ac-2011-00128_0003.jpg Material Wick Buildings Reference Manual e
Gable Pitched Buildings
t
Spacing Other 1' -0" increments up to 12'. Check
• 9' on center bays. pages RC -1 – RC -3 in Roof Construction
section for truss requirements.
Footings
� 24' – 60' span = 3 x 14" precast concrete. Other poured sizes to be code compliant.
•
63'– 90' span = 6" x 18" poured concrete. Builder to provide with material Refer to Footing Size Design, Page FD -8
in Foundation section.
only buildings.
Sidewall Columns • Larger sizes.
• All CCA treated to .6 # /ft see chart on next page). • Solid sawn columns.
Endwall Columns • Larger sizes.
• 24' – 90' span = 3 ply 2x6 standard laminated column. • Solid sawn columns.
Treated Uplift Anchors . 1 /2" rebar and 80# Ready- Crete.
L . Two treated blocks per column.
Treated Plank N/A
G • 2x8 S4S #1 SYP AWPA treated for ground contact
Girts M -23 SYP
• 2x6 1650 MSR SPF
Trusses • RLC -F, SLC -I and others. Refer to Roof
L SLC -F. - �.LGTI'��`����'�� Construction section or Technical Sales
for designs.
Truss -to- Column Connection • Two (2) 3 /4" bolts versus 1 /2" standard,
• Two 2 1 12" bolts w/ eight 8 16d nails. Truss center - notched into column.
Beveled Purlin N/A
• 2x6 beveled eave purlin.
Purlins • 2x4 at other centers.
L All 2x4 MSR 1650 (SPF) purlins @ 24" on center. • 2x4 using other species.
• 2x6 dropp ed between trusses.
Corner Bracing • — Option to add on 8' and 9' ICH's.
• — 2x4 corner braces none required on 8'or 9'interior clear hei hts . • Convert to M's.
Knee Bracing (Refer to bracing note on previous page.) . Option to add 2x6 @ 45'.
• None required.
Lower Chord Stabilizers N/A
• 2x4.
Wind Bracing (roof line) • Option to add on 24', 27', 30' and 36'
• 2x4 wind braces (None required on 24', 27', 30', and 36' spans.) (Refer to spans.
drawing on next page.) • Option to increase to heavier bracing.
W' k Panel (steel)
• Roof and sides 29 gauge steel grade E, G -90 galvanized, 1 -1/2 mil Ceram -
A -Star siliconized polyester paint system.
One -piece metal roofing panels, up to 36' max. length. (i.e., 66' span with
a 12" overhang.) • 29 gauge Acrylume
All one -piece metal roofing panels and sidewall panels are fastened with 1" • Wood sidings and shingled roof.
#9 Woodgrip screws.
All metal roofing panels which are two -piece and greater are fastened with
1 -1/2" Woodgrip screws.
Screw lengths are adjusted accordingly for panels placed over insulation.
Slide Doors 42WD wood frame (with or without 5'x5'
• Steel frame. tempered lass.
4" added to the nominal ICH to provide for optional concrete flooring. N/A
Spa - . Any size above, below or in between.
• 24' 27' 30' 36' 40' 42' 45' 48 51' 54' 60' 63' 66' 69' 72' 81' 90'
Pitch
• 3/1 3.5/12 4/12 •Higher or lower, including attic trusses.
ICH
• + 8' -4 ", 9'-4 ", 10' -4 ", 11'4', 12' -4 ", 13' -4 ", 14' -4 ", 15' -4 ", 16' -4 ", 17' -4 ', 18' -4 ", • Other 1' increments.
ITT" 20' -4"
Length a Adjustable I lyto required
• Standard is a 72' base. ,27 length. v
APR 15 20
CITY Ore