Loading...
ad-2010-00276_0008.jpg 4x4 POST WITH REQUIRED NOTCHING SHOWN. SUNRO DETAILS SEE GENERAL NOTES ON SHEET 1 FOR FOR 4x6 AND 6x6 POST, STOP FLOOR ANCHORING NOTE: 8 -0091 a�n' ° uw101 U REQUIREMENTS FOR PRESSURE TREATED �ii pi LUMBER AND FASTENERS. EXPANDER (1 -2056) ON EACH SIDE OF FOR WOOD USE: MIN. (2) 3/8" DIAM. .�� s, `� RIDGE POST x 3 -1/2" LONG GALVANIZED LAGS 1 -2092 W/ 2 -1/2' x o ° °�y \�• °' " ° ° °•� (2) — #10 x 2" TEK SCREWS NOTCH BOTTOM OF RIDGE POST TO (MIN. 1 -1/2" EMBEDMENT INTO 2 -1/2" x 3/16" THROUGH INTERIOR FACE OF CLEAR WEEP SHELF & FLOOR EXPANDER STRUCTURAL FRAMING) :;� (STEEL TUBE (8 -0091) �; Z e " "` `� "" LENGTH OF STEEL TUBE = �' <— N ' FLOOR EXPANDER (1 -2056) Rid9 (1 -2056) SIDEWALL (4x4 POST ONLY) PpS FOR CONCRETE USE: INSERT TO BE EXACTLY = J. ® W 2 al INTO RIDGE POST �• ' " r 4~ REMOVE INTERIOR LIP OF FLOOR (2) 3/8 " DIAM. x 3 WEDGE —BOLT SAME AS AV UTILITY POST) °cy2:• w EXPANDER (1 -2056) AT POST LOCATION % Oa' 3/8" DIAM. x 3 -1/2 LONG GALVANIZED LAG WITH WASHER I /z~ o ° 3/8 DIAM. x 3 WEDGE —BOLT; EACH SIDE OF RIDGE POST TYP. EACH SIDE OF RIDGE POST 1 ����wuiuun+ ON WOOD FOUNDATIONS ON CONCRETE FOUNDATION • •I 1 -2053 (3) #10 x 1 -1/4" TEK I I • NOTE: LOCATE LAGS /BOLTS 3/8• " • IN HOLE CLOSEST TO 2 -1 /2 ANGLE BRACKET I� a 0 SCREWS THROUGH WALL � _j w INTERIOR OF ROOM; TYPICAL • • (8- 2108A). TYP. AT EACH POST SUPPORT BRACKET o � I` HE L. a SIDE OF RIDGE POST (1 -2053) INTO UTILITY n o w ° — • � • 0 e• \ OQZ W PLYWOOD OR OSB FLOOR EXPANDER (1 -2056) POST (1- 2092), TYPICAL z Q F c ,, >o� DECK SURFACE o O UP FLUSH WITH AT EACH SIDE OF POST > o Z o ix a� EDGE OF CONCRETE ON (2) #8 x 1 /2" TEK SCREWS m 1 -2056 co NCa a CONCRETE FOUNDATION ° Z o 13, °w Mn FOUNDATION' Z O 3 ui ' N W� SHOWN �' � a w < N 0_0 ix TRUGRIP ANCHORS ° a , (2) #10 X 2" TEK SCREWS ° J o w > N a U- @ 18" O.C. TYP. THROUGH FLOOR EXPANDER (1 -2056) o z STAGGERED Decx INTO RIDGE POST , ALUM. FLASHING .2 FO SHOWN " (4) — #10 x 2" LONG TEK SCREWS AT EACH BRACKET; TYP. ® � o ° (2) #8 x 1/2" TEK SCREWS c� o w . FLOOR EXPANDER (1 -2056) LIP 1 -2056 THROUGH FLOOR EXPANDER z a C o OVERHANGS WOOD HEADER (1 -2056) INTO SIDEWALL LIPS N w z = BY 1/2" ON DECK FOUNDATIONS OF UTILITY POST (1 -2092) C= 3 = o »A WOOD RIDGE POST AN CHORAGE »B AV UTILITY RIDGE POST ANCHORAGE vz o . 9 A FLOOR EXPANDER g AT��N BOOREXPANDER dw wo ( BOTH WOOD DECK & CONCR FOUNDATION SHOWN) ( FOUNDATION SHOWN) z (WOOD POST SHALL BE PRESSURE TREATED FOR CONCRETE FOUNDATION) G L j MIN. 3/8" DIAM. x 2-1/2" LONG .W°� WOOD RIDGE BEAM GALVANIZED LAG W /WASHERS INTO 9° o�Z�� 3 ", 4 -5/8" OR 6" PANEL SIZE AND NUMBER OF ®D PEEBEAE AS SPECIFIED - l ' HANGER (3" SHOWN) (1 -0210) MEMBERS AS SPECIFIED °`__° BY P.E.I. ENGINEERING ALUMINUM FLASHING� N � [ ? y �� ALUMINUM FLASHING AS REQUIRED��W == - 1 0209 #8 x 1 /2 TEK SCREWS, — a • `' ~ ' �' - " -• "• TYP. BOTH SIDES (2) INTO EACH I NECTING PANELS; TYP. AT 1 -0 W —BEAM (1- 02178) CON ., 210 BOTH TOP AND BOTTOM OF ROOF ° W s W W p O p= 3" 4 -5/8" OR 6" ° ROOF PANEL F t p W° ZW V11 (3" SHOWN) THERMAL BREAK #8 x 1/2" TEK SCREWS, °� (n (2) INTO EACH I —BEAM (1- 02178) Q _j CONNECTING PANELS; TYP. AT P.E.I. 8" (1 -0229) OR ICY_ Q BOTH TOP AND BOTTOM OF ROOF 6" (1 -0218) ALUMINUM 3 ", 4 -5/8" OR 6" ROOF PANEL Q Z [— RIDGE BEAM " 8 SHOWN ® w Lu ( ) (3" SHOWN) ALUMINUM FLASHING AS REQUIRED z Q 18A ALUMINUM RIDGE BEAM 188 WOOD RIDGE BEAM w g AND PANEL HANGER g M AND w Q TAB AND PANEL HANGER Q SHEET 9 OF II