Loading...
BP12960 1 R CITY OF BLAIR - APPLICATION FOR BUILDING PERMIT Permit # i l.. q&U Date: L} 12-31 8<i'S, Approximate Completion Date: i-2.. ~i J o~ Site Plan Attached: REScheck Attached: Complete Plans Attached Application for: ResidentialX Commercial/Industrial New Construction Manufactured Home Modular Move-on: Home Accessory Building Other Remodel L - Addition Accessory Bui lCIi rig: Garage ~ Pole Barn_ Other Floor Type: Dirt Concrete Electricity: Yes _ No Other Utilities: Public Water: Yes_ No Private Well If yes, responsible entity: Blair OPPD Line Kennard Agreement-need~d: _ Date Agreement Received:_ Public Sewer: Yes_ No Septic Drawing Provided: _ If yes, responsible entity: Blair _ Kennard_ County Road Permit Required: Yes_ No _ Submitted: Yes _ No _ A<fd;tional Descqption .Of project 'f necessarx.:bc~ rh.CLi\J- Re\rl....... ckJ . updaleol Old 6D cd t beCLIn W W{-' LaC(" O\US cV d ~ d eclY'<:S,S \I \ h..c llu) - Proiect Information: Job Address: \~53 b (c3X\.* 04- Pc cdt- L/ (L) Legal Description (if applicable) Owner: ~blf(~OvY\ lq nl~ \ Contractor: t\\Y\L\\ l~<O-\\'\lL\lO'1 \ Address: f3 roo 1.f5:51<;;/ ~i 11 #.1 t~ft!(.('JL, if!1; &/3 /lJlt13 , (/ 2rcl)'l'l.\!- Phone#~?itJ -lS3(5 Address: Phone #: Cell #: >< ~ -J5acf Separate permits are required for electrical, plumbing, hearting, ventilating and air conditioning, and septic systems. By my signature below, I acknowledge this building permit application does not constitute issuance of this building permit. I further agree that construction covered by this permit application shail not be commenced until) have received a copy of a permit signed by the Building Inspector. ) hereby agree to perform the proposed work in accordance with the specifications set forth above and in accordance with the codes/ordinances of the City of Blair and the State of Nebraska. ) understand that this permit is void if work is not commenced within 180 da or is not completed within two (2) years of date of issue. '2 wnerjContractor x Ai / :z~J(j?s Date I . , f f .~ "-'r i ~~f "1' ~r';J\"i .,. ",," '(tq~ ~-, ZONING REVIEW: ZonimVFlood Plain/Utilities: Current Zoning: fl'riL---- Conditional Use Permit Required: Yes _ No_ Date CUP Approved: State Fire Marshal Required: Yes No Variance Required: Yes _ No_ Minimum Setbacks: Front.;;1JJ.. Second Front Side 17 Side _ Rear.....4;) lot SQuare Footage: length x Width: lot Coverage % ~DrivewavsLSjdftWalks:____.... Sidewalk required: Yes_ No-A- NoXU Sidewalk Waiver: Yes Date Waiver Approved: Flood Plain: Yes__ No If yes, specify special requirements: N/~ BUilDING INSPECTOR REVIEW: Number of Stories One Two Th ree Four >Four High Rise (>75 ft) _. Tvpe of Residential Structure: Ranch _ Two Story _ Split Entry _ Raised Ranch _ Other Rooms _ Bedrooms _ Bathrooms _ Fireplaces _ Gas_ Electric _ Egress in Basement: Required: Yes _ No _ Provided on Plans: Yes No Sleeping Rooms Living Area Other Egress SQuare Footage: Main level: Basement: (Unfinished) Garage: Detached Garage: Addition: Porch: Front Deck that affect setbacks: Second level: Third level (Finished) 2 bay_ 3 bay_ 4 bay_ 5+ bay Pole Barn: Remodel: Side Front Side Rear Rear Occupancy Classification: Assembly, theaters, with stage Assembly, theater, without stage _ Assembly, nightclubs _ Assembly, restaurants, bars, banquet halls _ Assembly, churches _ Assembly, arenas _ Assembly, general, community