Checkoff Sheet MS-2014-02389.tif 2009 INTERNATIONAL RESIDENTIAL CODE - I �. . REROO FING i on � Return to Carr City Hall pr to Ft aspect 218. 16 Street, lalr NE 88408 Because of limitations caused I the infeasibility to, *perform detailed Inspe ns w hi ch wo not interfere with reroofing work, please Indicate compliance with the fol o g cd f this reroofing job. Permit #: Installation Date: t�.lr YES NO The materials and methods of application used for recovering or replacing the existing roof covering comply with the requirements of the building code. (11907.1) ICE PROTECTION INSTALLED; An ice barrier that consists of at leas two ta y r and sheet under { - ;mentor of a self - adhering polymer modified bitumen extends at least from the eave's edge to a point at least 24 Inches inside the exterior wall line of the building. (R905.2.7.1) . The structural roof components are STRUCTURAL COMPONENTS ARE SOUND. e and the material and equipment loads capable of supporting the roof covering y that will be encountered during installation of the roof covering system. (8907.2) for one EXISTING C OVERING V1'AS REMOVED: Existing roof covering was r emoved of the reasons required by section R907.3 NO RUSTED METAL OR FLASHING; Existing vent flashing, metal edges, drain outlets, collars or metal counter- flashing were not reinstalled if rusted. (R907.5) i FLASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance with approved manufacturer's installation instructions. Metal flashing to which bituminous aterials are to be adhered shall be primed prior to installation. (R907.6) ° t'Z i zJ i ` Sign e of � unary st r Date °3 2 Sign, re 0 f per it H er