883 (2).tif i 07- 23 -'14 15;19 FAO]- Absolute Customs T -038 P0004/0004 F -074 2009 INTERNATIONAL RES CO CITY OF AID. REROOFING E KOFF SHEET Return to wair c i ty Hall prier t o Final Inspection 2 1 8S 1 6 th S treet, Blair, NE 68008 1390ause of limitations caused by the Infeasibility to'perform detadled Inspections which would Mot interFere with reroofing work please Indicate comp lance with t'he following requirements allowing this reroofing job. installati Date: ,/ J ' V YES NO The material$ and methods of appllcaticn used for recovering or replacing the existing roof covering comply with the requirements of the building code, (11907.1) ICE PROTECTION IN ALLEA: An ice barrier that consists of of least two layers of underlayment or of a self - adhering polymer modified bitumen sheet was stalled and extends t least from the eave's edge to a point at l� 4 Inc es inside the exterior wall lime of the building. (R905,2.7.1) STRUCTURAL cpMPONENTS ARV, SOUND: The structural roof c rnponents a capable of supporting the roof covering system and the material and equipment l oads that will be encountered during Installation of the roof covering system. (11907.2) }tISTIN C� ' 14G WAS REMOVED: Existing roof covering was removed for one of the reasons required by section 8907.3 C3 f40 RUS"TEt� METAL OR pL.A I - 1 NFL Existing vent flashing, metal edges, drain outlets, collars or Metal counter were not reinstalled if rusted, (8907 +6) C3 F4A514ING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance with approved manufacturer's installation instructions. Metal flashing to which bituminous materials are to be adhered shall be primed prier to installation. (R907.6) signature of Primary installer ate Q q 11 In — .4 1gnature of rmit Ho der ' c i t