3100 Adams St-1.tif dip FDH Engineering, Inc. 222 S. Central Avenue Suite 1110 St. Louis, MO 63105 314 - 773 -4000 Thursday, March 06, 2014 i RIGOROUS STRUCTURAL ANALYSIS 60' Monopole I AT &T DESIGNATION: Site ID: 114877 -A Site FA: 10084514 Site Name: Blair Project Number: 1422012400 Carrier Project: MOD LTE 1.16.14 ANALYSIS CRITERIA: ANSI/TIA -222 -G Codes: I SITE DATA: 3100 Adams Street, Blair, NE 68008, Washington County Latitude 41.55132, Longitude - 96.16041 Market: ND /SD /NE /MN /IA 60' Monopole Pat Conlin, FDH Engineering Inc. is pleased to submit this Structural Analysis Report to determine the structural integrity of the aformentioned tower. The purpose of the analysis is to determine the suitability of the tower with the existing and proposed loading configuration detailed in the analysis report. I Analysis Results Tower Stress Level with Proposed Equipment: 96.90% Pass Foundation Ratio with Proposed Equipment: 66.50% Pass f I i i We at FDH Engineering Inc. appreciate the opportunity of providing our continuing professional services to you and AT &T Towers. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully Submitted by: Michael Brennan, El NL Q DENNIS 0. Analysis Prepared by: Michael Brennan, El a ABEL E -11907 Analysis Reviewed by: Dennis D. Abel, PE's OF�N p -T-dbZat `l AT &T Proprietary (Internal Use Only) Not for use or disclosure outside the AT &T companies except under written agreement I I i i FDH Engineering, Inc., 222 S. Central Avenue, Suite 1110 St. Louis, MO 63105, Ph. 314.773.4000, Fax 314.773.4002 Rigorous Structural Analysis for FMHC Corporation 60' Monopole Tower I AT &T Site Name: Blair AT &T Site ID: 114877 -A Carrier Project: MOD LTE 1.16.14 FA Number: 10084514 FDH Project Number 1422012400 Analysis Results Tower Components 96.9% Sufficient Foundation 66.5% Sufficient i Prepared By: Reviewed By: kLi Aq Michael Brennan, El Dennis D. Abel, PE Project Engineer Director of Structural Engineering NE PE License No. E -11907 FDH Engineering, Inc. L J 222 S. Central Avenue, Suite 1110 II St. Louis, MO 63105 neNertls (314) 773 -4000 ABEL E-1 1907 info @fdh- inc.com OF ld March 6, 2014 0 9 -06 Prepared pursuant to ANSIITIA -222 -G Structural Standard for Antenna Supporting Structures and Antennas Document No. ENG- RPT -501S ffi _ Revision Date: 06/17111 i Structural Analysis Report FMHC Corporation AT &T Site I D:114877 -A March 6, 2014 TABLE OF CONTENTS EXECUTIVESUMMARY ............................................. ........... .............................. .............. ........................................................ 3 Conclusions.............................................................................................................................................. ..............................3 Recommendations................................................................................................................................... ..............................3 APPURTENANCELISTING ......................................................................................................................... ..............................4 RESULTS .................................................................................................................................................... ............................... 5 i GENERAL COMMENTS LIMITATIONS............................................................................................................................................... ..............................6 APPENDIX ................................................................................................................................................... ..............................7 I I I I i I i i i Document No. ENG- RPT -501S Revision Date: 06/17/11 j 2 I Structural Analysis Report FMHC Corporation AT &T Site ID: 114877 -A March 6, 2014 EXECUTIVE SUMMARY At the request of FMHC Corporation, FDH Engineering, Inc. performed a structural analysis of the monopole located in Blair, NE to determine whether the tower is structurally adequate to support both the existing and proposed loads pursuant to the Structural Standard for Antenna Supporting Structures and Antennas, ANSI/TIA- 222 -G. Information pertaining to the existing /proposed antenna loading, current tower geometry, geotechnical data, foundation dimensions, and member sizes was obtained from: I ❑ Valmont (Order No. 143432) original design drawings dated March 1, 2011 ❑ ISG & Associates, Inc. (Project No. 10174) Geotechnical Engineering Report dated December 6, 2010 ❑ All documents and photos from AT &T's Siterra ❑ FMHC Corporation The basic design wind speed per the ANSIITIA -222 -G standard is 90 mph without ice and 50 mph with 3/4" radial ice. Ice is considered to increase in thickness with height. Furthermore, this structure as analyzed as a Class II structure in Exposure Category C with a topographical factor 1 and Spectral Response Accelerations