BP12811
Permit #: 12811 Issued:
Completed:
Location: 2857 Ravae Ln
Owner: Urban Homes
Address: 2500 W Highridge Cir
Lincoln, NE 68522
Phone: 7704730
Section:
Township:
Subdivision: SOUTHRDG
Blair Building Permit Detail
9/1/2007
8/19/2009
Type: Residential - New Construction
Valuation: 139560
Permit Fee:
Issue Fee:
Deposit Amt.:
Receipt #:
781.54
20
500
20686
Range:
Lot: 29
Block:
1140 SF Ranch style, 3 bedrooms, 2 bath, unfinished walk out, rough in, attached 2 car garage. Deck off of NE side.
TFA: 2760
Contractors
Urban Homes, LLC
BNL Plumbing
BNL Plumbing
Brian Hester Htg. & Air Inc.
CNJ Plumbing Inc
Wolfe Electric
Remarks
7/15/2008
OEM
3/17/2009
OEM
4/28/2009
KAR
4/28/2009
KAR
4/28/2009
KAR
4/28/2009
KAR
4/28/2009
KAR
General Contractor
Plumbing Subcontractor
Plumbing Subcontractor
Heating Subcontractor
Plumbing Subcontractor
Electrical Subcontractor
Permit #
P1823
T1274
M1655
P1762
E2750
Issued
5/27/2008
5/27/2008
7/15/2008
11/15/2007
9/5/2007
Mechanical not complete. No service until house secured.
No address on house. Not complete.
Address is required to be posted on house in a visible location from road. Did not use ACQ
approved fastners on deck joist hangers on side toe nails and missing A joist hanger on north
side joist for landing for stairs and did not toe nail the one joist
hanger. Could not get screen slider on sliding door to deck to shut. GFCI outlet main bath room.
shows no power even though it trips and resets. thre area under stairs can be used for
storage so the area has to have 1/2 inch drywall mud and taped.
Pipe relief valve on water heater to within 6" of floor. Cold air return basement chase has
sharp edges for som one to injure them selfs on. Be more specific when labeling panel which
bedroom is one an which is 2. Not all seams are sealed on furnace.
Neutral wires one per lug cannot be doubled. Bond grounding and neutral bar to can as per
code. SW. bedroom wall line from closet door to entry door is over 2' code requires on outlet
there. Ends of hand rail is to return to wall or end in a newell post.
No Occupancy granted at this time.
Blair Building Permit Detail
4/30/2009
KAR
has to use ACQ approved fasteners on joist hangers where toe nailed and install a joist
hangar north joist on landing. Screen slider on sliding door to deck still wont shut. Ends of
handrails shall return to walls or end in new post. Area under stairs
4/30/2009
KAR
able to be used for storage shall be drywalled and seams mud & taped or seal off so it cannot
be used for storage. Verify with res check form for seal joints seams ductwork basement
walls insulation. $30.00 Reinspection fee due for failing 2nd inspection
7/13/2009
HOW
1.Kriss to inspect panel box.
2. return handarails on stairs.
3. Contractor to provide signed note insulation was installed in basement.
4. Plumbing and mech. finals-passed.
8/20/2009 HOW 1. handrails-final-ok-hw.
Inspections Date By
9/10/2007 OEM Electrical Temporary Service Pass
9/24/2007 OEM Footings Pass
11/15/2007 OEM Plumbing Groundwork Pass
11/15/2007 OEM Plumbing Pressure Test Pass
2/5/2008 OEM Status check Pass
6/19/2008 OEM Sewer Lines Pass Partial
6/20/2008 OEM Footings Pass
6/25/2008 OEM Water Tap Pass
6/26/2008 OEM Sewer Lines Pass
7/9/2008 OEM Plumbing Groundwork Pass
7/9/2008 OEM Plumbing Rough-ins Pass
7/9/2008 OEM Plumbing Pressure Test Pass
7/11/2008 OEM Roof, Drains Fail
7/15/2008 OEM Framing Fail
7/15/2008 OEM Electrical Rough-ins Fail
7/15/2008 OEM Mechanical Rough-ins Fail
7/15/2008 OEM Plumbing Rough-ins Fail
7/16/2008 OEM Mechanical Rough-ins Pass
7/16/2008 OEM Framing Pass
7/16/2008 OEM Plumbing Rough-ins Pass
7/16/2008 OEM Electrical Rough-ins Pass
7/21/2008 OEM Drywall Pass
9/11/2008 OEM Electrical Permanent Service Pass
9/12/2008 OEM Electrical Permanent Service Pass
12/30/2008 OEM Status check Fail
1/12/2009 OEM Conference Fail
3/16/2009 OEM Status check Fail
3/27/2009 SAJ Stop Box Card Pass
4/28/2009 KAR Electrical Final Fail
4/28/2009 KAR Mechanical Final Fail
4/28/2009 KAR Final Inspection of Project Fail
Blair Building Permit Detail
4/28/2009 KAR Plumbing Final Fail
4/30/2009 KAR Final Inspection of Project Fail
4/30/2009 KAR Electrical Final Pass
