Loading...
ac-2011-00128_0003.jpg Material Wick Buildings Reference Manual e Gable Pitched Buildings t Spacing Other 1' -0" increments up to 12'. Check • 9' on center bays. pages RC -1 – RC -3 in Roof Construction section for truss requirements. Footings � 24' – 60' span = 3 x 14" precast concrete. Other poured sizes to be code compliant. • 63'– 90' span = 6" x 18" poured concrete. Builder to provide with material Refer to Footing Size Design, Page FD -8 in Foundation section. only buildings. Sidewall Columns • Larger sizes. • All CCA treated to .6 # /ft see chart on next page). • Solid sawn columns. Endwall Columns • Larger sizes. • 24' – 90' span = 3 ply 2x6 standard laminated column. • Solid sawn columns. Treated Uplift Anchors . 1 /2" rebar and 80# Ready- Crete. L . Two treated blocks per column. Treated Plank N/A G • 2x8 S4S #1 SYP AWPA treated for ground contact Girts M -23 SYP • 2x6 1650 MSR SPF Trusses • RLC -F, SLC -I and others. Refer to Roof L SLC -F. - �.LGTI'��`����'�� Construction section or Technical Sales for designs. Truss -to- Column Connection • Two (2) 3 /4" bolts versus 1 /2" standard, • Two 2 1 12" bolts w/ eight 8 16d nails. Truss center - notched into column. Beveled Purlin N/A • 2x6 beveled eave purlin. Purlins • 2x4 at other centers. L All 2x4 MSR 1650 (SPF) purlins @ 24" on center. • 2x4 using other species. • 2x6 dropp ed between trusses. Corner Bracing • — Option to add on 8' and 9' ICH's. • — 2x4 corner braces none required on 8'or 9'interior clear hei hts . • Convert to M's. Knee Bracing (Refer to bracing note on previous page.) . Option to add 2x6 @ 45'. • None required. Lower Chord Stabilizers N/A • 2x4. Wind Bracing (roof line) • Option to add on 24', 27', 30' and 36' • 2x4 wind braces (None required on 24', 27', 30', and 36' spans.) (Refer to spans. drawing on next page.) • Option to increase to heavier bracing. W' k Panel (steel) • Roof and sides 29 gauge steel grade E, G -90 galvanized, 1 -1/2 mil Ceram - A -Star siliconized polyester paint system. One -piece metal roofing panels, up to 36' max. length. (i.e., 66' span with a 12" overhang.) • 29 gauge Acrylume All one -piece metal roofing panels and sidewall panels are fastened with 1" • Wood sidings and shingled roof. #9 Woodgrip screws. All metal roofing panels which are two -piece and greater are fastened with 1 -1/2" Woodgrip screws. Screw lengths are adjusted accordingly for panels placed over insulation. Slide Doors 42WD wood frame (with or without 5'x5' • Steel frame. tempered lass. 4" added to the nominal ICH to provide for optional concrete flooring. N/A Spa - . Any size above, below or in between. • 24' 27' 30' 36' 40' 42' 45' 48 51' 54' 60' 63' 66' 69' 72' 81' 90' Pitch • 3/1 3.5/12 4/12 •Higher or lower, including attic trusses. ICH • + 8' -4 ", 9'-4 ", 10' -4 ", 11'4', 12' -4 ", 13' -4 ", 14' -4 ", 15' -4 ", 16' -4 ", 17' -4 ', 18' -4 ", • Other 1' increments. ITT" 20' -4" Length a Adjustable I lyto required • Standard is a 72' base. ,27 length. v APR 15 20 CITY Ore Page CE -3 NEBRASh4 February 2011