Loading...
708 N 16th St CITY or BLNQ April 16,2009 Brian and Marian Fimbres 708 N. 16th Street Blair, NE 68008 RE: N 70' S 140' W 140' Lot 14, block 118, Blair City, Washington County, Nebraska 708 N. 16th Street Dear Mr. and Mrs. Fimbres, We have received a complaint that you have a pool in your back yard but have not completed the fence around it. In checking our records, you have an open building permit for this fence. We also noted that your pool measures at least 48 inches and does not require a barrier. However, the 2006 International Building Code does state that where an above ground pool structure is four foot or higher and used as a barrier and the means of access is a ladder or steps, then the ladder or steps shall be capable of being secured, locked or removed to prevent access. Therefore, please accept this as a courtesy letter encouraging you to either complete the fence prior to filling the pool with water or you can sign an agreement with the City of Blair that you agree to secure, lock or remove the ladder or steps to prevent access to the pool when not in use. If you have any questions or would like to sign the ladder agreement, feel free to contact either Brenda Wheeler or myself at (402) 426-4191. Thank you for your cooperation in this matter. SinC"j!ke ~ Phil Green Assistant City Administrator cc: GeoffHall, City Attorney Brenda Wheeler, City Clerk (5)- EQUALHOUSlNtl 218 South 16th Street. Blair, Nebraska 68008 . 402-426-4191 . Fax 402-426-4195 . E-mail cltyofblair@ci.blair,ne,us "'''''"''' Blair Building Permit Detail Permit #: 13042 Issued: 8/4/2008 Completed: Location: 708 N 16th St Owner: Brian & Marian Fimbres Address: 708 N 16th St Type: Fences - All types Valuation: 300 Blair, NE 68008 Phone: 402 658 0896 Permit Fee: 20 Issue Fee: 20 Deposit Amt.: Receipt #: Section: Subdivision: Township: Range: Lot: Block: 6' high wood privacy fence around swimming pool. Must be at least 10' in from center of alley. Contractors SELF General Contractor Permit # Issued Remarks Inspections Date 8/28/2008 By OEM Final Inspection of Project Pass Date: _ 5'" 2 Y-rj if! ~omplai nt Form Address/Location: "'/ u'f' I '" I .;"1-. rJ,I'- ~1- ,~ J Nature of Complaint:- l< fe r ~ , - Street Light Chuck Hole "\t"1." {Y\ Weeds/Grass Car/Truck Unlicensed or Inoperable Junk -' Sidewalk Comments: = = APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 GENERAL AG 101.1 General. The provisions of this appendix shall con- trol the design and construction of swimming pools, spas and hot tubs installed in or on the lot of a one- or two-family dwell- ing, SECTION AG102 DEFINITIONS AG102.1 General. For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chap- ter 2. ABOVE-GROUND/ON-GROUND POOL. See "Swim- ming pool." BARRIER. A fence, wall, building wall or combination thereof which completely sUlTounds the swimming pool and obstructs access to the swimming pool. HOT TUB. See "Swimming pool." IN-GROUND POOL. See "Swimming pool." RESIDENTIAL. That which is situated on the premises of a detached one- or two-family dwelling or a one-family town- house not more than three stOlies in height. SPA, NONPORTABLE. See "Swinmling pool." SPA, PORTABLE. A nonpermanent structure intended for recreational bathing, in which all controls, water-heating and water-circulating equipment are an integral part of the product. SWIMMING POOL. Any structure intended for swimming or recreational bathing that contahls water over 24 inches (610 mm) deep. This includes in-ground, above-ground and on-ground swimming pools, hot tubs and spas. SWIMl\1ING POOL, INDOOR. A swimming pool which is totally contained within a structure and surrounded on all four sides by the walls of the enclosing structure. SWIMMING POOL, OUTDOOR. Any swimming pool which is not an indoor pool. SECTION AG103 SWIMMING POOLS AG103.1 In-ground pools. In-ground pools shall be designed and constructed in conformance with ANSI/NSPI-5 as listed in Section AGl08. AGI03.2 Above-ground and on-ground pools. Above- ground and on-ground pools shall be designed and constructed in conformance withANSI/NSPI-4 as listed in SectionAG1 08. 