Loading...
pb-2011-00260_0003.jpg Wick Buildin4s Reference Manual Material Specifications Gable Pitched Buildings w , s Spacing • Other 1' -0" increments up to 12'. Check • /B' on center bays. pages RC -1 – RC -3 in Roof Construction section for truss requirements. Footings • Other poured sizes to be code compliant. • 4' – 60' span = 3' /2" x 14" precast concrete. Refer to Footing Size Design, Page FD -8 • 63'– 90' span = 6" x 18" poured concrete. Builder to provide with material in Foundation section. only buildings. Sidewall Columns • Larger sizes. • All CCA treated to .6 # /ft see chart on next page). • Solid sawn columns. Endwall Columns • Larger sizes. • 24' – 90' span = 3 ply 2x6 standard laminated column. • Solid sawn columns. Treated Uplift Anchors • 1 /2" rebar and 80# Ready- Crete. Two treated blocks per column. Treated Plank N/A • 2x8 S4S #1 SYP AWPA treated for ground contact Guts M -23 SYP 2x6 1650 MSR SPF • RLC -F, SLC -I and others. Refer to Roof asses SLC -F. Construction section or Technical Sales • SSG � ' for designs. Truss -to- Column Connection • Two (2) 3 /4" bolts versus 1 /2" standard. L' • Two 2 1 /2" bolts w/ eight 8 16d nails. Truss center - notched into column. veled Purlin N/A • 2x6 beveled eave purlin. urlins • 2x4 at other centers. • All 2x4 MSR 1650 (SPF) purlins @ 24 on center. • 2x4 using other species. • 2x6 dropped between trusses. Z- Corner Bracing • — Option to add on Wand 9' ICH's. • — 2x4 corner braces none required on B'or 9'interior dear heights ). • Convert to M's. Knee Bracing (Refer to bracing note on previous page.) . Option to add 2x6 @ 45 • None required, ower Chord Stabilizers • 2x4. N/A Wind Bracing (roof line) • Option to add on 24', 27', 30' and 36' • 2x4 wind braces (None required on 24', 27', 30', and 36' spans.) (Refer to spans. drawing on next pa ,7e.) • Option to increase to heavier bracing. Wick Panel (steel) • Roof and sides 29 gauge steel grade E, G -90 galvanized, 1 -1/2 mil Ceram - A -Star siliconized polyester paint system. One -piece metal roofing panels, up to 36' max. length. (i.e., 66' span with a 12" overhang.) • 29 gauge Acrylume All one -piece metal roofing panels and sidewall panels are fastened with 1" • Wood sidings and shingled roof. #9 Woodgrip screws. All metal roofing panels which are two -piece and greater are fastened with 1 -1/2" Woodgrip screws. Screw lengths are adjusted accordingly for panels placed over insulation. Slide Doors 42WD wood frame (with or without 5'x5' • Steel frame. tempered lass. 4" added to the nominal ICH to provide for optional concrete flooring. N/A Spans . Any size above, below or in between. • 24' 27 30' 6' 40' 42' 45' 48' 51' 54' 60' 63', 66' 69' 72' 81' 90' Pi • 3/12 ` .5/12 4/12 •Higher or lower, including attic trusses. I • r 8'-4',9'-4", 10' -4 ", 11'-4" 12'-4", 13' -4 ", 14' -4 ", 15' -4 ", 16' -4 ", 17' -4 ", 18' -4 ", • Other 1' increments. 19'-4" 20' -4" Length Adjustable length by bay size to required • Standard is a 72' base. length. Page CE -3 February 2011