Loading...
ad-2010-00276_0005-1.jpg # x 1/2" TEK SCREWS; TEMPERED GLASS SUNROOM DETAILS 1 -2074 BOTH SIDES AT PANEL CAP (1 -2035) 1 -2062 ��e�`��C \��• AND H SUPPORT (1- 2080A) 1-20098 # x 1 " TEK SCREWS ® TOP, , 1 3r TEMPERED GLASS BOTTOM w Q / d UP, & 1 /3rd DOWN 3" NOMINAL �� • - THICKNESS FOAM Q (2) #8 x 1/2" TEK SCREWS THROUGH FLOOR '.' WING PANEL EXPANDER (1 -2056) INTO HD CORNER POST " 1 -0121; z (1- 2078A) FROM OUTSIDE AND INSIDE FACE CONTINUOUS OF WALL. TYP. AT EACH SIDE OF POST '= _ CO 1 -2044 ANCHORS ® INTERMEDIATE LOCATIONS EXTERIOR SIDE 1- 208OA; I m # x 1/2" TEK SCREWS CONTINUOUS X Z LELAND INDUSTRIES GP FASTENERS; #10 ® TOP, BOTTOM & 16 O.C. pp�� w 0 LELAND GP x 2 -INCH LONG SCREWS WITH DT -1700 2 P LAN VIEW OF GLASS OC FASTENER AoONG TIN EXPANDERS S (1 2056)0 TYP. M o a o e �' \ H } Q FOAM WING PANEL 3 NOMINAL THICKNESS ^ o Z ko FOAM KNEEWALL z o+ a ,�',, > °� EDGE OF 1 -2081 A a s ; :': s > o z 0 z a # X 1/2" TEK SCREWS a a - ° z FLOOR SPACED 0 18" O.C. TYP. Z o o W o N w _ o_ EXPANDER 3/8" DIAM. x 3" BEARING B -WA m a u W � <a (1 -2056) LIP WEDGE -BOLT r ---------- - - - - - - -- 1 -2056 o N > a <� 1 -0501, WHEN SPECIFIED I 4 -3/4" (1 -2083) I ,- --- ----- - ----- BY P.E.I. ENGINEERING �________ z J / #10 x 2 -1/2" TEK SCREWS #10 x 2" TEK SCREWS �� EXTERIOR SIDE ®a Q`° LO 0 0 a = I 3" FROM TOP & BOTTOM 3" FROM TOP & BOTTOM ° En W o I & MAX. 19 -1/2" SPACING & MAX. 19 -1/2" SPACING v o �� �w� I ; s PLAN VIEW OF A —B CORNER z A �0 Y I 1 -2022 OR 1 -0201; WHEN 1 w z Z = 6 ON DECK FOUNDATION O� 3 =° SPECIFIED BY P.E.I. ENGINEERING 1 N I HIGH WIND MEETING RAIL I DECK FOUNDATIONS SUPPORTING ENCLOSURES MUST '�' w = Z 00 I REINFORCING REQUIREMENTS 1/8" POP RIVETS AT TOP, f INCLUDE ADEQUATELY SIZED SUPPORT POSTS ON ®z ° \ CONTACT P.E.I. ENGINEERING MIDDLE, & BOTTOM; TYP. / w o `'' 1 -2049 CONCRETE PIER FOOTINGS PROPERLY SIZED AND LOCATED ,.a o w AT ENCLOSURE GANGINGS, CORNERS, RIDGE SUPPORTS, w ^a AND ALL REQUIRED DECK SUPPORTS. DECK LEDGER SEE DETAIL 7C ON SHEET 5 z -206 ( ) f� 1 -2078A CONNECTION TO EXISTING HOUSE MUST PROVIDE FOR CORNER POST a \\ REQUIRED LOAD CAPACITY, OR A CARRIER BEAM MAY BE Q a 1 -2051 \ TO FLOOR EXPANDER (1 -2056) REQUIRED AT THE HOUSE WALL. A MINIMUM OF 4 0 o F a \ i -2016 CONNECTION ON WOOD OR 4- INCHES SPACE BETWEEN BOTTOM OF JOISTS AND TOP W a? 1 -2053 - -- - - --{\ CONCRETE FOUNDATION OF GRADE MUST BE PROVIDED. og