2006 INTERNATIONAL RESIDENTIAL CODE@ SECTION AG104 SPAS AND HOT TUBS AG104.l Permanently installed spas and hot tubs. Perma- nently installed spas and hot tubs shall be designed and con- structed in conformance with ANSI/NSPI-3 as listed in Section AGlOS. AG104.2 Portable spas and hot tubs. Portable spas and hot tubs shall be designed and constructed in conformance with ANSI/NSPI-6 as listed in Section AGl08. SECTION AG105 BARRIER REQUIREMENTS AGI05.l Application. The provisions of this chapter shall control the design of barriers for residential swimming pools, spas and hot tubs. These design controls are intended to pro- vide protection against potential drownings and near- drownings by restricting access to swimming pools, spas and hot tubs. AG105.2 Outdoor swimming pool. An outdoor swimming pool, including an in-ground, above-ground or on-ground pool, hot tub or spa shall be sUl1'0unded by a barrier which shall comply with the following: 1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the banier which faces away from the swimming pool. The maxi- mum veliical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade, such as an above-ground pool, the banier may be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the banier is mounted on top of the pool"structure, the maximum vertical clearance between the top of the pool structure and the bottom of the ban'ier shall be 4 inches (102 mm). 2. Openings in the banier shall not allow passage of a 4-inch-diameter (102 mm) sphere, 3. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. 4. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the hori- zontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical mem- bers shall not exceed 13/4 inches (44 mm) in width. Where there are decorative cutouts within vertical mem- bers, spacing within the cutouts shall not exceed 13/4 inches (44 mm) in width. 609 APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 GENERAL AG 101.1 General. The provisions of this appendix shall con- trol the design and construction of swimming pools, spas and hot tubs installed in or on the lot of a one- or two-family dwell- ing. SECTION AG102 DEFINITIONS AG 102.1 General. For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chap- ter 2. ABOYE-GROUND/ON-GROUND POOL. See "Swim- ming pool." BARRIER. A fence, wall, building wall or combination thereof which completely sUlTounds the swimming pool and obstructs access to the swimming pool. HOT TUB. See "Swimming pool." IN-GROUND POOL. See "Swimming pool." RESIDENTIAL. That which is situated on the premises of a detached one- or two-family dwelling or a one-family town- house not more than three stOlies in height. SPA, NONPORTABLE. See "Swimming pool." SPA, PORTABLE. A nonpermanent structure intended for recreational bathing, in which all controls, water-heating and water-circulating equipment are an integral part of the product. SWIMMING POOL. Any stmcture intended for swimming or recreational bathing that contains water over 24 inches (610 mm) deep. This includes in-ground, above-ground and on-ground swimming pools, hot tubs and spas. SWIMMING POOL, INDOOR. A swimming pool which is totally contained within a structure and surrounded on all four sides by the walls of the enclosing structure. SWIMMING POOL, OUTDOOR. Any swimming pool which is not an indoor pool. SECTION AG103 SWIMMING POOLS AG103.l In-ground pools. In-ground pools shall be designed and constructed in conformance with ANSI/NSPI -5 as listed in Section AG 108. AG103.2 Above-ground and on-ground pools. Above- ground and on-ground pools shall be designed and constructed in conformance with ANSI/NSPI-4 as listed in Section AGl 08. 2006 INTERNATIONAL RESIDENTIAL CODE@ SECTION AG104 SPAS AND HOT TUBS AG104.1 Permanently installed spas and hot tubs. Perma- nently installed spas and hot tubs shall be designed and con- structed in conformance with ANSI/NSPI-3 as listed in Section AGl08. AG104.2 Portable spas and hot tubs. Portable spas and hot tubs shall be designed and constructed in confOlmance with ANSI/NSPI-6 as listed in Section AGl08. SECTION AG105 BARRIER REQUIREMENTS AG 105.1 Application. The provisions of this chapter shall control the design of barriers for residential swimming pools, spas and hot tubs. These design controls are intended to pro- vide protection against potential drownings and near- drownings by restricting access to swimming pools, spas and hot tubs. AG 105.2 Outdoor swimming pool. An outdoor swimming pool, including an in-ground, above-ground or on-ground pool, hot tub or spa shall be surrounded by a barrier which shall comply with the following: 1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the banier which faces away from the swimming pool. The maxi- mum veltical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade, such as an above-ground pool, the ban.ier may be at ground level, such as the pool structure, or mounted on top of tlle pool structure. Where the barrier is mounted on top of the pool.structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). 2. Openings in the barrier shall not allow passage of a 4-inch-diameter (102 mm) sphere. 3. