Return to Blair City Hill prior to, Final Inspection
218 S l8 Str6et, Blair, NE 68008
Because of limitations caused by the•irlfeasibility ter perfdrm detAlled inspections which would
not interfare with reroofing work, please indicate compliance with the following requirements
followinin this reroofing job.
Property Address: t t ji
Contractor or Homeowner (if self)
Permim MS- 2014- r-
Installation Deter' --�-
YES NO
The.materials and methods of, application used: or recovering or, replaclrig,,the existing
roof covering., comply with the .requirements of the building' code:
ICE PROTECTION INSTALLED An ice barrier hat consists of at least two Dyers of
undedayrrrent "or of a self°adhering polymer modified bitumen sheet was installed and
extends at least from the eaves edge to a p6inf a least 24 1 chef inside the exterior
wall "lllne of the building. (R905.2:7.1)
:.. STRUCTURAL CQMPONENt .ARE S0UND: he structural roof components are
capable of supporting the roof covering system a' nd the,material and,equipment loads
that will 6e encountered during installation of the roof'covering system. (11907.2)
EXISTING COVERINg_M AS RELAOMED: Existing roof covering was removed for one
of the reasons required by section 8907.3
DID NOT USE RUSTED METAL, OR FLASHING: L.Xisting vent fleshing, metal edges,
drain outlets, collars or metal counter flashing, w're not..reinstalled if rusted. (8007.5)
® .> FLASHING INSTALL;ED'PROPERLY: Flashing shall be reconstructed in accordance
with approved manufacturer's installation instructions. Mehl flashing to which
bituminous materials are to be adhered shall be ?primed prior to installation. (8907,5)
Signature of Prinfary In taller ; - Data