w LOCATE 2 -3/4" BACK FROM �� F = o V `� INCLUDE A CONTINUOUS CONCRETE PERIMETER TRENCH N= IP OF FLOOR EXPANDER �� SEE GENERAL NOTES ON SHEET i CONCRETE FOUNDATION SUPPORTING ENCLOSURES MUST a'; o = W a W Lij J (1 - 2056) AS SHOWN ON o,,,", w 1 -2056 FOR REQUIREMENTS FOR PRESSURE w _ = a w �� FOOTING OF ADEQUATE WIDTH AND DEPTH TO PROPERLY ���� a (1) #8 x 1' TEK CONCRETE FOUNDATION, TYP. ��\ TREATED LUMBER AND FASTENERS. SUPPORT IMPOSED LOADS AND PROVIDE PROTECTION FROM < 3 w SCREW ® TOP & I �� FROST HEAVE. d�W W�- 2 - ��o D- m in BOTTOM; 1 /3rd UP (2) #8x1' TEK SCREWS; ,,,� -� „c =6°=� rc 2 z < & 1 /3rd DOWN BOTH SIDES 8- 0026; WHEN SPECIFIEQ �, LOCATIONS OF CUPS WILL VARY FOR WOOD AND y U w # x 1/2" TEK BY P.E.I. ENGINEERING CONCRETE CONNECTIONS. x w SCREWS EACH SIDE „ W m 3/8 DIAM. x 3 WEDGE -BOLTS U/ ATTACHING SUNROOM WALL EXPANDER TO EXISTING STRUCTURE: = _ F_ �' G�' 1 -2062 1 -2061 _= 'c. ., 0 - -3 W v,d WOOD FRAMED STRUCTURES & WOOD FRAMING WITH BRICK VENEER ln/ USE 1/4 -INCH DIAMETER GALVANIZED LAGS & WASHERS PROVIDING A 4 -3 4' 1 -2082 MINIMUM 1 -1/2 -INCH EMBEDMENT INTO WOOD FRAMING OR WOOD / BLOCKING INSTALLED AND NAILED TO WOOD FRAMING AT ALL LOCATIONS I / NOTED BELOW. FOR BLOCK MASONRY, BLOCK WITH BRICK FACING, OR — U) t l 2-3/4 / #8 x 1 2' CONCRETE, USE 1/4-INCH DIAMETER TAPCON LE FASTENERS PROVIDING Q Q �I it % / / TEK SCREWS 1 -3/4 -INCH EMBEDMENT INTO MASONRY OR CONCRETE AT ALL LOCATIONS `� C� TOP & BOTTOM; NOTED BELOW. -'�/ 1 /3rd UP & 1 /3rd BEARING(WALlS: Q z 1-2081A 1 -2078 1 -20098 LOCATE 2) FASTENERS NEAR FLOOR LEVEL (Z) AT KNEEWALL OR RAILING Q 1 -206 1-201 1 -206 1 -206 cn� DOWN HEIGHT, (2) AT TRANSOM, & (2) NEAR HEADER HEIGHT. INSTALL SINGLE W 1 -2082 1 -2016 LO FASTENERS LOCATED AT 16" O.C. VERTICALLY AND STAGGERED ALONG Z C) Q THE EXPANDER HEIGHT BETWEEN DOUBLE FASTENER LOCATIONS TYPICAL. -3/4 "- ASTER FRAME WIDTH ROLLING DOOR WIDTH FOR NONBEARING WALLS: U) (n LOCATE (2) FASTENERS NEAR FLOOR, (2) AT KNEEWALL OR RAILING HEIGHT, w (2) AT TRANSOM HEIGHT, (2) AT H, & (2) NEAR TOP END OF EXPANDER. U) Q & -- PLAN VIEW 0 F B — C C 0 R N E R EXTERIOR SIDE #8 x 1 /2" TEK SCREWS (1) INSTALL SINGLE FASTENERS LOCATED AT 16" O.C. VERTICALLY AND STAGGERED Q NON BEARING C -WALL ® TOP, BOTTOM 1 /3rd UP ALONG THE EXPANDER HEIGHT BETWEEN DOUBLE FASTENER LOCATIONS TYPICAL ON CONCRETE FOUNDATION & 1 /3rd DOWN, BOTH SIDES 60F �� SHEET