4/30/2009 KAR Mechanical Final Fail
4/30/2009 KAR Plumbing Final Pass
7/13/2009 HOW Final Inspection of Project Fail
7/13/2009 HOW Mechanical Final Pass
7/13/2009 HOW Plumbing Final Pass
8/19/2009 HOW Final Inspection of Project Pass
CITY OF BLAIR - APPLICATION FOR BUILDING PERMIT
Permit :#
?~/~"U7
Site Plan Attached: ~
Complete Plans Attached
1)9" 'I
J 0 ~ S I -d7
~
Date:
Approximate Completion Date:
REScheck Attached:
/
Aoolication for: ResidentiaJ..: Commercial/Industrial
New Construction ~ - Manufactured Home _ Modular_
Move-on: Home _ Accessory Building Other
Remodel Addition
Accessory Building: Garage _ Pole Barn_ Other
Floor Type: Dirt Concrete Electricity: Yes_
No
Other
Utilities: Public Water: Yes /" No pri~ell
If yes, responsible entity: Blair OPPD Line Kennard
Agreement ne~ _ Date Agreement Received: _
Public Sewer: Yes_ No S~ Drawing Provided: _
If yes, responsible entity: Blair _ Kennard_
County Road Permit Required: Yes_ No _ Submitted: Yes _ No _
Additi,!na! Descr!pt!oy rl project If necesi'ary" llll ~ Y!i. f2 4-<[ ~ ' > iJ<<~ .;l..IJ.zJ:2.
~ ~ I ~"'1- <01 (g) AJ;C;' '.<1 a Ci0- ~. /keL
a_~r;~
Proiect Information:
Job Address:
:lr5l
R ltl\Jt'ul..
'_of 2 cl
Legal Description (if applicable)
Owner: LLJ.,c- t~
Address:
I/~
50 lA ff'-LA'U'\ ~ d 0 e_
Phone#: 77 ()-Ll73 o~
fV ~tA....
Contractor:
Phone :#:
Address:
~
G, t' 5'J-,)
Separate permits are required for electrical, plumbing, hearting, ventilating and air conditioning, and septic systems. By my signature
below, I acknowledge this building permit application does not constitute issuance of this building permit. I further agree that
construction covered by this permit application shall not be commenced until I have received a copy of a permit signed by the Building
Inspector., I hereby agree to perform the proposed work in accordance with the specifications set forth above and in accordance with the
codes/ordinances of the City of Blair and the State of Nebraska. I understand that this permit is void if work is not commenced within
180 day~~ot compl ted within two ) years of date of issue.
~~ ;//!, /D7
d s,'O.)
l\~;a,;: "-
Lu~ I~y-'~(; dvt
Cell :#:
Signature of Owner/Contr etar
n i-",b O-illwVl1c.S tLAo+-(YIt~ /. tAl m
Date
fC((he l-4)ti<-
ZONING REVIEW:
ZonimVFlood Plain/Utilities:
Current Zoning: ~ .M Conditional Use Permit Required: Yes _ No )(
Date CUP Approved:
State Fire Marshal Required: Yes _ No ~ Variance Required: Yes _ No X-
Minimum Setbacks: Front ~ Second Front Side 'I Side _ Rear 2S~
lot Sauare Footat:!e:
length x Width: K170.ls1.ft lot Coverage %
Driveways/Sidewalks: V
Sidewalk required: Yes-A No_
Flood Plain: Yes No X
If yes, specify special requirements:
Sidewalk Waiver: Yes
Date Waiver Approved:
No
BUilDING INSPECTOR REVIEW:
Number of Stories
One V" Two
Three
Four
>Four
High Rise (>75 ft)_
Type of Residential Structure:
Ranch V' Two Story _ Split Entry _ Raised Ranch ----.,;.... Other
Rooms B- Bedrooms ....s..- Bathrooms c:L Fireplaces _ Gas_ Electric _
Egress in Basement: Required: Yes ~ No _ Provided on Plans: Yes /' No_
Sleeping Rooms "".-- Living Area -- Other Egress ---
Sauare Footat:!e: " //"1
Main level: //q-v
Basement: (Unfinished)
Garage: '/80
Detached Garage:
Addition:
Porch: Front Rear
Deck that affect setbacks: Rear
Second level:
/ I ~O (Finished)
2 bay_ 3 bay_ 4 bay_ 5+ bay
Pole Barn:
Remodel:
Side
Front
Third level
/cP I /~ '
Side
Occupancy Classification:
Assembly, theaters, with stage Assembly, theater, without stage _
Assembly, nightclubs _ Assembly, restaurants, bars, banquet halls_
Assembly, churches _ Assembly, arenas _
Assembly, g~meral"community halls, IibrC!ries, museums _
Business" Educational Factory and industrial, moderate hazard _
Factory and industrial, low hazard _ High Hazard, explosives _
High Hazard HPM Institutional, supervised environment _
Institutional, incapacitated _ Institutional, restrained _
Institutional, day care facilities _ Mercantile Residential, hotels_
Residential, multiple family _ Residential, one- and two-family
Residential, care/assisted living facilities
Storage, moderate hazard _ Storage, low hazard _ Utility, miscellaneous_
Is buildinJ:! reauired to be protected bv automatic fire sprinkler svstem?"