of Ss =0.119 and S1= 0.040. Note: Per Section 2.7.3 of the ANSI /TIA -222 -G standard, the seismic /earthquake loading effects can be ignored if spectral response acceleration at short periods (Ss) is less than or equal to 1.00. The tower's location mandates a design Ss of less than 1.00, thus seismic loading was not considered as part of the analysis of this structure. i Conclusions With the existing and proposed antennas from AT &T in place at 50 ft, the tower meets the requirements of the ANSI1TIA -222- G standard provided the Recommendations listed below are satisfied. Furthermore, provided the foundation was constructed per the original design drawings (see Valmont Order No. 143432) and utilizing the existing soil parameters (see ISG Project No. 10174) the foundation should have the necessary capacity to support the existing and proposed loading. For a more detailed description of the analysis of the tower, see the Results section of this report. Our structural analysis has been performed assuming all information provided to FDH Engineering, Inc. is accurate (i.e., the steel data, tower layout, existing antenna loading, and proposed antenna loading) and that the tower has been properly erected and maintained per the original design drawings. Recommendations To ensure the requirements of the ANSI /TIA -222 -G standard are met with the existing and proposed loading in place, we have the following recommendations: i 1. Feedlines must be installed inside the pole's shaft. 2. RRH /RRU Stipulation: The equipment may be installed in any arrangement as determined by the client. i I I Document No. ENG- RPT -501S Revision Date: 06/17/11 3 I i i i Structural Analysis Report FMHC Corporation AT &T Site ID: 114877 -A March 6, 2014 APPURTENANCE LISTING The proposed and existing antennas with their corresponding cables /coax lines are shown in Table 1. If the actual layout determined in the field deviates from the layout, FDH Engineering, Inc, should be contacted to perform a revised analysis, j Table 1 - Appurtenance Loading Existing Loading: Descri Antenna Mount Elevation I 50 (6) Kathrein 80010765 w/ Mount Pipe 6 Powerwave TT19- 08BP111 -001 TMAs (12)1 518" AT &T 50 (1) Platform w/ Handrails 1. Feedlines located inside the pole's shaft unless otherwise noted. I Proposed Loading: Descri Antenna Mount Elevation •. lines Carrier Elevation Mount .- Azimutho (6) Andrew SBNHH -1 D65B w/ Mount Pipe (3) ALU RRH2x40 -07 -L RRHs (1) Platform 50� (3) ALU RRH2X40- 07L -DE RRHs (4) 0.773 DC AT &T 50 w / Handrails 1,110,220 j (3) ALU RRH2X40 -AWS RRHs (1) 0.4" Fiber (existing) (3) ALU RRH4x25 -WCS RRHs 2 Ra cap DC6- 48- 60 -18 -8F Fiber Box 1. Proposed loading is in addition to the existing loading at 50'. I j j ( I i Document No. ENG- RPT -501S Revision Date: 06/17/11 I 4 j Structural Analysis Report FMHC Corporation AT &T Site ID: 114877 -A March 6, 2014 RESULTS The following yield strength of steel for individual members was used for analysis: Table 2 - Material Strength Yiel Member Type Strength Tower Shaft Sections 65 ksi Base Plate 50 ksi Anchor Bolts 75 ksi i Table 3 displays the summary of the ratio (as a percentage) of force in the member to their capacities. Values greater than 100% indicate locations where the maximum force in the member exceeds its capacity. Note: Capacities up to 105% are considered acceptable. Table 4 displays the maximum foundation reactions. If the assumptions outlined in this report differ from actual field conditions, FDH Engineering, Inc. should be contacted to perform a revised analysis. Furthermore, as no information pertaining to the allowable twist and sway requirements for the existing or proposed appurtenances was provided, deflection and rotation were not taken into consideration when performing this analysis. See the Appendix for detailed modeling information Table 3 - Summary of Working Percentage of Structural Components Section Elevation C N ft Type Fail L1 60-36.67 Pole TP15.425x12.2754.188 1 32.9 Pass L2 36.67-0 Pole 720x14.60.188 96.9 1 Pass Anchor Bolts 4 2.25 "G wl a 26.81" B.C. 60.0 Pass Base Plate I PL 32.51'0: 2" Thk. 64.7 Pass Table 4 - Maximum Base Reactions Current Analysis* Base • • Reacti , �, Axial 7 k 6 k Shear 7 k 4 k Moment 337 k-ft 181 k -ft 'Foundation determined adequate per independent analysis. I Document No. ENG- RPT -501S Revision Date: 06/17/11 5 i Structural Analysis Report FMHC Corporation AT &T Site ID: 114877 -A March 6, 2014 GENERAL COMMENTS This engineering analysis is based upon the theoretical capacity of the structure. It is not a condition assessment of the tower and its foundation. It is the responsibility of FMHC Corporation to verify that the tower modeled and analyzed is the correct structure (with accurate antenna loading information) modeled. If there are substantial modifications to be made or the assumptions made in this analysis are not accurate, FDH Engineering, Inc. should be notified immediately to perform a