Checkoff Sheet MS-2014-02451.tif 2009 INTERNATIONAL RESIDENTIAL CODE CITY OF BLA REROOFING CHECKOFF SHEET Return to Blair City ball prior to Final Inspection 218 S `1 Street, Blair, NE 68008 Because of limitations caused by the infeasibility to perform detailed inspections which would not interfere with reroofing work, please indicate compliance with the following requirements following this reroofing job. Property Address Contractor or Homeowner (if self) W 4 Permit #: - 0 / - �q' Installation Date; , YES NO The materials and methods of application used for recovering or replacing the existing roof covering comply with the requirements of the building code. (89037,1) ICE PROTECTION INSTALLED: An ice barrier that consists of at least two layers of underlayment or of a selfWadhering polymer modified bitumen sheet was installed and extends at least from the eave's edge to a point at least 24 inches inside the exterior wall line of the building, (R905.2.7,I) STRUCTURAL COMPONENTS ARE SOUND: The structural roof components are capable of supporting the roof system and the material. and equipment loads that will be encountered during installation of the roof covering system. (8907.2) EXISTING COVERING VITAS REMOVED: Existing roof covering was removed for one of the reasons required bit section 8907.3 DID NOT USE RUSTED ME TAL OR FLASHINGw Existing vent flashing, metal edges, in outlets, collars or metal counter - flashing were not reinstalled if rusted. 18907.5) FLASHING INSTALLED PROPERL Flashing shall be reconstructed in accordance with approved manufacturer's installation instructions, Metal flashing to which bituminous materials are to be adhered shall be primed prior to Installation. (R907.6) Signat many Installer p ignaturo o r older bate I