No
Only partially in some areas or rooms Please Specify
Yes _ If yes, the standard to which the sprinkler system will be designed:
NFPA 13 NFPS 13R NFPA 13D
Driveway Grade: (percentage) (Dale will review new residential construction) (AI
will review all second access requests and industrial and commercial driveway requests)
Required Off Street Parking:
Permit Fee Calculation:
RESIDENTIAL - NEW CONSTRUCTION:
BuildinJ:! Permit Deposit Fee:
Residential additions/remodels/accessory buildings valued under $10,000 $
Fee = $200.00
Commercial, new homes and residential
additions/remodels/accessory buildings valued $10,000 or greater $
Fee - $500.00
All other permits valued under $10,000 No Deposit Fee
Permit fee is: _
Finished sqjft area //40
(not including finished basement area)
Finished basement sqjft area
Unfinished basement sqjft area / 1'10
Garage sqjft area .tf.80
Total Valuation:
X$88
X $53
X$26
X$20
/00, JZO . 00
$
,
$
$ 2Q, ldt.fO . 01)
$
$ q I lo DO. a ell
$ 781.5'+
$ 20.00
$ 80'. 5*
) ~(:if151.0, ~()
Total Valuation .:..J, . IJI. Multiplied by 0.0056 =
Issuance Fee:
Total Permit Fee = Deposit/Permit Fee/Issuance Fee
RESIDENTIAL - ADDITIONS / REMODELS and
COMMERCIAL - NEW CONSTRUCTION / ADDITIONS / REMODELS:
Business/I ndustrialjEd ucationalj Assembly/Factory/Storage/Util ity
*Porches with roofs/screened patios are considered additions
Buildinl'! Permit Deposit Fee:
Residential additions/remodels/accessory buildings valued under $10,000 $
Fee = $200.00
Commercial, new homes and residential
additions/remodels/accessory buildings valued $10,000 or greater $ 5'00.0 ()
Fee - $500.00
All other permits valued under $10,000 No Deposit Fee
Construction Valuation will be computed bv SQ/ft area X $60
Accessory BuiIdinf!s & Interior RemodeIinf! Proiects will be computed bv Sq/ft
area X $40
Permit fee is:
Finished sqjft area
Finished sqjft area
IlsIO
X $60
X $40
$
$
$0 TO $49.............................................................................................. $0 (plus Permit Issuance Fee)
$50 TO $9,999............................................................................................$50
$10,000 TO $99,999............................................................................................$50 + $6 per additional $1,000
$100,000 TO $249,999......................................................................................... $590 + $4 per additional $1,000
$250,000 TO $499,999...................................................................................... $1,190 + $3 per additional $1,000
$500,000 TO $999,999...........:..........................................................................$1,940 + $2 per additional $1,000
$1,000,000 AND OVER ...................................................................................... $2,940 + $1 per additional $1,000
Permit Fee calculated from chart above
$
Issuance Fee:
$
20.00
Total Permit Fee = DepositjPermit Fee/Issuance Fee
$
Additional Comments:
Approved~ /~,,>>d&-~2 ~#J3/o '7
Contingent On Approval by Fire Marshall
Meet IBC, IPC, IMC and NEC Code Requirements ,J(
Sleeping Rooms below Story and in Basement required to have egress ~)(
For Office Use Only
Date Permit Paid:
Permit Fee: B01.5t.f
Deposit Amount 500. 6D
Receipt #
Deposit Paid by for return to:
Building Inspection Pouch given: Yes _ No
r
"
rIfflED '-
MECHANICAL PERMIT APPLftlttoN
I? 8il
v
M 1655
Jurisdiction of City of Blair, Nebraska
218 South 16th Street
Blair, Nebraska 68008
Fax (402) 426-4195
(402) 426-4191
Application Date:
'11 \5to~
rlT d<J
Permit Fee: $ J-
OF1te:rb'
1.\A.f , C}(\
KCCVCk,e., UltU-
Phone
Job Address
Central AlC d is
Furnace ',Ot Coo
# of Units
Tons
BTU!H
AlC
Furnace
Completion Date:
Comments:
Notice
I hereby certify that I have read and examined this
application and know the same to be true and correct. All
provisions oflaws and ordinances governing this type of
work will be complied with whether specified herein or
not. The granting of a permit does not presume to give
authority to violate or cancel the provisions of any other
state or local law regulating construction or the
performance of construction.