revised analysis. LIMITATIONS All opinions and conclusions are considered accurate to a reasonable degree of engineering certainty based upon the evidence available at the time of this report. All opinions and conclusions are subject to revision based upon receipt of new or additional /updated information. All services are provided exercising a level of care and diligence equivalent to the standard and care of our profession. No other warranty or guarantee, expressed or implied, is offered. Our services are confidential in nature and we will not release this report to any other party without the client's consent. The use of this engineering work is limited to the express purpose for which it was commissioned and it may not be reused, copied, or distributed for any other purpose without the written consent of FDH Engineering, Inc. I i I i I I I I I I i Document No. ENG- RPT -501S Revision Date: 06/17/11 6 I I i DESIGNED APPURTENANCE LOADING 60.0 ft TYPE ELEVATION TYPE ELEVATION Lightning Rod 60 RRH2x40 -07 -L 50 (1) Platform w/ Handrails 50 RRH2X40- 07L -DE 50 ! (2) 800 10765 w/ Mount Pipe 50 RRH2X40- 07L -DE 50 (2) 800 10765 w/ Mount Pipe 50 RR112X40- 071--DE 50 (2) 800 10765 w/ Mount Pipe 50 RRH2X40 -AWS 50 j (2)7719- 08BP111 -001 TMA 50 RRH2X40 -AWS 50 (2)TT19- 08SP111 -001 TMA 50 RRH2X40 -AWS 50 (2) TT10.08BP111 -001 TMA 50 RRH4x25 -WCS RRH 50 (2) SBNHH -1D65B w/ Mount Pipe 50 RRH4x25 -WCS RRH 50 (2) SBNHH -1D65B w/ Mount Pipe 50 RRH4x25•WCS RRH 50 (2) SBNHH -1D65B w/ Mount Pipe 50 DC6-48-60 -18-8F 50 RRH2x40.07 -L 5o DC6- 48- 60 -18-8F 50 " I in ".:= ." RRH2x40.07 -L 50 M r N ro c6 W M N C N �2 �2 MATERIAL STRENGTH GRADE Fy Fu GRADE I Fy Fu A572 -65 165 ksi 180 ksi TOWER DESIGN NOTES 1. Tower is located in Washington County, Nebraska. 2. Tower designed for Exposure C to the TIA -222 -G Standard. 3. Tower designed for a 90 mph basic wind in accordance with the TIA -222 -G Standard. 4. Tower is also designed for a 50 mph basic wind with 0.75 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 36.7 ft 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING: 96.9% 6 a I i i i S I I ALL REACTIONS ARE FACTORED I AXIAL 15K SHEAR MOMENT 3K 164 kip -ft i TORQUE 0 kip -ft 50 mph WIND - 0.750 in ICE AXIAL 7K SHEAR MOMENT 7 K 337 kip -ft N 0.0 a TORQUE 1 kip -ft REACTIONS - 90 mph WIND - m _ o E m p N y E m � z' t✓ m r m c0 3 I FDHEiigineering, Inc. l ob: Blair - NE (114877 -A) 6521 Meridien Drive, Suite 107 Pro)ect 1422012400 Raleigh, North Carolina C1ient FMHC Corporatio Drawn by:MBrenna App'd: Tower Analysis Phone: 9197551012 Code: TIA -222 -G Date :03 /06/14 Scale: NTS FAX: 9197551031 Path ciu rs m e w �sxm am t a o m a�i. NE 4w al8lair NE.eA Dwg No ' E -1 i I I Job Page tYlxToWer Blair - NE (114877 -A) 1 of 11 i i FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:5103/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX: 9197551031 Tower Input Data i There is a pole section. This tower is designed using the TIA -222 -G standard. The following design criteria apply: Tower is located in Washington County, Nebraska. Basic wind speed of 90 mph. Structure Class IL Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 0.750 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 50 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. A non - linear (P- delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X -Brace Ly Rules Consider Moments - Diagonals 4 Assume Rigid Index Plate q Calculate Redundant Bracing Forces Use Moment Magnification J Use Clear Spans For Wind Area Ignore Redundant Members in FEA Use Code Stress Ratios 4 Use Clear Spans For KL /r SR Leg Bolts Resist Compression 4 Use Code Safety Factors - Guys 4 Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice 4 Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz Use Azimuth Dish Coefficients Consider Feedline Torque Use Special Wind Profile 4 Project Wind Area of Appurt. Include Angle Block Shear Check 4 Include Bolts In Member Capacity Autocalc Torque Arni Areas Poles 4 Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear - Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub - Critical Flow Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC .6D +W Combination Use TIA -222 -G Tension Splice Capacity Exemption I I Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 60.00 -36.67 23.33 3.33 18 12.275 15.425 0.188 0.750 A572 -65 (65 ksi) L2 36.67 -0.00 40.00 18 14.600 20.000 0.188 0.750 A572 -65 (65 ksi) I I i i i I Job Page ( tnz�'Ower Blair - NE (114877 -A) 2 of 11 FDHEngizzeering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:51 O3/O6/14 Raleigh, North Carolina Client Designed by Phone: 9197.551012 FMHC Corporation MBrennan FAX.