ac-2011-00104_0005.jpg Wick Builrlinas Reference Manual ` Material Specifications Gable Pitched Buildings � i' ]/V Spacing • Other 1' -0" increments up to 12'. Check 9' on center bays. pages RC -1 - RC -3 in Roof Construction section for truss requirements. Footings • Other poured sizes to be code compliant. • 24' - 60 span = 3' /2 x 14 recast concret Refer to Footing Size Design, Page FD -8 • 63' - 90' span = 6" x 18" poure concrete, Builder to provide with material in Foundation section. onl idewall Columns • Larger sizes. • All CCA treated to .6 # /fe see chart on next a e . • Solid sawn columns. Endwall Columns • Larger sizes. • 24' - 90' s an = 3 1 2x6 standard laminated column. • Solid sawn columns. Treate c ors • 1 /2" rebar and 80# Ready Crete. • o treated blocks er column. Treated Plank N/A 2x8 S45 Al SYP AWPA treated for ground cont Girts M -23 SYP • 2x6 1650 MSR SPF Trusses y� • RLC -F, SLC -I and others. Refer to Roof �`xC 0- Construction section or Technical Sales • SLC -F. for designs. Truss -to- Column Connection . Two 2 1 /2" bolts w eight 8 16d nails. Truss center - notched into column. 'Two (2) 3 /a bolts versus �/2" standard. Beveled Purlin N/A 2x6 beveled eave purlin. • 2x4 at other centers. Purlins • 2x4 using other species. • All 2x4 MSR 1650 (SPF) purlins @ 24 on center. • 2x6 dropped between trusses. Corner Bracing • — Option to add on 8' and 9' ICH's. • - 2x4 corner braces none required on 8'or 9'interior dear heights). • Convert to M's. Knee Bracing (Refer to bracing note on previous page.) • Option to add 2x6 @ 45 ° . • None required. Lower Chord Stabilizers N/A _—r 2x4. Wind Bracing (roof line) • Option to add on 24', 27', 30' and 36' • 2x4 wind braces (None required on 24', 27', 30', and 36' spans,) (Refer to spans. drawing on next a e. ) • Option to increase to heavier bracing. Wick Panel (steel) • Roof and sides 29 gauge steel grade E, G -90 galvanized, 1 -1/2 mil Ceram - A -Star siliconized polyester paint system. One -piece metal roofing panels, up to 36' max. length. (i.e., 66' span with a 12" overhang.) • 29 gauge Acrylume All one -piece metal roofing panels and sidewall panels are fastened with 1" • Wood sidings and shingled roof. #9 Woodgrip screws. All metal roofing panels which are two -piece and greater are fastened with 1 -1/2" Woodgrip screws. Screw lengths are adjusted accordingly for panels placed over insulation. Slide Doors 42WD wood frame (with or without 5'x5' • Steel frame. tem eyed lass. 4" added to the nominal ICH to provide for optional concrete flooring. N/A Spans . Any size above, below or in between. • 2 27' 30' 36' 40' 42' 45' 48' 51' 54' 60' 63' 66' 69' 72' 81' 90' Pi • 3/12 .5/12 4/12 • Higher or lower, including attic trusses. I - • • Other 1' increments. 19'-4" 20' -4" Length • Adjustable length by bay size to required • Standard is a 72' base. length. Page CE -3 February 2011