~~dT
I Signature of Contractor or Authorized Agent
,I
:1
(c)
;
7- )~';J&e>r
Date
Zip
:'1\ Zip
I ~'Sf L/t 1'1 ('U 1"1
o Addition 0 Alteration
Phone
LIlt.. 20Q 1
o Replacement
A)e..
o Repair
III tV A O/'ll/
MECHANICAL PERMIT FEES
Forced Air/Heat Pump Systems - Per Unit :;; 6,0-.)
Commercial/Residential (New)...................................... ...$25.00
Air-Conditioner Unit - Per Unit \D. 00
CommerciallResidential (New).................................... ......$10.00
Forced Air Systems/Air Conditioner
Unit Replacement Per Unit CommerciallResidential............... ..$10.00
Refrigeration Units/CoolerslLines/Compressor -
Per Unit Commercial (New or Replacement)........................ ..$10.00
'\
Appliance V ent/Fans. . . . .. . . . .. . . .. . .. . .(Jl~~~
Boiler....................................... ..$15.00
Duct System...............................(~ ~
Gas/Air Outlets....................... x $2.00
/0,00
L..--
iU.<D
.,..----..
Radiant Heat Systems/Gas/Water
Piping System............................. ..$25.00
--~
--
Modular Home........................... ...$50.00
Permit Issuance Fee............... ... ... ...$20.00
Total
c9.0, ~LJ
15. ()0,
Current License on File ~~-Yes" 0 No
o NjA
Comment:
WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
I Approved By: l/ ) ,,';.\ 'd
1) l.-(j{j J1J2. "'1......
~
PLUMBING PERMIT APPLICATION
Jurisdiction of City of Blair, Nebraska
218 South 16th Street
Blair, Nebraska 68008
Fax (402) 426-4195
(402) 426-4191
Application Date:
S- .)7-09
Job Address
:;"f S7
Mail Address
ESIDENTIAL
/h.j.A..}-
Comments:
Notice
I hereby certify that I have read and examined this
application and know the same to be true and correct. All
provisions oflaws and ordinances governing this type of
work will be complied with whether specified herein or
not. The granting of a permit does not presume to give
authority to violate or cancel the provisions of any other
state or local law regulating construction or the
performance of construction.
Signature of Contractor or Authorized Agent
Date
Permit Fee: $
(2 Q./u~.e ~.......
Zip
L~
o Addition 0 Alteration
).-10 \ \
P 1823
){ ),u:;
Phone
lot .f J I Ph?:; () - Ot7 S-
O Repair 0 Replacement
PLUMBING PERMIT FEES
Modular Home... ... ... ... ... ... ....$50.00
Type of Fixture No.
Kitchen... ... ...... ... ... ... ... ... ...$8.00 x I
Bath................................ ..$8.00 x ,")..
Rough-In Bath.................... ..$4.00 x ~
Additional Sinks.................. ..$3.00 x
Laundry/Drain.................... ..$5.00 x
Water Heater..................... ...$3.00 x ~
Outside Water Faucet..................$3.00 x ~
Drinking Fountain.......................$3.00 x
Backflow/Grease Trap...... ...... $1 0.00
Water Service......... ... ...... .. ..$10.00
Sewer............................. ...$10.00
Groundwork..................... ...$10.00
Septic Tank & Laterals........... $10.00
Lawn Sprinkler System......... ...$10.00
Sprinkler System (Commercial). $30.00
Gas/Water Piping System
(Commercial)... ...... ... ........ ...$30.00
Permit Issuance Fee............. ...$20.00
Current License on File
Comment:
Total
o Yes 0 No 0 NjA
WHEN PROPERL Y VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
I Approved By: 9 ({) I
d5 T J r ...vv~
<?JvJ
)tp.0)
'y..LP
),J)
'/") , J)
l:,. 00
I Cr V\;J
/O..W
9j:
PLUMBING PERMIT APPLICATION
Jurisdiction of City of Blair, Nebraska '\ dB II
218 South 16th Street
Blair, Nebraska 68008
Fax (402) 426-4195 T 1274
(402) 426-4191
Application Date:
:;; -J7-o~
00
Permit Fee: $ /r;o ---
OWl}eJ . I i I
1. WWv.+- rn~
Contrl!Rtor0' po. J
2. 1::,1 l, ~
3. Class of Work:
Describe Work:
4.