halls, IibrClries, museums_ Business Educational Factory and industrial, moderate hazard _ Factory and industrial, low hazard _ High Hazard, explosives_ High Hazard HPM Institutional, supervised environment _ Institutional, incapacitated _ Institutional, restrained _ Institutional, day care facilities _ Mercantile Residential, hotels _ Residential, multiple family _ Residential, one- and two-family Residential, care/assisted living facilities Storage, moderate hazard _ Storage, low hazard _ Utility, miscellaneous_ Is buildinli! reauired to be protected bv automatic fire sprinkler svstem?" No Only partially in some areas or rooms Please Specify Yes _ If yes, the standard to which the sprinkler system will be designed: NFPA 13 NFPS 13R NFPA 13D Driveway Grade: (percentage) (Dale will review new residential construction) (AI will review all second access requests and industrial and commercial driveway requests) Required Off Street Parking: Permit Fee Calculation: RESIDENTIAL - NEW CONSTRUCTION: Buildinli! Permit Deposit Fee: Residential additions/remodels/accessory buildings valued under $10,000 $ Fee = $200.00 Commercial, new homes and residential additions/remodels/accessory buildings valued $10,000 or greater $ Fee - $500.00 All other permits valued under $10,000 No Deposit Fee Permit fee is: Finished sqjft area (not including finished basement area) Finished basement sqjft area Unfinished basement sqjft area Garage sqjft area Total Valuation: X $88 X $53 X$26 X$20 $ $ $ $ $ $ $ $ Total Valuation Multiplied by 0.0056 = Issuance Fee: 20.00 Total Permit Fee = DepositjPermit Fee/Issuance Fee RESIDENTIAL - ADDITIONS / REMODELS and COMMERCIAL - NEW CONSTRUCTION / ADDITIONS / REMODELS: Business/I ndustrialjEd ucational/ Assembly/Factory/Storage/Utility *Porches with roofs/screened patios are considered additions Building Permit Deposit Fee: Residential additions/remodels/accessory buildings valued under $10,000 $ Fee = $200.00 Commercial, new homes and residential additions/remodels/accessory buildings valued $10,000 or greater $ nOD. cO Fee - $500.00 All other permits valued under $10,000 No Deposit Fee Construction Valuation will be computed by Sq/ft area X $60 Accessory Buildings & Interior Remodeling Proiects will be computed by Sq/ft area X $40 Permit fee is: Finished sqjft area Finished sqjft area 3'17 X $60 X $40 $ $ 15 I B80 $0 TO $49.............................................................................................. $0 (plus Permit Issuance Fee) $50 TO $9,999............................................................................................$50 $10,000 TO $99,999............................................................................................$50 + $6 per additional $1,000 $100,000 TO $249,999......................................................................................... $590 + $4 per additional $1,000 $250,000 TO $499,999............,..........................................................................$1,190 + $3 per additional $1,000 $500,000 TO $999,999......................................................................................$1,940 + $2 per additional $1,000 $1,000,000 AND OVER ...................................................................................... $2,940 + $1 per additional $1,000 Permit Fee calculated from chart above $ BO.OO of) 20.00 ::: I fJlP' ~ 00 . 