Checkoff Sheet MS-2014-02389.tif 2009 INTERNATIONAL RESIDENTIAL CODE -
I �. . REROO FING i on �
Return to Carr City Hall pr to Ft aspect
218. 16 Street, lalr NE 88408
Because of
limitations caused I the infeasibility to, *perform detailed Inspe ns w hi ch wo
not interfere with reroofing work, please Indicate compliance with the fol o g cd
f this reroofing job.
Permit #:
Installation Date:
t�.lr
YES NO
The materials and methods of application used for recovering or replacing the existing
roof covering comply with the requirements of the building code. (11907.1)
ICE PROTECTION INSTALLED; An ice barrier that consists of at leas two ta y r and sheet
under { - ;mentor of a self - adhering polymer modified bitumen
extends at least from the eave's edge to a point at least 24 Inches inside the exterior
wall line of the building. (R905.2.7.1)
. The structural roof components are
STRUCTURAL COMPONENTS ARE SOUND. e and the material and equipment loads
capable of supporting the roof covering y
that will be encountered during installation of the roof covering system. (8907.2)
for one
EXISTING C OVERING V1'AS REMOVED: Existing roof covering was r emoved
of the reasons required by section R907.3
NO RUSTED METAL OR FLASHING; Existing vent flashing, metal edges, drain
outlets, collars or metal counter- flashing were not reinstalled if rusted. (R907.5)
i
FLASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance
with approved manufacturer's installation instructions. Metal flashing to which
bituminous aterials are to be adhered shall be primed prior to installation. (R907.6)
° t'Z i zJ i `
Sign e of � unary st r
Date
°3 2
Sign, re 0 f per it H er