d-fS 7
Mail Address
Zip Phone
Job Address
Mail Address
Zip Phone
Comments:
o Addition 0 Alteration 0 Repair 0 Replacement
PLUMBING PERMIT FEES
Water Tap Fee - %"
$150.00 ~
Water Tap Fee - 1"
$200.00
Notice
I hereby certify that I have read and examined this
application and know the same to be true and correct. All
provisions oflaws and ordinances governing this type of
work will be complied with whether specified herein or
not. The granting of a permit does not presume to give
authority to violate or cancel the provisions of any other
state or local law regulating construction or the
performance of construction.
Water Tap Fee - 1~" $250.00
Water Tap Fee - 2"
$300.00
SIgnature of Contractor or Authorized Agent
vV
Current License on File
Comment:
Total
o Yes 0 No 0 NjA
WHEN PROPERL Y VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
I Approved By: .~ ' /?-t r JbuJRP-
~
a ~
-< ::r::
8..~
b:J""d
'-< :::0
o
""d
trJ
:::0
r:
>-<
<
>-
r:
---
t:J
>-
>-l
trJ
t:J
~', ~
~~ ~
fl
::r::
---
\/l
~
i~
I
~
~
n n ""1::1 ........0
0 s:: C1l C/J
3 ~ g. npo "0
o <JJ .....
3 C1l 3 --- S'
::: 3 ::E
C1l ..... "
::: ......
;; l' <JJ C1l po cr
n' <JJ ri (D .....
s::
C1l po -...... C/J
::: ::: 2:.""1::1 '-<
<JJ a '--' _. <JJ
C1l C1l . "0 en
0 'Tj S' 3
::: C1l (JQ
3! ~ C/J ........
'-< n
cr <JJ 0
en ~
3
C1l
.....
a
EO'
Vl ':-'
"" ""
N w ""
~ ~ w
0 0 0 ~
0 0 0
:z 0
0
--3
0 0
-
:z a
'"
)>
'J
~
,
~ I)
~ \::
---
\/l
>-<
o
C
:::0
""d
trJ
~
---
>-l
~::1~"g~
s-saoo-o
;a. ~. ~~. ~ ;:
ll> _.....,.... -. ll> (1)
(t --< ~ ~ g g. ri
Qo~;:~;~
~ g g. ~ ~ ~ s- g
""1 ~ _:::::-. 0 ~ ::4.
'='> - ll> ;:l 3 -<: 8-'
s; 5l (too '0 <JJ 0 Q>
~<Q8..~~~g.
=,rin~c...o..s=-a
gao g;"O:; Q ~-~
Sn ~ :::;..o..cn:::r' L..,
8, ::;. !!. 3 ;:l" S' ll> ll> 0
'" _. _..... ll> 3 ~ -
g ~ g- ~ ~ ~ ~ ""1 r;-
v:ln"OO!lt1logttl
::to""1~::rcncr"o..
~~~;:s~~~P-'
g. 2" ~: ;? ~ ~ 2 g,
? a. g ] 8. 2. ~ ~
:5 ~ ~ ~Jg g, 3
o ...., 3 0.. - '" -.
-t~t1l::r2:Q~
9-'-<: r-t- t1l en ""1 0.-
(1) 0 ~ ~. q g 5'-
:r- <:" ::i -g :-+ Vi"
~(1)S;8,;J>
r C/J 0 C/J ::E
po C1l o:l t:I
::;; ~ ..... C1l po 0 ::E l' ;J>
0 ::;; a ..... ;:>::l o:l
::: s:: a ~ S. po C-
n' C1l C1l " po s:: 0- 0 po
C/J ::: :-' ..... ::!l <JJ en ::: ~ s:: ..... .....
