Loading...
Checkoff Sheet MS-2014-00440_0001.tif 2009 INTERNATIONAL RESIDENTIAL CODE CITY OF BLAIR REROOFING CHEC KOFF SHEET Return to Blair city Hall prior to Final Inspection j 218 S 16 street, Blair, NE 68008 Because of limitations caused by the infeasibility to'perform detailed inspections which would not interfere with reroofing work, please indicate compliance with the following requirements following this reroofing job. Permit #: 0l 00 Installation Date: YES NO Q The materials and methods of application used for recovering or replacing the existing roof covering comply with the requirements of the building code. (R907.1) Q ICE PROTECTION INSTALLED: An ice barrier that consists of at least two layers of underlayment or of a self- adhering polymer modified bitumen sheet was installed and extends at least from the eaye's edge to a point at least 24 inches inside the exterior wall line of the building. (R905.2.7.1) ,[ [� STRUCTURAL COMPONENTS ARE SOUND: The structural roof components are capable of supporting the roof covering system and the material and equipment loads that will be encountered during installation of the roof covering system. (8907.2) ® EXISTING COVERING WAS REMOVED: Existing roof covering was removed for one of the reasons required by section 8907.3 Q NO RUSTED METAL OR Existing vent flashing, metal edges, drain FLASHING: outlets, collars or metal counter - flashing were not reinstalled if rusted. (R907.5) Q FLASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance with approved manufacturer's installation instructions. Metal flashing to which bituminous materials are to be adhered shall be primed prior to installation. (R907.6) d � � e"f igna ure of Primary Installer Date j I Signature of Permit Holder Date