- 9197551031 I Tapered Pole Properties i Section Tip Dia. Area I r C I/C J It /Q w w/t in in in in in in in in in L1 12.464 7.194 132.787 4.291 6.236 21.295 265.748 3.597 1.830 9.762 15.663 9.068 266.003 5.409 7.836 33.947 532.356 4.535 2.385 12.719 L2 15.282 8.577 225.112 5.117 7.417 30.351 450.520 4.290 2.240 11.945 20.309 11.791 584.741 7.033 10.160 57.553 1170.251 5.897 3.190 17.013 Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. WeightMult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt (perface) A Spacing Spacing Diagonals Horizontals ft fr in in in Ll 60.00 -36.67 1 1 1 L2 36.67 -0.00 1 1 1 I i Feed Line /Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAA Weight or Shield Type Number Leg ft ft pf 1 -5/8" C No Inside Pole 50.00-0.00 12 No Iee 0.00 1.04 1/2" Ice 0.00 1.04 P Ice 0.00 1.04 0.773 DC C No Inside Pole 50.00-0.00 4 No Ice 0.00 0.47 1/2" Ice 0.00 0.47 I" Ice 0.00 0.47 0.4" Fiber C No Inside Pole 50.00-0.00 1 No Ice 0.00 0.25 1/2" Ice 0.00 0.25 P Ice 0.00 0.25 Safety Line 3/8 C No CaAa (Out Of 60.00-0.00 1 No Ice 0.04 0.22 Face) 1/2" Iee 0.14 0.75 1" Ice 0.24 1.28 I Feed Line /Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Section Elevation In Face Out Face ft ft ft ft ft K LI 60.00 -36.67 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.875 0.20 L2 36.67 -0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 1.375 0.54 Feed Line /Linear Appurtenances Section Areas - With Ice i i i Job Page tnx-Tower Blair - NE (114877 -A) 3 of 11 FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32 :51 03/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX. 9197551031 Tower Tower Face Ice A A C A A A C A A A Weight Section Elevation or Thickness In Face Out Face ft Leg in fi? fl ft f? K L1 60.00 -36.67 A 1.557 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 8.139 0.24 L2 36.67 -0.00 A 1.412 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 12.794 0.60 Feed Line Center of Pressure Section Elevation CPX CP CPX CPz Ice Ice ft in in in in L1 60.00 -36.67 -0.046 0.027 -0.294 0.170 L2 36.67 -0.00 -0.047 0.027 -0.316 0.183 Shielding Factor Ka Tower Feed Line Description Feed Line K. K. Section Record No. Segment Elev. No Ice Ice Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft f? f? K ft ft Lightning Rod C From Leg 0.00 0.0000 60.00 No Ice 0.25 0.25 0.03 0.00 1/2" Ice 0.66 0.66 0.03 2.00 1" Ice 0.97 0.97 0.04 (1) Platform w/ Handrails C None 0.0000 50.00 No Ice 30.10 30.10 1.59 1/2" Ice 40.80 40.80 2.03 1" Ice 51.50 51.50 2.47 (2) 800 10765 w/ Mount Pipe A From Leg 4.00 0.0000 50.00 No Ice 8.90 6.72 0.08 0.00 1/2" Ice 9.57 7.95 0.15 0.00 1" Ice 10.22 8.92 0.22 (2) 800 10765 w/ Mount Pipe B From Leg 4.00 0.0000 50.00 No Ice 8.90 6.72 0.08 0.00 1/2" Ice 9.57 7.95 0.15 0.00 V Ice 10.22 8.92 0.22 (2) 800 10765 w/ Mount Pipe C From Leg 4.00 0.0000 50.00 No Ice 8.90 6.72 0.08 0.00 1/2" Ice 9.57 7.95 0.15 0.00 P Ice 10.22 8.92 0.22 (2) TT19- 08BP111 -001 TMA A From Leg 4.00 0.0000 50.00 No Ice 0.64 0.52 0.02 0.00 1/2" Ice 0.76 0.62 0.02 l i Job Page tnzTo_,wer Blair - NE (114877 -A) 4 of 11 I FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:51 03/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX- 9197551031 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft o ft fig fry K ft ft 0.00 1" Ice 0.88 0.74 0.03 (2) TT19- 08BP111 -001 TMA B From Leg 4.00 0.0000 50.00 No Ice 0.64 0.52 0.02 0.00 1/2" Ice 0.76 0.62 0.02 0.00 V Ice 0.88 0.74 0.03 (2) TT19- 08BP111 -001 TMA C From Leg 4.00 0.0000 50.00 No Ice 0.64 0.52 0.02 0.00 1/2" Ice 0.76 0.62 0.02 0.00 1" Ice 0.88 0.74 0.03 (2) SBNHH -1D65B w/ A From Leg 4.00 0.0000 50.00 No Ice 8.86 7.30 0.07 Mount Pipe 0.00 1 /2" Ice 9.62 8.58 0.14 0.00 1" Ice 10.34 9.72 0.22 (2) SBNHH -1D65B w/ B From Leg 4.00 0.0000 50.00 No Ice 8.86 7.30 0.07 Mount Pipe 0.00 1 /2" Ice 9.62 8.58 0.14 0.00 V Ice 10.34 9.72 0.22 (2) SBNHH -1D65B w/ C From Leg 4.00 0.0000 50.00 No Ice 8.86 7.30 0.07 Mount Pipe 0.00 1/2" Ice 9.62 8.58 0.14 0.00 V Ice 10.34 9.72 0.22 RRH2x40 -07 -L A From Leg 4.00 0.0000 50.00 No Ice 1.99 1.82 0.05 0.00 1/2" Ice 2.19 2.01 0.07 0.00 1" Ice 2.40 2.21 0.09 RRH2x40 -07 -L B From Leg 4.00 0.0000 50.00 No Ice 1.99 1.82 0.05 0.00 1/2" Ice 2.19 2.01 0.07 0.00 P Ice 140 2.21 0.09 RRH2x40 -07 -L C From Leg 4.00 0.0000 50.00 No Ice 1.99 1.82 0.05 0.00 1/2" Ice 2.19 2.01 0.07 0.00 1" Ice 2.40 2.21 0.09 RRH2X40- 07L -DE A From Leg 4.00 0.0000 50.00 No Ice 2.99 1.49 0.05 0.00 1/2" Ice 3.24 1.70 0.07 0.00 1" Ice 3.49 1.92 0.09 RRH2X40- 07L -DE B From Leg 4.00 0.0000 50.00 No Ice 2.99 1.49 0.05 0.00 1 /2" Ice 3.24 1.70 0.07 0.00 1" Ice 3.49 1.92 0.09 RRH2X40- 07L -DE C From Leg 4.00 0.0000 50.00 No Ice 2.99 1.49 0.05 0.00 1/2" Ice 3.24 1.70 0.07 0.00 1" Ice 3.49 1.92 0.09 RRH2X40 -AWS A From Leg 4.00 0.0000 50.00 No Ice 2.52 1.59 0.04 0.00 1/2" Ice 2.75 1.80 0.06 0.00 1" Ice 2.99 2.01 0.08 RRH2X40 -AWS B From Leg 4.00 0.0000 50.00 No Ice 2.52 1.59 0.04 j 0.00 1/2" Ice 2.75 1.80 0.06 0.00 1" Ice 2.99 2.01 0.08 RRH2X40 -AWS C From Leg 4.00 0.0000 50.00 No Ice 2.52 1.59 0.04 0.00 1/2" Ice 2.75 1.80 0.06 0.00 V Ice 2.99 2.01 0.08 RRH4x25 -WCS RRH A From Leg 4.00 0.0000 50.00 No Ice 4.45 3.81 0.09 0.00 VT Ice 4.77 4.11 0.13 0.00 1" Ice 5.09 4.43 0.16 RRH4x25 -WCS RRH B From Leg 4.00 0.0000 50.00 No Ice 4.45 3.81 0.09 0.00 1/2" Ice 4.77 4.11 0.13 0.00 V Ice 5.09 4.43 0.16 RRH4x25 -WCS RRH C From Leg 4.00 0.0000 50.00 No Ice 4.45 3.81 0.09 0.00 1/2" Ice 4.77 4.11 0.13 0.00 1" Ice 5.09 4.43 0.16 DC6- 48- 60 -18 -8F A From Leg 4.00 0.0000 50.00 No Ice 2.57 4.32 0.02 0.00 1/2" Ice 2.80 4.60 0.05 0.00 1" Ice 3.04 4.88 0.09 DC6- 48- 60 -18 -8F B From Leg 4.00 0.0000 50.00 No Ice 2.57 4.32 0.02 0.00 1/2" Ice 2.80 4.60 0.05 i Job Page tn xTower Blair - NE (114877 -A) 5 of 11 FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:5103/06/14 I Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.