...., 0- 0: (JQ ?" a
"0 ::;; C/J 0 S' ..... 0- =:r'
..... po C1l ~ C1l ::r:: ~ o' =:r' C1l
S' ::: 0 (JQ I
..... ::E ::: ...... p
" ..... -< C1l ---
" ?' 0 'Tj a t:I 2:. :::
cr Ro n' ..... 0 po ..... o:l
~ C1l s:: ..... C1l po C/J
..... C1l :-' po
r po ::: ..... S' S'
C/J po <JJ ..... 'Tj ~
'-< en C1l po "
<JJ ...., p' po ~
..... ..... s::
C1l po ..... a
? Vi" po ~
"0
"" "" "" "" ""
- - - "" "" ~
~ ~ ~ ""
~ 0 ~ w w w "" "" "" "" ""
0 0 0 VI w :I"-
0 0 0 0 0 0 0 '=' 0 ?O 00
0 0 0 0 0
0 0 0 0 0 0 0
>< >< >< 0 0 0 0
r- ><
r >< >< >< ><
~ t- M~
~
<:::> ~
\) \J 10 \) <0 <::::J
<0 <0
'0 ~ \) I\J \)
~
o
0-
s::
5l
.....
n
o
3
3
C1l
8-
~
::r::
o
--3 3
'-< C1l
"0
tl>
o
-.
""l
~.
C
""l
tl>
"'e
t"'
~~D
~\'. ~
Z C\ ~
"" ~ ~ g:
VI "'e ::J
~M
g~
z .....
~ ~
~
M
M
\/l
N
-0'
o
;;0
C1l
'0
~.
o
;;0
C1l
'0
OJ
n
C1l
3
C1l
~
:s
o
;:l
<1l
:s
o
:l
<1l
~
~
Lj
~
,-,CO
C~
E;;' ~
0...
"Tj ~ N a: C1
~ ~ ~::;. ;;;; g ~
[3~Z~s, ~
,--,a(1)cr-.~
-+:>.No"'.-+\.l
N '--'..., ::T......
O\-+:>.el--<"
I N :;>;"0\0
-+:>. 0\ ~ :::.>-+,
-' ~ ~
\O::O\\/l~ .......J
-\Ooo::t ~ ~
VIa (1) ......
a(1)~"" ~
oo'-+Z"""'-
g.~
C5~
~~
~
(j
>
~
~
o
-~
'W
'-~
'-<
o
<::r
;J>
0..
~
~
;J>
"0
"0
n'
a
o'
:::
t:I
a
~
I
~
~
""C
""""'
-....l
0\
N
.........
0\
""1::1
C1l
~.
.....
'Tj
C1l
~
""
~
ELECTRICAL PERMIT APPLICATION
Jurisdiction of City of Blair, Nebraska
218 South 16th Street
Blair, Nebraska 68008
Fax (402) 426-4195
(402) 426-4191
Application Date: q I ~ t VI
Job Address
d~Sl
E2750
":! D'
;:)' '\ .
Permit Fee: $ ~l, <? ~
K Cl;\J~
Or~e~1 ~,' L\ ;'< Mail Address
l~rY.Ja,Y"\ ~~
~~t~'c. Up cAr;MLAdd5~H l
3. Class of Work: NEW RESIDENTIAL 0
Describe ;~r : ~ h
4. 0 lOr New ' OO~
5.Current License on File 0 Yes 0 No 0 NjA
Service Fee = (Amp Fee + 2.00 per branch circuit)
1-100 Amp Fee..................... ..$13.00
101-200 Amp Fee..................... ..$18.00
201-300 Amp Fee... ...... ... ...........$30.00
301-400 Amp Fee.......................$42.00
401-500 Amp Fee... ... ... ... ...... .....$55.00
501-600 Amp Fee... ... ... ... ... ... .....$67.00
601-700 Amp Fee... ... ... ... ...... .....$80.00
701-800 Amp Fee... ...... ... ...........$92.00
801-900 Amp Fee.................. ...$105.00
901-1000 Amp...................... ..$117.00
IF OVER 1000 Amp
151 1000 Amp Fee............... ...$117.00
Each additional 100 Amps..... ....$13 .00
Notice
I hereby certify that I have read and examined this
application and know the same to be true and correct. All
provisions oflaws and ordinances governing this type of
work will be complied with whether specified herein or
not. The granting of a permit does not presume to give
authority to violate or cancel the provisions of any other
state or local law regulating construction or the
performance of construction.
~ fltJ cW r!
Date
Completion Date
ELECTRICAL PERMIT FEES
Upgrade Existing Service............ .$1 0.00
Temporary Service.................... $10.00
Fire Alarm System............ ..... ....$10.00
Signs. .. ... . . . . . . . . . . . . . . . . . . . .. . . . . . .. ....$15 .00
Miscellaneous Apparatus......... .....$11.00
ACmC Circuit........................ ...$5.00
CommerciaIlMulti Family and All Upgrades:
# of Circuits x $2.00
Amp Fee
Amp Fee + Circuit Total
New Residential: (Finished Area)
Single/Two Family Dwellings
\ \~O
.. / \ sq. ft. x .045
Modular/Manufactured Homes... ...$50.00
Receptacle/Switch Outlets
Fixtures x $.75
Smoke Detectors x $3.00
Residential/Commercial Appliance
# Fixed Outlets x $3.00
Motor(s) x $3.00
Power Apparatus (220 Volts)
# Apparatus x $5.00
{a,CiD
L30
Permit Issuance Fee.................. ..$20.00
Total
,9/J (
5l ).
