sd-2011-00311_0002-1.jpg 2118107
Sin Resi D ecks a nd P
New or existing Open guardrails on decks more than 30 inches above grade or a floor below shall
light required Y have members spaced so that a 4 inch diameter sphere cannot pass through.
Stairway Notes:
Guardrail 1. Stairways shall be not less than 36" in width.
Openings for required 2. Stairway rises shall be not greater than 7 3/4 ".
guards on the sides 3. Stairway treads shall have a minimum run of 10 ".
of stair treads shall 4. The length of Run and the height of Riser shall not
not allow a 4 3/8" vary more than 3/8" in the entire run of the stair.
diameter sphere to 5. Stairs are required to be illuminated.
36" min. pass through. 6. Open risers permitted if opening is less than 4 ".
height 7. A nosing not less than 3/4" but not more than 1 1/4"
shall be provided on stairways with solid risers, and
less than 11 ".
8. Composite materials (example:Trex) may require 4
y
stringers
Deck 34 -38" above
Less than nosings
6" dia. Handrail (see details below)
1
Guardrail required if 10" min. run
more than 30" from nosing
to nosing
Landing same
open risers
p 36" Min. width as stairs
less than 4"
7 3/4 max. rise „LL Finished grade
Handrail Notes:
1. Handrails shall be continuous on at least one side of stairs with 4 or more risers.
2. Top of the handrails shall be placed not less than 34 inches nor more than 38 inches above stair nosings.
3. The handgrip portion of handrails shall be not less than 1 -114 inches nor more than 21/4 inches in cross section for non circular handrails.
4. Handrails shall be placed not less than 1 -112 inches from any wall or other surface.
5. Handrails to be returned to wall, post or safety terminal (per 311.5.6.2 IRC)
unacc eptable . •
Type II Type I
,I � 1 'A" - 2 /a" max. 1 -' /z" min. —�
3 /4
'
1 /a 1 ' /a" - 2" Gripable
3
�::[ Af-- Wall or other surface
f 1 ' /z" min.
4