00 Issuance Fee: $ $ Total Permit Fee = Deposit/Permit Fee/Issuance Fee Approved bY>-/)c2~~~bate: fL?~ Contingent On Approval by Fire Marshall Meet IBC, IPC, IMC and NEC Code Requirements X Sleeping Rooms below Story and in Basement required to have egress ~ For Office Use Only Date Permit Paid: Permit Fee: Deposit Amount Receipt # Deposit Paid by for return to: Building Inspection Pouch given: Yes _ No ELECTRICAL PERMIT APPLICATION Jurisdiction of City of Blair, Nebraska 218 South 16th Street Blair, Nebraska 68008 Fax (402) 426-4195 (402) 426-4191 Application Date: Lj /23 t o<;s Job Address E 2882 0'0 ~~ Permit Fee: $ 1<6'-- (tULf& Mail Address S(YfrY!e-. Ow,\er ~ '" L 1 VOrGULYl l Vlch ~~~\+ 3. Class of Work: Describe 'X ~rl~\ , 4. \AL\.~\ 5.Current License on File 0 Yes Mail Address 6R-\- ~b.J- LA c o No 0 Service Fee = (Amp Fee + 2.00 per branch circuit) 1-100 Amp Fee.......................$13.00 101-200 Amp Fee.......................$18.00 201-300 Amp Fee...... ...... ...... .. ...$30.00 301-400 Amp Fee......... ... ...... .....$42.00 401-500 Amp Fee...... ... ... ...... .....$55.00 501-600 Amp Fee...... ... ... ...... .. ...$67.00 601-700 Amp Fee... ...... ............ ..$80.00 701-800 Amp Fee...... ............ .. ...$92.00 801-900 Amp Fee.................... .$105.00 901-1000 Amp..................... ...$117.00 IF OVER 1000 Amp 1st 1000 Amp Fee..................$117.00 Each additional 100 Amps.........$13.00 Notice I hereby celiify that I have read and examined this application and know the same to be true and correct. All provisions ofIaws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. 4 ?L-- Zip t8&1~~$ Phone Zip REMODELING/ADDITIONS 0 UPGRADE SERVICE Completion Date ELECTRICAL PERMIT FEES Upgrade Existing Service............ .$10.00 Temporary Service.................... $10.00 Fire Alarm System................. ....$10.00 Signs. .. . . . . . . . . . . . . . . . .. . . .. . . . .. . . . .. .... $15.00 Miscellaneous Apparatus......... .....$11.00 AC/DC Circuit... .................... ....$5.00 Commercial/Multi Family and All Upgrades: # of Circuits x $2.00 Amp Fee Amp Fee + Circuit Total New Residential: (Finished Area) Single/Two Family Dwellings sq.ft.x.045 Modular/Manufactured Homes... ...$50.00 Receptacle/Switch Outlets '1 Fixtq:res \ ~ x $.75 Smoke Detectors x $3.00 Residential/Commercial Appliance # Fixed Outlets x $3.00 Motor(s) x $3.00 Power Apparatus (220 V oIts) # Apparatus x $5.00 0/00 Permit Issuance Fee.................. ..$20.00 01 0 lJO ~W Total Comment: WHEN PROPERL Y VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT I Approved By: K \ {\\J & Ub: CITY OF BLAIR, NEBRASKA Phone 402-426-4191 RECEIVED OF: ADDRESS CITY, STATE, ZIP CODE THANK YOU KEEP THIS COPY FOR YOUR RECORDS. NO RECEIVED BY Pounds Printing, -Elair,,_ NE 68008 /]- y ..- N I~~- I~C-~- r-5' 1- -8'5 u_ 20'5 -I ..13'5 1'-7' '1 [}'/ o[J o ..- N~ .' 2'6 k,-- 1-- - 10'11-- 13'5 - --- L___ 7' ~ ", ~- 20'5- j --.-------;r- y ..- N -~'~'~~=~"":~'~"""':"""""""'-~~~'"",~~,,,~~-,,_.-",:co._.:"."...,~:~..:...,..,......,-...,;.......,.....,.........,,-.,.......=~~,_....,....,... "';".''''''''~,~,~~~'~'7'''''~''''.7''7':''"<:'''''''--'''''''7''''...,......--,~"""",--o-.