Loading...
1425_0001.tif 2009 INTERNATIONAL RESIDENTIAL CODE i CITY OF BLAIR REROOFING Return to Blair City Hall prior to Final Inspection 218S16 th Street, Blair, NE 68008 Because of limitations caused by the infeasibility to perform detailed inspections which would not Interfere with reroofing work, please indicate compliance with the following requirements foil wing this reroofing job. Permit #: Installation Date: e f YES NO The materials and methods of application used for recovering or replacing the existing roof covering comply with the requirements of the building code. (R907.1) ICE PROTECTION INSTALLED; An ice barrier that consists of at least two layers of self- adhering polymer modified bitumen sheet was installed and underlayment or of a extends at least from the eavg' edge to a point at least 24 inches inside the exterior wall line of the building. (R905.2.7.1) STRUCTURAL COMPONENTS ARE SOUND: The structural roof components are of capable supporting the roof covering system and the material and equipment loads p pp g that will be encountered during installation of the roof covering system. (8907.2) EXISTING COVERING WAS REMOVED: Existing roof covering was removed for one of the reasons required by section R907.3 NO RUSTED METAL OR FLASHING: Existing vent flashing, metal edges, drain outlets, collars or metal counter - flashing were not reinstalled if rusted. (R907.5) ❑ FLASHING INSTALLED PROPERLY: Flashing shall be reconstructed in accordance with approved manufacturer's installation instructions. Metal flashing to which bituminous materials are to be adhered shall be primed prior to insta ation. (8907.6) Signature of Primary Installer Date Si ature of Permit Ho der Date SEEM i y i