Loading...
2028 Kellie Dr.jpg Phil Green (Blair, NE) From: Phil Green (Blair, NE) Sent: Wednesday, November 20, 2013 3:50 PM To: 'Dustin Tomoson' Cc: Brenda Wheeler; Howard Wolfe Subject: RE: Casey's -2028 Kellie Dr -cn- 2013 -00543 Dustin, Following our conversation this morning, and my review of the submitted plans and civil plans, see my notes below in RED regarding the status of these 9 issues. Please be specific regarding items which will be deferred. None of these items should delay the issuing of the actual pen Once we receive information regarding the general contractor, the building permit will be ready to issue. Phil Green Assistant City Administrator City of Blair 218 South 16th Street Blair, NE 68008 Phone: (402) 426 -6691 Fax: (402) 426 -4195 PCGreengci.blair.ne.us From: Howard Wolfe Sent: Tuesday, November 19, 2013 5:18 PM To: Dustin Tomoson Cc: Phil Green (Blair, NE); Brenda Wheeler; Howard Wolfe; Rodney Storm Subject: Casey's -2028 Kellie Dr -cn -2013 -00543 Date: 11 -19 -2013 Re: Plan Review Notice for Casey's new store, Blair, N.E. Please respond to the following comments: 1. Sheet AL -501 shows the canopy footings at 3'0" below grade. Please show at 42" minimum. (Dustin will submit a revised drawing) 2. Provide Civil drawings. Show elevations, silt fences, grading, sidewalks, storm drainage, etc. (City had already received civil plans. They have been approved and are ready to pi ck up. No further changes are required.) 3. Sheet A -402: Show a portion of the sales counter at a maximum 36" above the floor and a minimum of 36" long. (A note was included on the page which said the 7" riser would not be installed. The drawing is approved and no further changes are required.) i 4. Show the location of the emergency disconnect for the pumps as per section 2203.2 of the IFC, 09'. (The location is show on sheet G -011. Outside shutoff is on west side of lot. Inside shutoff is also shown. The drawing is approved and no further changes are required.) 5. Provide plans for typed hood fire suppression system (Sheet M -401 shows the Type 1 hood. Additional details regarding the fire suppression system inside the hood are also required. These plans can be deferred until just prior to installation.) 6. Provide sign permit application and wall sign attachment details. Contact Brandy at 402- 426 -4191. (Sign details [size, location, etc.] and attachment details [how attached and to what material] must be provided at time of application. Information can be sent through mail or email.) 7. List required Special Inspections on the plans as per Chapter 17, IBC09'. (If no Special Inspections are required, please specify that in writing via email or letter.) 8. Provide mechanical and plumbing permit applications. Contact Brandy at 402 - 426 -4191. (Mechanical and Plumbing contractor should contact Brandy directly.) 9. Show the location of a key box on the plans. This is typically located near the front entrance. We will attach a key box application to the approved plans. (This drawing can be deferred until just prior to installation.) Thank you, Howard Wolfe Building Inspector City of Blair 218 South 16th Street Blair, NE 68008 Office: (402) 426 -4191 Direct: (402) 426 -6696 Fax: (402) 426 -4195 hwolfe @ci.blair.ne.us 2