- 9197551031 Description Face Offset Offs ets: Azimuth Placement C CAAA Weight or Type Harz Adjustment Front Side Leg Lateral Vert ft o ft ft� frz K ft ft 0.00 1" Iee 3.04 4.88 0.09 i i I Tower Pressures - No Ice G =1.100 Section z Kz qz AG F AF AR Al Leg CAAA CAAA Elevation a % In Out c Face Face t ft Psf fr e f? .f� fi� f? f? L160.00 -36.67 47.89 1.084 21 27.342 A 0.000 27.342 27.342 100.00 0.000 0.000 B 0.000 27.342 100.00 0.000 0.000 C 0.000 27.342 100.00 0.000 0.875 L2 36.67 -0.00 18.04 0.883 18 54.379 A 0.000 54.379 54.379 100.00 0.000 0.000 B 0.000 54.379 100.00 0.000 0.000 C 1 0,0001 54.379 1 1 100.00 1 0.000 1.375 I Tower Pressure - With Ice GH =1.100 Section z K q tz A F A A At, Leg CAAA C Elevation a % In Out c Face Face ft ft sf in ft� e ft� f? ft� ft� ft� L160.00 -36.67 47.89 1.084 7 1.557 33.396 A 0.000 33.396 33.396 100.00 0.000 0.000 B 0.000 33.396 100.00 0.000 0.000 C 0.000 33.396 100.00 0.000 8.139 L2 36.67 -0.00 18.04 0.883 5 1.412 63.895 A 0.000 63.895 63.895 100.00 0.000 0.000 B 0.000 63.895 100.00 0.000 0.000 C 0.000 63.895 100.00 0.000 12.794 I Tower Pressure - Service j G 1.loo Section z Kz q AG F AF A A,,, Leg CAAA CAAA i Elevation a % In Out c Face Face .ft ft Psf f? e f? .f� f? f� f? L160.00 -36.67 47.89 1.084 8 27.342 A 0.000 27.342 27.342 100.00 0.000 0.000 B 0.000 27.342 100.00 0.000 0.000 i Job Page tnx. - T wer Blair - NE (114877 -A) 6 of 11 FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:51 03/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation FAX.- 9197551031 p MBrennan i i Section z KZ q Ao F A AR A,,, Leg CAAA CAAA Elevation a % In Out c Face Face ft ft sf ft� e k ft� ? .f? C 0.000 27.342 100.00 0.000 0.875 L2 36.67 -0.00 18.04 0.883 7 54.379 A 0.000 54.379 54.379 100.00 0.000 0.000 B 0.000 54.379 100.00 0.000 0.000 C 0.000 54.379 100.00 0.000 1.375 Tower Forces - No Ice Wind Normal To Face Section Add Self F e C q= D D A F w Ctrl. Elevation Weight Weight a Face c Psf ft K K e f? K Plf L1 0.20 0.65 A 1 0.65 21 1 1 27.342 0.44 18.77 C 60.00 -36.67 B 1 0.65 1 1 27.342 C 1 0.65 1 1 27.342 L2 36.67 -0.00 0.54 1.39 A 1 0.65 18 1 1 54.379 0.72 19.58 C B 1 0.65 1 1 54.379 C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 33.93 1.16 ki -tI Tower Forces - No Ice - Wind 60 To Face Section Add Self F e C q: D D A F w Ctrl. Elevation Weight Weight a Face c Psf ft K K e ft K Plf Ll 0.20 0.65 A 1 0.65 21 1 1 27.342 0.44 18.77 C 60.00 -36.67 B 1 0.65 1 1 27.342 j C 1 0.65 1 1 27.342 L2 36.67 -0.00 0.54 1.39 A 1 0.65 18 1 1 54.379 0.72 19.58 C B 1 0.65 1 1 54.379 C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 33.93 1.16 kip-ft i Tower Forces - No Ice - Wind 90 To Face j Section Add Self F e CF qz DF D A F w CO. Elevation Weight Weight a Face c Psf f} K K e ft� K Pf L1 0.20 0.65 A 1 0.65 21 1 1 27.342 0.44 18.77 C 60.00 -36.67 B 1 0.65 1 1 27.342 C 1 0.65 1 1 27.342 L2 36.67 -0.00 0.54 1.39 A 1 0.65 18 1 1 54.379 0.72 19.58 C B 1 0.65 1 1 54.379 I i I L Job Page tnx -Tower Blair - NE (114877 -A) 7 of 11 Project Date FDHEngineering, Inc. 1422012400 14:32:51 03/06/14 6521 Meridien Drive, State 107 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.- 9197551031 i I Section Add Self F e C q: D D A F w Ctrl. Elevation Weight Weight a Face c psf ft K K e ft K PIf C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 3193 1.16 kip-ft I Tower Forces - With Ice - Wind Normal To Face i Section Add Self F e C q= D D A F w Ctrl. Elevation Weight Weight a Face c psf ft K K e K Pf Ll 0.24 1.34 A 1 1.2 7 1 1 33.396 0.35 14.98 C 60.00 -36.67 B 1 1.2 1 1 33.396 C 1 1.2 1 1 33.396 L2 36.67 -0.00 0.60 2.60 A 1 1.2 5 1 1 63.895 0.54 1432 C B 1 1.2 I 1 63.895 C 1 1.2 1 1 63.895 Sum Weight: 0.84 3.93 OTM 26.48 0.89 kip -ft i i Tower Forces - With Ice - Wind 60 To Face Section Add Self F e C 9= Dr• D A F w Ctrl. Elevation Weight Weight a Face c psf t K K e ft K PV L1 0.24 134 A 1 1.2 7 1 1 33.396 0.35 14.98 C 60.00 -36.67 B 1 1.2 1 1 33.396 C 1 1.2 1 1 33.396 L2 36.67 -0.00 0.60 2.60 A 1 1.2 5 1 1 63.895 0.54 14.72 C B 1 1.2 1 1 63.895 C 1 1.2 1 1 63.895 Sum Weight: 0.84 3.93 OTM 26.48 0.89 kip -ft I I Tower Forces - With Ice - Wind 90 To Face Section Add Self F e CF q. DF DR AE F w Ctrl. Elevation Weight Weight a Face c psf ft K K e ? K Ph' L1 0.24 1.34 A 1 1.2 7 1 1 33.396 0.35 14.98 C 60.00 -36.67 B 1 1.2 1 1 33.396 C 1 1.2 1 1 33.396 L2 36.67 -0.00 0.60 2.60 A 1 1.2 5 1 1 63.895 0.54 14.72 C I Job Page t -Tower Blair - NE (114877 -A) 8 of 11 FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:51 03/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.