Comment:
WHEN PROPERL Y VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
I Approved By: i) L"\'
n DUe ht>(
From:WOLFE ELECTRIC CO.
1 402 731 1226
09/12/2007 05:52 #628 P.001/002
r:;f-P. II. ,UUI
Ij-: LU nVI
l,.'!IY Vi bLAH \4UL, 'fLb.'fI~IJ
NO. j IL~
r. L
ELECTRICAL PERMIT APPLICATION
JUlisdiction of City otBlai:1:. Nebraska
218 South 16 Stt'iet
Blair, Nebraska 68008
Fax (402) 426-4195
(402) 426-4191 .
AppliClItion Daw: or, l.~ I. 0"1
E 2750
. 3D
PetmH Fee: $~' ~ ~
SQb Adil~,
Servlcli' Fee = (Amp F.,., T 2,00 pel' branch ~i1'cuit)
1.100 Amp Fe........................$13.00
101.200 Amp Pn......... ......__.:....$18.00
201.300 Amp Fe=..................,..,,$30,OO
301400 Amp Pee......... .........,....5142,00
401-500 Amp Fee......... ,.............$55.00
501.600 Amp F""'......... ..............$67.00
601-70D Amp ;Fee... no ....m.. ........580.00
701.800 Amp Fn... on... ..._.....__ ...$9.2.00
. 801-900 Amp Fe~.....................$10',00
901-1000 Amp....,. ,.....,. ......, ...:Rl 17.00
IF OVER. 1000 Amp
l~'IOQO Amp Fee..................'117.00
Bl'lch additional 100 Ampa.........$l~.OO
Notice
r hereby ccrtll1 that I hllvt:- rc=lld ilfid. examinec\ 1I1i~
tlppllCi!ltlon lInd kM\V die :;!8ID1i! tll be true lIDd correct. All
pl'Ovisions: of laws lInd o:r<linllnC~ fl;QvClttinj ftli~ type of
WJ;lrk w111 ba complied willi whethe:r sPeQifil;d herein or
not. The e.rll(\~iJ1~ of a pelltlit tloes not p~ume to give
lIuthority to vlolil.t~ or cil.ncellhe provillicllS ofan;y oihEl("
$ll!lt~ or locallliw f"'gullll:ing cQnSl:nlction or th<::
perCormnnllll- Ofllolllllrnlltiol1.
CompllOltion Oabil
ELECTRICAL PERMIT FEES
Upgrade Exifiting ServiCIl.,...,..... ..$10.00
Tempo1'a~'Y Sel.vice............. on.... $10.00
FiR- Alarm System......... ...... ......$10.00
SIgns........,... 1.1 I..... ~.,i"l,"l.,..,.".JH$15100
Misoellaueotl~ Apparatus.....,... .....$11.00
ACIDC Cj,\'cujt.....~.....,....... ........$5.00
Cl;lwmfll'cll1il!Mu)ti FQmily IUltl All Upgrade~:
# ofCirc..ub K SZ.OO
Amp Fee
Amp Fee + Circuit Total
New Ruidtlntial: (Finished Area)
Singl0/Two Family Dwellings
,lA '-1.0 liq. ft. X .045
ModlllarlMllntlfactured Homes.. ,...$50,00
Receptacle/Switch Outlehl
Fixture! ;X; $.75
Smoke Dtltllctors X $3.00
Ruldent(alICcmmercia) Appliance
# Fi'&ed Outlets x $3.00
Motof(S) x $3.00
Power Apparattu-' a20 VOltG)
# Appa.ratu5 x $5.00
Permit IUl1Mce Fee,.,..". ,.,. ...,.. ..$20.00
Comment;
1121..01.:)
..s l .30
Total
{)i)(80
'iJ~" 00
WHEN PROPERLY VALIDATED IN THIS SF ACE THIS IS YOUR PERMIT
Approv~d By; r\ Lcrud h
CITY OF BLAIR
218 SO 16TH ST
BLAIR. liE 68338
(432) 426-6692
Herchant rD: 303309353703
Term rD: 39353733
Ref u: 3032
Phone Order
--.