--'''T'''--",,","7''7' , . , BUILDING INSPECTION REPORT . ./' . [LJ/CITY OF BLAIR D WASHINGTON COUNTY., D OTHER ~7~- I/) i-I LOCATION OF INSPECTION' I O'~:?.) '.0 V arc- ,S'r NAME OF OWNER' "J DY d.ent L LI n U/\ CONTRACTOR,-:?;:f t P DATE INSPECfION REQUESlED- r-i~- (l) 3 TIME INSPECTION REQUESTED- \0', mJl,M PERMIT NO- f 'LX j( z... TYPE OF INSPECTION REQUESTED: D CONFERE~TATUS CHECK ~~;G:- ~D-;~~;;G D DECK FOOTING ~RAMING D DRYWA~;;AL D P~Z ~. --;~~.~~~:; COMMENTS: Y U ~~..,.;..,.......",.,."""""""'.."....,"""'=~= UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE D_p ARTIAL . _____ _ ____ . PASSED FAILED D D COMMENTS: ELJWTRICAL!' ROUGH IN ,~~INAL D PERMANENT SERVICE D D PARTIAL ( SERWCE Q,:lRECONNECT COMMENTS: MECHANICAL:D ROUGH-IN D A/C D FURNACE D RADIANTHEAT D FINAL D PARTIAL PASSED FAILED D D PLUMBING: D GROUNDWORK D ROUGH-IN 0 FINAL D WATERMETERINSTALLED D PARTIAL D PRESSURE TEST FAILED D " OC~:{JPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED _ _ ,./ __ ;_, _ ' NQl'ESIREMARKS 5v'nt'J;::;e: ifm-~J Jill ~1{1(!-lt- filUA (t; '. ty;C-li:-/,ce ( ;rF '6l.55/ALE ,40:0 k# /}])Qj //701'0 AC, s~) :~ tJ'JiJ /1/€ ;11/1/1J F"tLv.e, /lc:L /Ii1ti) teJltJ/3J) tJl.6Mre?f b,:Jc0 " .\ ''i ;f,~ -,-~;iif>~"T " ,-'r;,:: ,.-, :" :. ....... ", ,. ,'..C"" '.... .! : ''',', '.; ~ ~.., .; .,. .--''': ", ......, " . '..'..' .,.,. . _.' .,." : .'~. , > DATE OF INSPECTION MADE: .... .. +.. ", "..' .._.c....... "_ c _. ..', _ _.....". ,'_",' . .":', - '''.~. .' '.' ".: .....c.......,:.'... ..." ,. ",:..... ... ...' -... ... ........ '.> +..... .- .,...... ..,...,...-....... .'" ....,. ........ . ." - -'.. .-..- - . TO CONNECt SERVICE: ON-. - +;"\.;,..:"':.T'......~ <,.c...;,..... ; '"~'.~:." ;'i' ." .. ,;...... , ..~ .....co... '.. 'C ;';::L"""'"",',c'""i:.:L25.;.:5:"'.:ic.'""""';iL'",, r: ... c....- ..;,,'.;~..:iO:,~':..-;2'''''.C=;:::';*''' --''':...............:,..:....... ,..... :...:":.."'..:..."..,..,,.':::.:,....., :..,.,...,.:"..:.:.;--..'., "~ -~ i':'j2: 2hj;,~"~J.:~,f;':r4i~:);;[f'),::~i~,~:,,' ,]~~;:~~:t:~ , , ~-"~;;C ~; LOCATION OF INSPECTION' NAME OF OWNER' citY! j am c..~11 ell ;? -- 09 DATE INSPECTION REQUESTED'C':-- I "'Bifi]jbING'INi~PEeiU~~REp:ORT~~'~====-=C=-='~' , " ",.'.",/',:c. k ,~:~~z,ti'it; , . .' : D W ASHINGTON COUNTY~,~~~iIffiR ~g:5" -5 diffi~ ~;b11 t (SJI ~::: CITY OF BLAIR CONTRACTOR' c.-;;r;'n e.h (!cI)7c.J1IALJ cd:t ~~ TIME INSPECTION REQUESTED' PERMIT NO' /,;? i tfl 0 TYPE OF INSPECTION REQUESTED: D CONFERENCE '~STATUS CHECK - ......,.....;; _.<l.&.- .~..,...,...._.- ~ BUILDING: D FOOTING ~'7JDECKFO,OT~G D F~~ D DR~~ALL ~ FINAL D PART~L , P~ED F~ COMMENTS: ~C2~'J0~7 C A~!::'!!d!~ .-- tJ..J~d-~~~:..!::!:!:::.:. q~~_-=- ~ UTILITIES: D SEWERTAP D SEWER D SEPTIC D WATERTA.P D REMOTE D WATERSERVICE D PARTIAL PASSED FAILED D D COMMENTS: ELECTRICAL: D ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNEGT" D PARTIAL '~'''''.''''''''''!''''''''''''~Q\,"'& _4:f"ml.~~-'W"li'');l~~ COMMENTS: MECHANICAL:D ROUGH-lN D AlC D FURNACE D RADIANTHEAT D FINAL PASSED FAILED D D PARTIAL PASSED FAILED D D COMMENTS:, ~ ..""~"..,.,.,......~- :-../ ..'-'~~~~,.."".,.,.",~~~' ...........~~~,;.go.~~ PLUMBING:D GROUNDWORK D ROUGH-IN D FINAL D WATERMETERINSTALLED D PARTIAL '_, , " D PRESSURE TEST , COMMENTS:"., PASSED ,FAILED D CT. .1 , ~i D OCCUP~C~GRANrED 0 CO~tfIONALOCClJPANCYGR.ANt]!;P. "',., ~....""'" ~-"""'"' r~ , . .~{ '';:':j -:,< .:.., ..-,,~ NOTESIREMA.fu(S"- ~. " '. i" '., ':~ " . :.-i LAhb~S . ~ . -/,~ . ~ -" - ~ . - .:. T" ., :.... - ~ ~.- -, ':-'--':':':' ~ ~ << 7