalent fluid for ''/2" lateral deflection, UBC Method) = 100 pcf • horizontal soil modulus factor (for use with elastic method) (Kh) = 25 tsf • allowable skin friction = 140 psf • allowable end bearing = 1,200 psf • soil moist unit weight = 115 pcf No safety factors have been applied to the cohesion, friction angle, or horizontal soil modulus. It is important to note that the horizontal soil modulus is in units of tons per square foot. To convert to tons per cubic foot it is necessary to divide the horizontal soil modulus value by the width of the member (or diameter for round members). For the skin friction capacity an alpha factor of 0.7 and a safety factor of two was applied. A safety factor of three was applied to the allowable end bearing value. Drilled pier excavations should be observed by an experienced geotechnical engineer to evaluate the suitability of the bearing material. Should isolated areas of unsuitable material be encountered at planned depths, it will be necessary to deepen the drilled piers to suitable bearing material. The base of pier excavations should be free of water and loose material prior to placement of concrete. Total settlements of less than one inch are anticipated for the proposed drilled pier foundation supported in approved bearing materials. T h 1 e I e G e o t e c h I n c Geotechnical Exploration Report TG #10448.01 April 29, 2011 Page 7 SEISMIC SITE CLASS Seismic structural design requirements are dictated by a site classification based on average soil properties within the top 100 feet. Based on our local experience, the soil profile was estimated below the maximum boring depth. The average undrained shear strength was then estimated based on the actual laboratory testing and on assumed soil properties for the deeper soil profile. The site classifies as Site Class D (stiff soil profile) according to Table 1613.5.2 of the 2009 International Building Code. OTHER RECOMMENDATIONS During detailed design, additional issues may arise and possible conflicts may occur with our recommendations. Such issues and conflicts should be resolved through dialogue between the geotechnical engineer and designers. It is recommended that the geotechnical engineer review the final design, including the plans and specifications, to verify that our recommendations are properly interpreted and incorporated into the design. If any changes are made in the design of the project, including the nature or location of proposed facilities on the site or significant elevation changes, the analysis and recommendations of this report shall not be considered valid unless the changes are reviewed. The analysis and recommendations of this report should not be applied to different projects on the same site or to similar projects on different sites. The analysis and recommendations in this report are based upon borings at specific locations. The nature and extent of variation between boring locations is impossible to predict. Because of this, geotechnical recommendations are preliminary until they have been confirmed through observation of site excavation and earthwork preparation. If variations appear during subsequent exploration or during construction, we may reevaluate our recommendations and modify them, if appropriate. The geotechnical engineer should be retained during construction to observe compliance with the recommendations of this report and to provide quality control testing of earthwork construction. T h 1 e I e G e o t e c h 1 n c Geotechnical Exploration Report TG #10448.01 April 29, 2011 Appendix Subsurface Exploration Methods Legend of Terms Boring Location Plan Boring Log Soil Test Summary T h i e I e G e o t e c h I n c O 3 pC i 2 Thiele Geotech Inc �' Soil Description Terms Consistency - Fine Grained Consistency - Coarse Grained Moisture