Loading...
250 E-Mail Correspondence.tifHoward Wolfe From: Howard Wolfe Sent: Monday, April 06, 2015 11:23 AM To: Dirk Daubert Cc: bfausett@cfindustries.com; Howard Wolfe Subject: RE: Inspections Attachments: Dirk Daubert Tightening.pdf; SDG Letter 2-12-15.pdf Dirk: What I am looking for is Final Summary letter from the Special Inspector that indicates that he has inspected the bolts and approves of the installation of them. What you have sent is specifications. Fire Marshal approval and a door landing to code will be also needed to finalize the building. Thank you, Howard Wolfe Building Inspector City of Blair 218 South 16th Street Blair, NE 68008 Office: (402) 426-4191 Direct: (402) 426-6696 Fax: (402) 426-4195 hwolfe@ci.blair.ne.us From: Dirk Daubert [mailto•dirkd daubertconstruction.com] Sent: Monday, April 06, 2015 10:57 AM To: Howard Wolfe Subject: Inspections Howard, Attached are the letters, if there is anything else please contact me. Thanks, Dirk Daubert DAUBERT CONSTRUCTION COMPANY INC. 2180 West Military Avenue - Fremont, Nebraska 68025 Office: 402.721.8223 - Fax: 402.753.3655 -Building on Success Since 1951- 11111,11 H- I ,1 a division of Chief Industries, Inc. 1821 S. North Road P.O. Box 2078 Grand Island, NE 68802-2078 Phone (308) 389-7200 FAX (308) 389-7370 January 28, 2015 Dirk Daubert Daubert Construction Company 2180 W. Military Ave Fremont, NE 68025 RE: B3009983 — CF Industries Dirk, This is to confirm that the main frame bolts on the referenced project were designed to use the "snug tight" method of installing the bolts. The following is cut from the frame cross section — page CS1 from the project's erection drawings. If you need anything else, please don't hesitate to ask. REFERENCENOTA. 1, BOLTING RECC]Iu1ME14DATIONS—ALL HIGH STRENGTH BOLTS ARE X325 WITH HEAVY HEX NUTS AND ARE TO BE INSTALLED USING THE SNUG TIGHT METHOD SPECIFIED IPI'TTHE 'SPECIFICATION FOR STRUCTURAL JOINTS USING ABTA A326 BOLTS', I'U1 USHEn BY RC'SC„ DATED JUNE 30,2004. SNUG TIGHT CONDITION IS ATTAINED WITH A FEIN IMPACTS OF AN impAc-r WRENCH OP THE FULL EFFORT OF AN IRON WORKER USING AN ORDINARY SPUD WRENCH TO ®RING THE RUES INTO FIRM CONTACT. Regards, Dave Bergholz Customer Service Manager Chief Buildings C: Gary Taylor, District Manager -DuI uL uuf atL"'JU1111Jf UUP DATE: February 11,, 2015 e;o ATTN: Mr. Dirk Daubert Daubert Construction Company 2180 West Military Avenue Fremont, Nebraska 68025 R FROM: Jared Wagner S.E. PROJECT: CF Industries Metal Building SUBJECT: Anchorage PAGES: 1 Mr. Daubert This memo is being written in response to your request for an opinion of the capacity of the metal building column anchorage to an existing mat foundation. At this time, our understanding is a new metal building measuring 60'-0" long and 24'-0" wide was constructed on an existing four foot thick mat foundation. The anchorage to the mat foundation utilized (4) 3/4 inch threaded rod anchors with Red Head Epcon A7 anchor adhesive with an embedment of 12 inches at each column. The city of Blair has requested a structural opinion fetter on the capacity of the anchorage. After a review of the Chief Metal building drawings, details sent by you, and the following assumptions: • The anchor bolts are grade 36ksi • The adhesive was used in accordance with the manufacturer's recommended installation instructions • The existing concrete pad has a minimum strength of 3000psi It is SDG's opinion the above indicated anchorage would be adequate to resist the code prescribed loads. Finally, SDG makes no warranties for the connection, metal building or foundation. Our letter is solely limited to our opinion of the ability of the column base anchorage to resist the code prescribed loads. If you have any questions please give me a call. CONFIDENTIALITY NOTICE: The message contained In this communications intended only for the use of the individual or entity to which It is addressed, and may contain Information that is privileged and confidential. If you are neither the intended recipient nor the employee or the agent responsible for delivering this message to the intended