sd-2011-00085_0005.jpg Significant Changes to the IRC 2009 Edition R502.2.2.1 AND TABLE R502.2.2.1 ® Deck Ledger Connection 127 TABLE R502.2.2.1 Fastener Spacing for a Southern Pine or Hem -Fir Deck Ledger and a 2 -Inch Nominal Solid -Sawn Spruce- Pine -Fir Sand Joist I (Deck Live Load= 40 psf, Deck Dead Load= 10 psf) oist S an 6' -0" and 6' -1" to 8' -1" to 10' -1" to 12' -1" to 14' -1" to 16' -1" to Less 8' -0" 10' -0" 12' -0" 14' -0" 16' -0" Connection Details On- Center Spacing of Fasteners ee 1 /z "- diameter lag screw with 30 23 18 15 13 11 10 15/32" maximum sheathing 1 /z "- diameter bolt with 15/32" 36 36 34 29 24 21 19 maximum sheathing lh "- diameter bolt with 15/32" 36 36 29 24 21 18 16 maximum sheathing and 1 /z" — — — — — stacked washers hh For SI: 1 inch = 25.4.1 foot = 304.8 mm. 1 pound per square foot = 0.0479 kPa. A. The tip of the lag screw shall fully extend beyond the inside face of the band joist. b. The maximum gap between the face of the ledger board and face of the wall sheathing shall be 1 h." c. Ledgers shall be flashed to prevent water from contacting the house band joist. A. Lag screws and bolts shall be staggered in accordance with Section R502.2.2.1.1. e. Deck ledger shall be minimum 2 X 8 pressure- preservative - treated No. 2 grade lumber or other approved materials as established by standard engineering practice. L When solid -sawn pressure - preservative- treated deck ledgers are attached to a minimum 1 inch thick engineered wood product (structural composite lumber, laminated veneer lumber, or wood structural panel band joist), the ledger attachment shall be designed in accordance with accepted engineering rap ctice. S. A minimum 1 by 9 1 h Douglas Fir laminated veneer lumber rimboard shall be permitted in lieu of the 2 -inch nominal band joist I Wood structural panel sheathing, gypsum board sheathing or foam sheathing not exceeding 1 inch in thickness shall be permitted The maxi- mum distance between the face of the ledger board and the face of the band joist shall be 14nch. i RS02.2.2.1.1 Placement of Lag Screws or Bolts in Deck Ledgers. The lag screws or bolts shall be placed 2 inches (51 mm) in from the bottom or top of the deck ledgers and between 2 and 5 inches (51 and 127 mm) in from the ends. The lag _screws or bolts shall be staggered from the top to the bottom along the horizontal run of the deck ledger. i RS02.2.2.2 Alternate Deck Ledger Connections Deck ledger connections not conforming to Table R502.2.2.1 shall be designed in accordance with accepted engineering practice Girders supporting deck joists shall not be supported on deck ledgers or band joists Deck ledgers shall not be supported on stone or masonry veneer. RS02.2.2.3 Deck Lateral Load Connection. The lateral load connection required by Section R502 2 2 shall be permitted to be in accordance with Figure R502.2.2.3. Hold -down tension devices shall be provided in not less than two locations per deck and each de- vice shall have an allowable stress design capacity of not less than 1500 pounds (6672 N) CHANGE SIGNIFICANCE: In the 2006 IRC, floor construction must k be capable of accommodating all loads, and the deck provisions of Section R502.2.2 require positive connection to the primary strut - Lure to resist both vertical and lateral loads. Other than those perfor- mance requirements and the mention that nails subject to withdrawal were not satisfactory for the connection, the 2006 IRC contained no R502.2.2.1 and Table R502.2.2.1 continues i