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. 4. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the hori- zontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical mem- bers shall not exceed 13/4 inches (44 mm) in width. Where there are decorative cutouts within vertical mem- bers, spacing within the cutouts shall not exceed 13/4 inches (44 mm) in width. 609 tion(s) at least 6 inches (152 mm) and not more than 12 inches (305 mm) below the minimum operational water level or as an attachment to the skimmer(s). SECTION AG107 ABBREVIATIONS AG107.1 General. ANSI-American National Standards Institute 11 West 42nd Street, New York, NY 10036 AS ME-American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 ASTM-ASTM International 100 Barr Harbor.Drive, West ConshohQcken, PA 19428 NSPI-National Spa and Pool Institute 2111 Eisenhower Avenue, Alexandria, VA 22314 I.' UL-Underwriters Laboratories, Inc. 333 Pfingsten Road : Northbrook, Illinois 60062-2096 SECTION AG108 STANDARDS AGI08.1 General. ANSI/NSPI ANSI/NSPI-3-99 Standard for Permanently Installed Residential Spas. . . . . . . . . . . . . . . . . . . AGl04.1 ANSI/NSPI-4-99 Standard for Above-ground/On-ground Residential Swimming Pools . . . . . . . . . . . . AG103.2 ANSI/NSPI-5-99 Standard for Residential In-ground Swimming Pools . . . . . . . . . . . . . . AGI03.1 ANSI/NSPI-6-99 Standard for Residential Portable Spas . . . . . . . . . . . . . . . . AG 104.2 m ANS.I/NSPI-5.-200.3 Standard for Residential g In-ground Swunmmg Pools . . . . . . . . . . . . . AGl03.1 ANSIJASME A112.19.8M-1987 (R1996) Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs and Whirlpool Bathing Appliances . . . . . . . . . . . AGl06.2 ASTM ASTM F 1346-91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and HotTubs . . . . . . . . . . . . . . . . . AG105.2,AG105.5 ASME ASME A112.19.17 Manufacturers Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub and Wading Pool. . . . . . . . . . . . . . . . . . . . . AGl06.3 2006 INTERNATIONAL RESIDENTIAL CODE@ APPENDIX G UL UL2017-2000 Standard for General-purpose I Signaling Devices and Systems-with Revisions through June 2004. . . . . . . . . . . . . . . . . . AGl05.2 611 tion(s) at least 6 inches (152 mm) and not more than 12 inches (305 mm) below the minimum operational water level or as an attachment to the skimmer(s). SECTION AG107 ABBREVIATIONS AG107.1 General. ANSI-American National Standards Institute 11 West 42nd Street, New York, NY 10036 ASME-American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 ASTM-ASTM International 100 Barr Harbor.Drive, West ConshohQcken, PA 19428 NSPI-National Spa and Pool Institute 2111 Eisenhower Avenue, Alexandria, VA 22314 I. UL-Underwriters Laboratories, Inc. 333 Pfingsten Road . Northbrook, Illinois 60062-2096 SECTION AG1 08 STANDARDS AG108.1 General. ANSI/NSPI ANSI/NSPI-3-99 Standard for Permanently Installed Residential Spas. . . . . . . . . . . . . . . . . . . AGl04.1 ANSI/NSPI-4-99 Standard for Above-ground/On-ground ResidentialSwimmingPools . . . . . . . . . . . . AGl03.2 ANSI/NSPI-5-99 Standard for Residential In-ground Swimming Pools . . . . . . . . . . , . . . AGl03.1 ANSI/NSPI-6-99 Standard for Residential PortableSpas . . . . . . . . . . . . . . . . AGl04.2 '..... ANS.I/NSPI-5.-200.3 Standard for Residential D In-ground SWllnmmg Pools . . . . . . . . . . . . . AGl03.1 ANSI/ASME A112.19.8M-1987 (R1996) Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs and Whirlpool Bathing Appliances . . . . . . . . . . . AGl06.2 ASTM ASTM F 1346-91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and HotTubs . . . . . . . . . . . . . . . . . AGl05.2,AGl05.5 ASME ASME A1l2.l9.17 Manufacturers Safety Vacuum Release Systems (SYRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub and Wading Pool. . . . . . . . . . . . . . . . . . . . . AG 106.3 2006 INTERNATIONAL RESIDENTIAL CODE@ APPENDIX G UL UL2017-2000 Standard for General-purpose I Signaling Devices and Systems-with Revisions through June 2004. . . . . . . . . . . . . . . . . . AGl05.2 611 Identify from: - Ownership Parcels Identified 1 feature Tuesday, Mar 24, 2009 10:34 AM Ownership Parcels location: Field OBJECTID _1 Dissolve _Shape Problems ParcelType P arcelID CalcArea OBJECTID PARCEL CURRENT OWN MAIL1 MAIL2 MAIL3 ZIPCODE SITUS LEGAL PRIrv'lAR YSIT Parcelldentity Shape_Length Shape_Area 066 Feet 36032 Polygon Single Owner Parcel 690048510 0.224825 946 890048510 FIMBRES I BRIAN SR & fv'lARIAI\J 708 N 16TH ST BLAIR} I\JE 68008-0000 708 \N 16TH ST BLA BC f\l70'S140'W140'lOT 14 BLK 118 114 PC 15 708 \N 16TH ST BLA 890046510 419.658004 9793.374781 . ii.....,.. '..." '1'1;> ? '. - :lt~d. ' ..... ~'1 ", . :g ,~ .....~.e