recipient, you: are hereby notified that any disclosure, copying, distribution or the taking of any action in relevance to the contents of this communication or the message contained in this communication is strictly prohibited If you have received this communication in error, please notify us Immediately by telephone or facsimile, and return the entire communication to us by the address shown. Thank you. the grainger building 105 n. 8th street, suite 100a lincoln, nebraska 66508 p. 402 438 7788 f. 402 43B 7790 www,sdgstructural.com Howard Wolfe From: Howard Wolfe Sent: Friday, April 10, 2015 3:17 PM To: Dirk Daubert Cc: bfausett@cfindustries.com; Howard Wolfe Subject: RE: Inspections Attachments: 250_0001.pdf; 250_0002.pdf Dirk: I received your copy of Architectural Innovations Special Inspections for the anchor bolts. I also need a report for the high strength (A325) bolts for the steel building framing. Attached is the letter from the Architect. Thank you, Howard Wolfe Building Inspector City of Blair 218 South 16th Street Blair, NE 68008 Office: (402) 426-4191 Direct: (402) 426-6696 Fax: (402) 426-4195 hwolfe@ci.blair.ne.us From: Howard Wolfe Sent: Monday, April 06, 2015 11:23 AM To: 'Dirk Daubert' Cc: 'bfausett@cfindustries.com'; Howard Wolfe Subject: RE: Inspections Dirk: What I am looking for is Final Summary letter from the Special Inspector that indicates that he has inspected the bolts and approves of the installation of them. What you have sent is specifications. Fire Marshal approval and a door landing to code will be also needed to finalize the building. Thank you, Howard Wolfe Building Inspector City of Blair 218 South 16th Street Blair, NE 68008 Office: (402) 426-4191 Direct: (402) 426-6696 Fax: (402) 426-4195 hwolfe@ci.blair.ne.us From: Dirk Daubert[ma IIto: dirkdC-adaubertconstruction.com] Sent: Monday, April 06, 2015 10:57 AM To: Howard Wolfe Subject: Inspections Howard, Attached are the letters, if there is anything else please contact me. Thanks, Dirk Daubert DAUBERT CONSTRUCTION COMPANY INC. 2180 West Military Avenue - Fremont, Nebraska 68025 Office: 402.721.8223 - Fax: 402.753.3655 -Building on Success Since 1951- 0 _Arch,tectural Innovations April 08, 2015 Attn: Dirk Daubert Daubert Construction Company 2180 West Military Avenue Fremont, NE 68025 RE: Special inspection of anchor bolts installed in hardened concrete CF industries Metal Building Blair, Nebraska We have completed the final inspections required by IBC 2009 Table 1704.4 Required Verification and Inspection of Concrete Construction, Item W Inspection of anchors installed in hardened concrete. Our inspections have found that the installation of the anchors comply with the approved construction documents and additional specifications provided by Structural Design Group. We did not find any work to be non-compliant therefore no remediation is required. Sincerely, ]eramie J. Nelson, AIA 620 N 48th Street • Suite 102 • Lincoln, NE 68504 • (402) 467-4328 • Fax (402) 421-7713 Email: jnelson@ailincoln.com - Visit us online at www.AlLinealn.com Z abed gg9££qLZ017 uo.prutsuo3 ljagnea WdK£0 960Z 80 udy DAUBERT CONSTRUCTION COMPANY . 2160 West Military Ave. - Fremont, Nebraska 68025 - 402-721-8223 www.daubertconstruction ,corn Building o_n Success Since 1951 Number of Pages: 2 including the cover page Fax To: Howard Wolfe Phone Number: 402-426-6696 Fax Number: 402-426-4191 From: Dirk Daubert Daubert Construction Phone Number: 402-721-8223 Fax Number: 402-753-3655 Remarks: 1 Sine(! 19 S t {—aFed 55g€E5LZ0,v ugpru}suoD ljagnea Wd8E:E0 5602 80 AV Howard Wolfe From: Howard Wolfe Sent: Tuesday, January 19, 2016 12:48 PM To: deb.mitchell@nebraska.gov Cc: Howard Wolfe Subject: Final Inspection Approvals -2 Attachments: 250_0001.pdf Deb: Would you please E -Mail me a copy of the State Fire Marshal final inspection approval for the attached State Code Review? Allan Viox was the Inspector. Thank you, Howard Wolfe Building Inspector City of Blair 218 South 16th Street Blair, NE 68008 Office: (402) 426-4191 Direct: (402) 426-6696 Fax: (402) 426-4195 hwolfe@ci.blair.ne.us 1