- 9197551031 j Section Add Self F e CF q� D D AE F w Ctrl. Elevation Weight Weight a Face c psf ft K K e ft� K Plf B 1 1.2 1 1 63.895 C 1 1.2 1 1 63.895 Sum Weight: 0.84 3.93 OTM 26.48 0.89 kip-ft I I Tower Forces - Service - Wind Normal To Face Section Add Self F e CF q= DF D AE F w Face Elevation Weight Weight a c psf ft K K e ft K Plf L1 0.20 0.65 A 1 0.65 8 1 1 27.342 0.17 7.47 C 60.00 -3667 B 1 0.65 1 1 27.342 C 1 0.65 1 1 27.342 L2 36.67 -0.00 0.54 1.39 A 1 0.65 7 1 1 54.379 0.29 7.79 C B 1 0.65 1 1 54.379 C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 13.49 0.46 kip-ft Tower Forces - Service -Wind 60 To Face Section Add Self F e C q, D D A F w Orl. Elevation Weight Weight a Face c psf ft K K e K Plf Ll 0.20 0.65 A 1 0.65 8 1 1 27.342 0.17 7.47 C 60.00 -36.67 B 1 0.65 1 1 27.342 C 1 0.65 1 1 27.342 L2 36.67 -0.00 0.54 1.39 A 1 0.65 7 1 1 54.379 0.29 7.79 C B 1 0.65 1 1 54.379 C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 13.49 0.46 kip-ft I Tower Forces - Service - Wind 90 To Face Section Add Self F e C q= DF DR A F w Ctrl. Elevation Weight Weight a Face c psf ft K K e K Pf Ll 0.20 0.65 A 1 0.65 8 1 1 27.342 0.17 7.47 C 60.00 -36.67 B 1 0.65 1 1 27.342 C 1 0.65 1 1 27.342 i i l Job Page tnxTower Blair - NE (114877 -A) 9 of 11 Project Date FDHEngineering, Ine. 1422012400 14:32:51 03/06/14 6521 Meridien Drive, Suite 107 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.- 9197551031 Section Add Self F e C q= D D A F w Ctrl. Elevation Weight Weight a Face c psf ft K K e f K Plf L2 36.67 -0.00 0.54 1.39 A 1 0.65 7 1 1 54.379 0.29 7.79 C B 1 0.65 1 1 54.379 C 1 0.65 1 1 54.379 Sum Weight: 0.74 2.03 OTM 13.49 0.46 kip -ft Force Totals i Load Vertical Sam¢ of Seim of Sum of Sum of Sum of Torques Case Forces Forces Forces Overturning Overturning X Z Moments, M Moments, M K K K kip-ft kip -ft kip,ft Leg Weight 2.03 _ Bracing Weight 0.00 a Total Member Self - Weight 2.03 0.03 -0.06 , Total Weight 6.14 -0.03 -0.06 Wind 0 deg - No Ice 0.01 -4.46 - 199.23 -0.78 0.29 Wind 30 deg - No Ice 2.25 -3.87 - 172.90 - 100.69 0.17 Wind 60 deg - No Ice 3.88 -2.24 - 100.25 - 173.64 0.00 Wind 90 deg - No Ice 4.48 -0.01 -0.75 - 200.08 -0.17 Wind 120 deg -No Ice 3.87 2.22 98.94 - 172.92 -0.29 Wind 150 deg - No Ice 2.23 3.86 172.11 -99.45 -0.34 Wind 180 deg - No Ice -0.01 4.46 199.16 0.66 -0.29 Wind 210 deg - No Ice -2.25 3.87 172.83 100.58 -0.17 Wind 240 deg - No Ice -3.88 2.24 100.19 173.53 0.00 Wind 270 deg - No Ice -4.48 0.01 0.68 199.96 0.17 Wind 300 deg - No Ice -3.87 -2.22 -99.01 172.81 0.29 Wind 330 deg - No Ice -2.23 -3.86 - 172.18 99.33 0.34 Member Ice 1.90 Total Weight Ice 13.90 0.25 0.43 Wind 0 deg - Ice 0,00 3.24 - 144.59 -0.67 0.04 Wind 30 deg - Ice 1.63 -2.81 - 125.37 -72.95 0.02 Wind 60 deg - Ice 2.82 -1.63 -72.63 - 125.80 0.00 Wind 90 deg - Ice 3.25 -0.00 -0.49 - 145.05 -0.02 Wind 120 deg - Ice 2.81 1.62 71.71 - 125.56 -0.04 Wind 150 deg - Ice 1.62 2.81 124.64 -72.53 -0.04 Wind 180 deg - Ice -0.00 3.24 144.09 -0.19 -0.04 Wind 210 deg - Ice -1.63 2.81 124.88 72.09 -0.02 Wind 240 deg - Ice -182 1.63 72.13 124.93 0.00 Wind 270 deg - Ice -3.25 0.00 -0.01 144.19 0.02 Wind 300 deg - Ice -2.81 -1.62 -72.21 124.69 0.04 Wind 330 deg - Ice -1.62 -2.81 - 125.13 71.67 0.04 Total Weight 6.14_, -0.03 -0.06 :m Wind 0 deg - Service 0.01 -1.77 -79.25 -0.35 0.13 Wind 30 deg - Service 0.89 -1.54 -68.78 -40.08 0.07 Wind 60 deg - Service 1.54 -0.89 -39.89 -69.09 0.00 Wind 90 deg - Service 1.78 -0.01 -0.32 -79.61 -0.07 Wind 120 deg - Service 1.54 0.88 39.32 -68.81 -0.13 Wind 150 deg - Service 0.89 1.53 68.42 -39.59 -0.15 Wind 180 deg - Service -0.01 1.77 79.17 0.22 -0.13 Wind 210 deg - Sery icc -0.89 1.54 68.70 39.95 -0.07 Wind 240 deg - Service -1.54 0.89 39.82 68.96 0.00 Wind 270 deg - Servicc -1.78 0.01 0.25 79.48 0.07 Wind 300 deg - Sery ice -1.54 -0.88 -39.40 68.68 0.13 j I i Job Page tnxTower Blair - NE (114877 -A) 10 of 11 Project Date FDHEngineering, Inc. 1422012400 14:32:51 03/06/14 6521 Meridien Drive, Suite 107 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.