ps-2011-00070_0001 (2).tif OPERATION PNEUMATIC ELECTRIC HYDRAULIC PIPING SUPERVISED _ YES _ NO DETECTING MEDIA SUPERVISED _ YES _ NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND /OR REMOTE CONTROL STATIONS _ YES NO DELUGE & IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO, EXPLAIN PREACTION YES NO VALVES MAKE MODEL DOES EACH CIRCUIT DOES EACH MAX TIME TO OPERATE SUPERVISION CIRCUIT OPERATE OPERATE RELEASE LOSS ALARM VA. RELEASE YES NO YES NO MIN SEC„ HYDROSTATIC Hydrostatic tests shall be made at not less than 200psi (13.6 bars) for two hours or 50psi (3.4 bars) above static pressure excess of 150psi (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during the TEST test to prevent damage. All above ground piping leakage shall be stopped. ' DESCRIPTION PNUEMATIC Establish 40psi (2.7 bars) air pressure and measure drop which shall not exceed 1- 1 /2psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1 -1/2 si 0.1 bars in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR _2_ HOURS IF NO, EXPLAIN DRY PIPING PNUEMATICALLY TESTED _x YES NO EQUIPMENT OPERATES PROPERLY _x YES NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OR SODIUM OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE TESTS NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? _x_ YES NO DRAIN READING OF GAUGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST TEST SUPPLY TEST CONNECTION PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. OTHER EXPLAIN VERIFIED BY COPY OF THE U FORM 85B _x YES NO By Others FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING _x YES NO BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKET 0 WELDED PIPING _x — YES NO IF YES.... -DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.0. LEVEL AR -3 _X YES NO -DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWSD 10.9 LEVEL AR -3 X YES NO -DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED _X YES NO CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS ARE RETRIEVED? (DISCS) _X — YES NO HYDRAULIC NAME PLATE PROVIDED IF NO, EXPLAIN NAME PLATES X YES NO REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: ASSOCIATED FIRE PROTECTION TESTS WITNESSED BY: F ROPERTY OW ER: TITLE: DATE: C SIGNATURES FOR P INKLE ONT TO TITLE: DATE: ADDITIONAL EXPLANATIONS AND NOTES 0 TTACHED SHEET