Conditions Very Soft, Soft, Firm, Very Loose, Loose, Medium Dry, Slightly Moist, Moist Hard, Very Hard Dense, Dense, Very Dense Very Moist, Wet (Saturated) Sample ape U -- Undisturbed (Shelby Tube) S -- Split barrel (disturbed) C -- Continuous sample A -- Auger cuttings (disturbed) Sample Data No. -- Number SPT -- Standard penetration test bpf -- blows per foot Rec -- Recovery Laboratory Data MC -- Moisture content 7d -- Dry unit weight q„ -- Unconfined compression LL /PI -- Liquid limit & plasticity index 11nifiPrl Snil rinccifir_atinn SvctPm Peat Pt Highly organic soils Clay - Liquid Limit > 50 * Silt - Liquid Limit > 50 * Clay - Liquid Limit < 50 * Silt - Liquid Limit < 50 Silty Clay * 50% or more smaller than No. 200 sieve Fat Clay CH Elastic Silt MH Lean Clay CL Silt ML Siltv Cla CL -ML Clayey Sand SC Sands with 12 to 50 percent smaller than No. 200 sieve More than 50% larger than No. 200 sieve and % sand > % Gravel Silty Sand SM Poorly-Graded Sand with Clay SP -SC Sands with 5 to 12 percent smaller than No. 200 Sieve * Poorly-Graded Sand with Silt SP -SM Well- Graded Sand with Clay ** SW -SC Well- Graded Sand with Silt ** SW -SM Poorly-Graded Sand SP Sands with less than 5 percent smaller than No. 200 sieve * Well- Graded Sand ** SW Clayey Gravel GC Gravels with 12 to 50 percent smaller than No. 200 Sieve More than 50% larger than No. 200 sieve and % gravel > % sand Silty Gravel GM Poorly-Graded Gravel with Clay GP -GC Gravels with 5 to 12 percent smaller than No. 200 sieve * Poorly-Graded Gravel with Silt GP -GM Well- Graded Gravel with Clay ** GW -GC Well- Graded Gravel with Silt ** GW -GM Poorly-Graded Gravel GP Gravels with less than 5 percent smaller than No. 200 sieve Well- Graded Gravel ** GW * See Plasticity Chart for definition of silts and clays ** See Criteria for Sands and Gravels for definition of well - graded Ali Plasticlt / Chart CH or OF MH or OH CL or OL� ML 30 40 50 60 70 Liquid Limit Criteria for Sands and Gravels x 50 m v 40 30 w 20 a 10 T "" Thiele G eotec,h Inc O I N LO WATER LEVEL OBSERVATIONS PROJECT DRILLER LOGGER JOB NO. DATE During Drilling 16.5' Blair Sub Alternate Microwave Site Epley Matychuk 10448.01 4/18/11 End of Drilling 5.8' LOCATION DRILLING METHOD DRILL RIG BORING NO. CR 26 & CR 29, Blair, NE 3.25" HSA CME 55HT B -1 LOCATION OF BORING TYPE OF SURFACE ELEVATION DEPTH boring backfilled with cuttings see Boring Location Plan bare ground 50' VISUAL /MANUAL DESCRIPTION SAMPLE DATA LABORATORY DATA DEP (ft.) COLOR MOIST. CONSIST, SOIL TYPE GEOLOGIC ORIGIN REMARKS NO & TYPE SPT (bpf) REC (in.) MC ( /o) yd (pcf) q„ (tsf) LL/PI CLASS Dft ) 5 light brown moist firm lean clay fill roots roots large roots 5 U -1 10 23.4 103.1 very moist U -2 11 24.4 100.0 1.60 LL =39 PI =16 CL 10 10 wet soft dark grayish brown U -3 12 45.1 77.5 0.57 15 15 dark graV wet soft lean clay alluvium minor calcium residue to 25' U -4 12 47.0 73.9 0.37 o 20 U -5 12 36.8 85.3 0.48 LL =45 PI =28 CL gray 5 25 very soft 1-6 12 37.9 83.4 0.23 f s Vii^ 4 � rx 13 } Aft /i®® PA A■ 1 NNN A ~ im, ._ Thiele o-tech ino a 'L r F-01 auevi'VIP%F% Project Job No. Blair Sub Alternate Microwave Site 10448.01 Location Date CR 26 & CR 29, Blair, NE 4/2612011 B -1 U -1 0.5 -2 23.4 127.3 103.1 0.634 100 U -2 3.5 -5 2.85 24.4 124.4 100.0 0.684 96 1.60 7.7 39 23 16 CL U -3 8.5 -10 2.85 45.1 112.4 77.5 1.175 100 0.57 1.5 U-4 13.5 -15 2.85 47.0 108.6 73.9 1.280 99 0.37 4.6 U -5 18.5 -20 2.85 36.8 116.7 85.3 0.975 100 0.48 10.0 45 17 28 CL U -6 23.5 -25 2.85 37.9 115.0 83.4 1.020 100 0.23 14.6 U -7 28.5 -30 2.85 34.1 114.9 85.7 0.967 95 0.34 15.0 U -8 33.5 -35 2.85 39.1 112.7 81.0 1.079 98 0.29 7.4 U -9 38.5 -00 2.85 35.6 116.1 85.6 0.968 99 0.42 11.6 U -10 43.5A5 2.85 39.0 117.6 84.6 0.991 100 0.63 15.0 47 17 30 CL U -11 48.5 -50 2.85 41.2 110.6 78.3 1.152 97 0.52 14.0