Checkoff Sheet MS-2015-00160.tif 2009. INTERNATIONAL RESIDENTIAL CODE
CITY OF 13LAM. REROO . 9 ..CHECKOF .'SH8ET
Returnito BlairCity I 1o> °, , w 1 . , � o
' � th Street lair, 0
Because of limitations caused by the .infeasibility to parf6rM detailed inspections which woo
Id
not interfere with reroofing work, please c with the fo llowing 'requiremants
follo�nrinc� this reroofing job.
i
P r operty Address �.
Contractor or Homeowner (if self)
lei
Permit #s Ms-2014-
Installation bate:. .
YES NO
The materials and methods of application used for recovering or replacing the existing
roof covering comply with the. requirements of the building code. `' (R907':1).;
ICE PROTECTION INSTAL LEI ; An lee barrier that consists of at least two layers of
underlayment or of a self-adhering polymer modified bitumen sheet was installed and
i
extends at le ast from the eavds edge to .a paint at least 24 inches inside the exterior
wall line of the building. (R005.2.7.1),
STRUCTURAL. COMPONENTS ARE SOUND's The structural roof components are
capable of supporting the roof covering system and the mater .and gquipm loads
that will be encountered durind installation of the, roof covering, system. (8907 >2)
EXISTING COVERING INCAS REMOVED Q Existing roof covering was'removed for one.
of the reasons required by section R907 ;
DID NOT USE RUSTED METAL OR FLA HIND. Existing vent fiashingg imetal edges,
drain outrats, collars or metal counter- flashing were not reinstalled if rusted.,(R907 5)
FWHINC INSTALLED PR0PEgL,'Y:' Flashing shall be reconstructed in accordance
with approved manufacturer's installation instructions, fetal flashing to which
bituminous materials are to be adhered shall be primed prior to installation. {11907.G)
8 tur a er
+ I
ature of i o der Date