Checkoff Sheet MS-2014-00758.tif INTERNATIONAL
CODE
IT BL AIR IN CHECKOFF
Return to Blair City Hall prior to Final Inspection
27 8 S i 6 Street, Blair, NB 68008
Because of limitations caused by the infeasibility to'perform detailed inspections which would
not interfere with reroofing work, please indicate compliance with the following
following this reroofing job.
Permit #: _
Installation Date: 1
YES NO
The materials and methods of application used for recovering or replacing the existing
roof covering comply with the requirements of the building code. (R907.1)
ICE PROTECTION
INSTALLED: An ice barrier that consists of at least two layers of
u rid eriayment or of a self- adhering polymer modified bitumen sheet was installed and
extends at least from the eave's edge to a point at least 24 inches inside the exterior
wall line of the building. (R905.2.7.1)
® STRUCTURAL COMPONENTS ARE SOUND: The structural roof components are
capable of supporting the roof covering system and the material and equipment loads
that will be encountered during installation of the roof covering system. (R907.2)
® EXISTING COVER 1 M(; WAS REMOVED: Existing roof covering was removed for one
of the reasons required by section R907.3
NO RUSTED METAL OR PLASHING: Existing vent flashing, metal edges, drain
outlets, collars or metal counter - flashing were not reinstalled if rusted. (R907.5)
in FLASH ING INSTALLED PROPERLY: Plashing shall be reconstructed in accordance
with approved manufacturer's installation instructions. Metal flashing to which
bituminous ateriais are to be adhered shall be primed prior to installation. (R907.6)
w a_
Signature o rimary Installer
Date
Date
Signature of Permit Holder