20150608105737659_0001.tif I
i
JUN, 5.2Q15 4;08PM NASTASE ROOFING N0.8582 P. 5
,
INTERNATIONAL 1 I
i
CITY C. r REROOFING
Return to Blair City Hall prior to Final Inspection
218 S 1 street, Blair, NE 88008
Because of limitations caused by the infeasibility to perform detailed inspections which would
not interfere with reroofing work, please indicate compliance with the foilowing requirements
followinci this reroofing job. 9
Property Address: • x.(.9 q +�'• 6`6,6
Contractor or Homeowner (if self} : of z.,a
Permim
installation pate:
YES NO
The materials and methods of application used for recovering or replacing the sAsting
roof covering comply with the requirements of the building code. (8907.9)
• I
❑ ICE PROTECTION INSTALLED: An ice barrier that consists of at least two layers of
underlayment or of a self - adhering polymer modified bitumen sheet was installed and
extends at least from the eave's edge to a point at feast 24 inches insida . the exterior
wall line of the building. (8905.2.7.9)
I� S fRUCTURAL COMPONENTS ARE SOUND: The structural roof components are
capable of supporting the roof covering system and the material and equipment loads
that will be encountered during installation of the roof covering system. (R907.2)
EXISTING COVERING WA S REMOVED: Existing roof covering was removed for one
of the reasons required by section 8907,3
DID NOT USE RUSTizD Mi;TAL OR ]=LASHING; Existing vent flashing, - metal edges, _. .
drain outlets, Dollars or metal counter - flashing were not reinstalled If rusted. (1907.5)
E fi LA G INSTALLED PROPERLY: Flashing shR11 be reconstructed in accordance
ZLbil tumalnous manufacturer's installation instructions. Metal flashing to which
aterials are to be adhered shall be primed prior to installation. (R907.8)
_ I
sigKat ur of Primary Installer Date
69 — 6
7 arure of Permff Holder Date
i