- 9197551031 I Load Vertical Sum of Sum of Sum of Sum of Sum of Torques Case Forces Forces Forces Overturning Overturning X z Moments, M Moments, M K K K kip ft ki ft kip ft Wind 330 de - Service 0.89 1.53 -68.49 39.46 0.15 Compression Checks Pole Design Data Section Elevation Size L L„ KI /r A P„ �P„ Ratio No. P" ft f t ft in K K W. L1 60 - 36.67 (1) TP15.425x12.275x0.188 23.33 0.00 0.0 8.801 -4.31 653.84 0.007 L2 36.67-0(2) TP20xl4.6x0.188 40.00 0.00 0.0 11.791 -7.35 863.69 0.009 Pole Bending Design Data Section Elevation Size M, �M- Ratio M W Ratio No. M- M„ ft Idp ft Idp ft �M, kip t kiPft (OM L1 60 - 36.67 (1) TP15.425x12.275x0.188 63.78 197.88 0.322 0.00 197.88 0.000 L2 36.67-0(2) TP20xl4.6x0.188 337.19 351.32 0.960 0.00 351.32 0.000 I Pole Shear Design Data Section Elevation Size Actual V, Ratio Actual (OT Ratio No. V. V T, T ft K K � I n kip ft Idp ft �T LI 60 - 36.67 (1) TPI5.425x12.275x0.188 6.36 326.92 0.019 0.00 396.24 0.000 L2 36.67-0(2) TP20x14.60.188 7.20 431.85 0.017 0.00 703.50 0.000 I Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P„ M„. M V„ T. Stress Stress ft �P ¢M ¢M �V �T, Ratio Ratio Ll 60 - 36.67 (1) 0.007 0.322 0.000 0.019 0.000 0.329 1.000 4.8.2 1 L2 36.67-0(2) 0.009 0.960 0.000 0.017 0.000 0.969 1.000 4.8.2 Job Page A ower Blair - NE (114877 -A) 11 of 11 FDHEngineering, Inc. Project Date 6521 Meridien Drive, Suite 107 1422012400 14:32:51 03/06/14 Raleigh, North Carolina Client Designed by Phone: 9197551012 FMHC Corporation MBrennan FAX.• 9197551031 I I i i I i Section Capacity Table i Section Elevation Component Size Critical P op.11,,, % Pass No ft Type Element K K Capacity F ail L 60-36.67 Pole TP15.425x12.275x0.188 1 -4.31 653.84 319 Pass L2 36.67-0 Pole TP20xl4.6x0.188 2 -7.35 863.69 96.9 Pass Summary Pole (L2) 96.9 Pass RATING = 96.9 Pass Program Version 6.1.4.1 - 12/17/2013 File :C: /Users/MBrennan /Desktop /Current Projects/Blair, NE /Analysis/Blair, NE.eri i I I i I Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding TIA Rev G (1) *(Rod Diameter) Site Data Reactions BU #: Mu: 337 ft -kips Site Name: Axial, Pu: 7 kips App #: Shear, Vu: 7 kips Pole Manufacturer: Other Eta Factor, rl 0.5 TIA G (Fig. 4 -4) Anchor Rod Data 11' No stiffeners, Criteria: I AISC LRFD < -Only Applcable to Unstiffened Cases Qty: 4 Diam: 2.25 in Rod Material: A615 -J Anchor Rod Results Rigid Strength (Fu): 100 ksi Max Rod (Cu+ Vu /I ): 156.1 Kips AISC LRFD Yield (Fy): 75 ksi Allowable Axial, O *Fu *Anet: 260.0 Kips cp *Tn Bolt Circle: 26.81 lin Anchor Rod Stress Ratio: 60.0% a Plate Data Diam: 32.5 in Base Plate Results Flexural Check Rigid Thick: 2 in Base Plate Stress: 29.1 ksi AISC LRFD Grade: 50 ksi Allowable Plate Stress: 45.0 ksi w *Fy Single -Rod B -eff: 15.87 in Base Plate Stress Ratio: 64.7% ` ' & -- Y.L. Length: 17.85 Stiffe Dat (Welding at both side n/a Config: 0 * Stiffener Results Weld Type: Both Horizontal Weld : n/a Groove Depth: 0.3125 in ** Vertical Weld: n/a Groove Angle: 45 degrees Plate Flex +Shear, fb /Fb +(fv /Fv) ^2: n/a Fillet H. Weld: 0.3125 in Plate Tension +Shear, ft/Ft +(fv /Fv) ^2: n/a Fillet V. Weld: 0.3125 in Plate Comp. (AISC Bracket): n/a Width: 10 in Height: 12 in Pole Results Thick: 1 in Pole Punching Shear Check: n/a Notch: 0.5 in Grade:l 50 ksi Weld str.: 70 ksi Pole Data Diam: 20 in c Thick: 0.1875 in o o Grade: 65 ksi o o''t , s , # of Sides: 18 "0" IF Round N Fu 80 ksi ij j ( A Reinf. Fillet Weld 0 °0° if None h •, * 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt ** Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes I i i i CClplate 1.5 - Circular Base G 1.3, Effective March 19, 2012 Analysis Date: 316/2014 j CAISSON Version 10.61 2:34:16 PM Thursday, March 06, 2014 FDH Engineering ******************************************************************* * * * ** * * * * * * * * * * ** * * * * * * * * * ** * ** * * * CAISSON - Pier Foundatinns Analysis and Design - Copyright Power Line Systems, Inc. 1993 -2010 * * Project Title: Blair - NE Project Notes: 1422012400 Calculation Method: Full 8CD * * * * * ** I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength (£t) (ft) (ksi) (ksi) 4.50 0.50 4.00 60.00 Soil Properties Layer Type Thickness Depth at Top Density CU RP PHI of Layer (ft) (£t) (lbs /ft'3) (psf) (deg) - - -------- ---- ---- --- - - - -- --- - - - -- -- - - --- ------ --------- -- -- - - - - -- ° ° - - - -- -- 1 Sand 4.50 0.00 100.0 0.000 88.85 2 Clay 5.50 4.50 100.0 200.0 3 Clay 9.00 10.00 100.0 1000.0 Design (Factored) Loads at Top of Pier Moment Axial Shear Additional Safety Load Load Factor Against Soil Failure (£t -k) (kips) (kips) 337.0 7.0 7.00 2.00 * * * * * ** R E S U L T S i E_4}jQS P�hMA 5IX}n31 L3�n�i4' i6it3 C , (� 3 ; ; i ; 82.33 , ps3 ' 1 4 soiL AF- AcrioN5 wbRmA .SHE CNAGRAM d&C7msh L FDH Engineering Page 1/2 i Calculated Pier Properties Length Weight Pressure Pressure Total Due To Due To End - Bearing Axial Load Weight Pressure (ft) (kips) (psf) (psf) (psf) --------------------------------------------------------------- 19.000 45.327 440.1 2850.0 3290.1 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density CU KP Force Arm to Top of Pier (ft) (ft) (lbs /ft''3) (psf) (kips) (ft) --------------------------------------------------------------------------------------------------- Sand 0.50 4.50 100.0 0.000 0.00 3.50 Clay 5.00 5.50 100.0 200.0 39.60 7.75 Clay 10.50 3.90 100.0 1000.0 140.34 12.45 Clay 14.40 4.60 100.0 1000.0 - 165.66 16.70 Shear and Moments Along Pier Distance below Shear Moment Shear Moment Top of Pier (with Safety Factor) (with Safety Factor) (without Safety Factor) (without Safety Factor) (ft) (kips) (ft -k) (kips) (ft -k) ------------------- -- ---------------- ---- -- ----- -- ------------ ------------- --- -- ---- - -- - -- ---- -- - - - - - -- 0.00 14.3 712.3 7.1 356.1 1.90 14.3 739.4 7.1 369.7 j 3.80 14.3 766.6 7.1 383.3 5.70 9.2 791.9 4.6 396.0 7.60 -4.4 796.5 -2.2 398.3 9.50 -18.1 775.1 -9.1 387.5 11.40 -57.7 716.0 -28.9 358.0 13.30 -126.1 541.4 -63.1 270.7 15.20 -136.8 259.9 -68.4 130.0 17.10 -68.4 65.0 -34.2 32.5 19.00 -0.0 -0.0 -0.0 -0.0 Reinforcement and Capacity Total Reinforcement Usable Usable Reinforcement Area Axial Moment Percent Capacity Capacity --- ---- --------- ----- --- ---- )--- ---(kips)------ (ft_k) 0.38 8.70 7.0 868.3 i US Standard Re -Bars (Select one of the following) Quantity Name Area Diameter Spacing (in''2) (in) (in) ---- ---- 44 ------ #4 - -- 0.20 ---- -- 0.500 ----- - 3.14 29 #5 0.31 0.625 4.77 20 #6 0.44 0.750 6.91 15 #7 0.60 0.875 9.22 12 #8 0.79 1.000 11.52 9 #9 1.00 1.128 15.36 7 #10 1.27 1.270 19.75 6 #11 1.56 1.410 23.04 4 #14 2.25 1.693 34.56 I r FDH Engineering Page 2/2 I ) I i Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces j BU #: TIA Revision: G Site Name: Blair Max. Factored Shaft Mu: 398.3 ft -kips (* Note) App #: Max. Factored Shaft Pu: 7 kips Max Axial Force Type: Comp. * Note: Max Shaft Superimposed Moment does not necessarily Loads Already Factored equal to the shaft top reaction moment For M (WL) 1.3 1 < - - -- Disregard For P (DL) 1.3 < - - -- Disregard Load Factor Shaft Factored Loads 1.00 Mu:j 398.3 ft -kips Pier Properties 1.00 Pu: 1 7 Ikips Concrete: Pier Diameter = 4.5 ft Material Properties Concrete Area = 2290.2 in Concrete Comp. strength, f = 4000 psi Reinforcement yield strength, Fy = 60 ksi Reinforcement: Reinforcing Modulus of Elasticity, E = 29000 ksi Clear Cover to Tie=F In Reinforcement yield strain = 0.00207 Horiz. Tie Bar Size = Limiting compressive strain = 0.003 Vert. Cage Diameter = 3.83 ft ACI 318 Code Vert. Cage Diameter = 46.00 in Select Analysis ACI Code= 1 2008 Vertical Bar Size =® Seismic Properties Bar Diameter = 1.00 in Seismic Design Category = B Bar Area = 0.79 in' Seismic Risk = Low Number of Bars = 18 As Total= 14.22 in Solve < -- Press Upon Completing All Input As/ Aconc, Rho: 0.0062 0.62% (Run) I ACI 10.5 , ACI 21.10.4, and IBC 1810. Results: Min As for Flexural Tension Controlled Shafts: Governing Orientation Case: 2 (3) *(Sgrt(fc) /Fy: 0.0032 E E 200 / Fy: 0.0033 Mu r Mu i Case 1 Case 2 Dist. From Edge to Neutral Axis: 8.05 in Extreme Steel Strain, et: 0.0155 Minimum Rho Check: et > 0.0050, Tension Controlled Actual Req'd Min. Rho: 0.33% Flexural Reduction Factor,cp: 0.900 Provided Rho:F OK i Ref. Shaft Max Axial Capacities, (b Max(Pn or Tn): Max Pu = ((p =0.65) Pn. Output Note: Negative Pu= Tension Pn per ACI 318 (10 -2) 4467.63 kips For Axial Compression, cp Pn = Pu: 7.00 kips at Mu= ((p= 0.65)Mn= 1736.86 ft -kips Drilled Shaft Moment Capacity, cpMn: 1437.64 ft -kips Drilled Shaft Superimposed Mu: 398.30 ft -kips Max Tu, ((P =0.9) Tn = 767.88 1kips at Mu= �)= (0.90)Mn= 0.00 ft - kips (Mu /cpMn, Drilled Shaft Flexure CSR: 1 27.7% Drilled DSMC, Version 1.1 - Effective 04/01/ 2010 Analysis Date: 3/6/2014 i I I r i I w p A w a m m a i � I � v ( m a! a a n a i a c c 3 c i U U' m N a N O a F w x x x x x I I i Q Q � x x x x x x m � O 0 Q � '� — a 1p =LLt ° `o oII i w z c Q 9 z E W 0 A ° wT s� C O y ¢ °O /Vr C T C d U! d laq ° 1 A c W a a O O W N m ` 7 '� U 'a a ¢ y 10 O v a a > y v = a c tQ w a. 'g uai F q c c sww U 3 w '� k t1 Y g E Q a- h M v w w � a o a 0 NaE ca n n o E a>, mo y o c� W R7 La N ° p O . a a rn '�° ¢ °Oc mm am 0 y d a O A a•yQ E' a a v � Q'o ow o o v m : o ur o o. 'p cc G! Gl C T w N S' ` N d Of N > W x J C y (1) a N O O 6 D Q ¢ N W Y N N o f 6 a Q I I� w N C E E U Z Ell MEMO z mom Emil MEN NONE r mom NINE Emil no W a u c 1 V Nil 1111111111 R d a a z c Q o �o Nil 11111111111 m U c • N y G _ o !o 0 y C y C d C 0a !0 a 0a c E e E C E • z. IC O) R CI R OI O v � w u m LU U W W W • Z O y 0 U" j3 03 jN u c u v s • v c C' ac d� c 3 Q 3 O 0 O d: O 0 O; 0 0 p A p i i I i i I i I Z wm Q �'a8d a v gd L 00 'e m -o c I Q ' i i W � L O y � � I k � �I i' ELL ELL E Va U U 0 0 o a e e e ¢ N a M : a � U Q Q 4 M 1p 10 C° r N C G G I d N M V O D 0 v o d d 7 U J N J N J L EE E a o N o M o m � E; E E a > E .E .E % % X p N N ic 2 o, e m 'E m 'ui c a n rn a m N G m c C- � 11 IL a W F- m L LL d r ,E r N � � � I N I 3 I E � % a � w v v C � U w 3 ° J C w r m m m N Z C7 Ci a G r N p t C O M - U r L L Z 3 E N�7 N E_ q I cq r r ti J _ uj m 2 — V N ti E o rti o v v v P w rn w o m o m p ° C C U U C °�ia3N o o "m Z222S �p LU o v m m E x o ° u0 K M X M U DU J (m �U)w F a v)KK D' K� v 0 m Ya QQ Qaa K Idd ° z F �Q c F �xxxx No IL m / r V/ C m O w o U U U LL Z Z a N N a h N H H J N N ¢ t9 w v E « 0 oe. om '°rn o� W 0 2 N:� Z 7 N Z Z Z o Q N co L �•°. `v ma � m mcv —01 °� a�� •«Nm v K .� ,. v ' m E� Q G c F 2 O N 7 j d Z Z Z N m N N N N N N= O N= N N L w N Nj oi1 G. 4f' NS NS W F7 Ml o 0 0 0 0 0 0 o d o E o w o !� n. w h f E F F H �- f F F °, c I — t�v�in�oo w Naaa w as LL a - aaaaaaa I i i I