CITY O RE ROOFING CHECKOFF SHEET F
Return to Blair City Hallpriorto Final inspection ,
th Blair NB 68008
2� 8 S � 6 Street,
Because of limitations caused b the infeasibility to 'perform detailed inspections which would
not interfere with reroofing work, please indicate compliance with the following requirements
following this reroofing job.
Permit #:
Installation Date:
YES NO
materials and methods of application used for recovering or replacing the existing
The mat e
� rt
roof covering comply with the requirements of the building code. (R907.1)
L� ICE PROTECTI
ON INSTALLED: An ice barrier that consists of at least two layers of
underlayment or of a self - adhering polymer modified bitumen sheet was installed and
ext at least from the eave's ed e to a point at least 24 inches inside the exterior
wail line of the building. (R905.2.7.1)
STRUCTURAL. COMPONENTS ARE SOUND: The structural roof components are
y
capable of supporting the roof covering system and the material and equipment loads
that will be encountered during installation of the roof covering system. (R907.2)
1 =XlSTI NG COVERING WA REMOVED: Existing roof'covering was removed for one
� ,
of the reasons required by section R907.3
NO RUSTED METAL OR FLASHING: Existing vent flashing, metal edges, drain
outlets, collars or metal counter - flashing were not reinstalled if rusted. (R907.6)
ASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance
with approved manufacturer's installation instructions. Metal flashing to which
bituminous materials are to be adhered shall be primed prior to installation. (R907.6)
,
i
Signature of Primary Installer Date