re-2011-00281_0005.jpg COMcheck Software Version 3.8.0
Interior Lighting Compliance
Certificate
2006 IECC
Section 1: Project Information
Project Type: Addition
Project Title :
Construction Site: Owner /Agent: Designer /Contractor:
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B x C)
Dining: Family 1780 1.6 2848
Total Allowed Watts = 2848
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
Dining: Family (1780 sq.ft.)
Linear Fluorescent 1: 1/1E: 48" T8 32W / Electronic 3 10 95 950
Linear Fluorescent 1 copy 1: 1 A: 48" T8 32W / Electronic 2 1 65 65
Incandescent 3: 5 - restrooms: 5 / Incandescent 60W 1 6 60 360
Compact Fluorescent 1 copy 1: goose: 7 / Other / Electronic 1 3 5 15
Incandescent 3 copy 1: 13 - cashwrap: 13 / Incandescent 60W 1 10 60 600
Incandescent 5: track #1,2: 480W curcuit limiter / Other 1 1 480 480
Incandescent 7 copy 2: track #3,4,5,6,7: 120w circuit limiter / Other 1 1 120 120
Incandescent 7 copy 3: track #8 & 9: 240w circuit limiter / Other 1 1 240 240
Total Proposed Watts = 2830
Section 4: Requirements Checklist
Lighting Wattage:
Ej 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Watts Proposed Watts Complies
2848 2830 YES
Controls, Switching, and Wiring:
F1 2. Independent controls for each space (switch /occupancy sensor).
Exceptions:
F Areas designated as security or emergency areas that must be continuously illuminated.
Lighting in stairways or corridors that are elements of the means of egress.
Li 3. Master switch at entry to hotel /motel guest room.
F1 4. Individual dwelling units separately metered.
F1 5. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either
controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle
lamp luminaires independently of other lamps, or switching each luminaire or each lamp.