VISA
Amount:
rax:
r otal:
0911BIOl
Inv #: 000002
Apprvd: Onll ne
AVS Code: EXACf HArCH Y
Order U:
Exp: 02109
Entry Hethod: Hanual
$ 2,545, l3
$ e.e0
~~r~~~2,545,=;3
13:52:41
Appr Code: Ol2439
Batch#: 00014l
I agree to Pay above t
according to car' otal amount
(Herchant agreemen~ :;suerdagreement
cre H Voucher)
x
..--...................................................................
Herchant COpy
THANI< YOU I
CITY OF BLAIR, NEBRASKA
Phone 402-426-4191
RECEIVEDO/0iM1 ~~
'""'''~~
'"",or,,,, ""0", ~ ~ - ~ &e6
c:Rsoa W. ~ o/U' pue
d~~ ~ &85d?qJ
;<?~
dMO~
THANK YOU
NO 2 0 6 8 6
Pounds Printing, Blair, NE 68008
8IJ /. 5'-f
ft.OO < o:?
/30 I . 5*
J
7tftf.''t BJd. ?.IM'1'
SO () . 00 oUf6W
7::1 '1'-1. ,t'f
'BJ cJ. ?.QNffl .
dAfo s1J
KEEP THIS COPY FOR YOUR RECORDS.
,? ;?JI'~
RECEIVED BY
Blair Building Permit Detail
Permit #: 12811 Issued: 9/1/2007
Completed:
Location: 2857 Ravae Ln
Owner: Urban Homes
Address: 2500 W Highridge Circle
Type: Residential - New Construction
Valuation: 139560
Lincoln, NE 68522
Phone: 770 4730
Section: Township:
Subdivision: SOUTHRDG
Permit Fee:
Issue Fee:
Deposit Amt.:
Receipt #:
781.54
20
500
Range:
Lot: 29
Block:
1140 SF Ranch style, 3 bedrooms, 2 bath, unfinished walk out, rough in, attached 2 car garage. Deck off of NE side.
TFA: 2760
Contractors
Urban Homes, LLC
Wolfe Electric
Inspections Date
By
General Contractor Permit #
Electrical Subcontractor E2750
;J.QJ
t"' yn 0 /() 1
q, I '
Issued
9/5/2007
Remarks
SLEEPING ROOMS BELOW THE FOURTH
STORY AND IN B/\SEMENTS ARE
REQUIRED TO HlWE AN EGRESS WINDOW.
~~
MEET IBC, IRC, IPC, IMC AND NEC CODE REQUIREMENTS
08/21/2007 21:11 FAX
,~~ c~ Uf u~:~~a
Brian He5~@r Heating & Ai 402-477-~334
RFScheck C6mpliance Ce'l'tificate
2003 IEee
RES check Software Ven:;iOf( 3.6 Releas~ 2
D:lta filename: Untitloo,rck
PROJECT TITLE: 1180 split entry
CITY; Blair
ST ATE; Ncbfll$ka
IIOD: 6506
CONSTRUCTION TYPE: Single Family
WrN'OOW I WALL RATIO; 0.08
DATE: 08/21/07
DATl:'; OF PLANS: 8-20n2007
PROJECT DESCRIPTrON;
Blair
DES IGNERlCONT R ACTQI;l.;
URBAN
COMPLIANCE: Passes
Maximum. VA"" 354
Your Home VA "'" 302
14.7% BcttcrThan Code'(UA)
Ceiling I; Flat CeiliT.1g or Scisllor Trus!:
Wall 1; Wood Frame, 16" O.c.
Window I: Vinyl Frnml;;Doublc Pan~ with Luw-E
Door I: Solid
WiU] 2; Wood Frame" 16" 0.0.
Window 2: Vinyl !<'rarne:Double Pane with LQw-E
Wall 3: Wood Frnme, Hi" o.c.
Door 2; Sclid
Wall 4: Wood Fr<lmC, 16" ().a.
Basement Walt I: Solid Conro:Lt: ()f Masonry
Wall height: 4.0'
Depth below grade:; 3.0'
Insulation depth: 4.0'
1"1001' 1; All-Wood Jcist/Tross;Over Unconditioned Sp~,-,
Floor 2: Slab-On-Gtwie:\JnhltateQ.
CC1.i"tW-->
Permit Number
f4I 004/005
p.l
.' '1,
Checked By/Datc
('m,ISS Glazing
Area or Cavity Con,. or Door
Pcrimct.cl" R-yalue R-Valuc U-F nc:mr If.6.
Il~O J9.0 19.0 31
1168 13.0 0.0 86
102 0.360 37
21 0.170 4
2G!l 0.0 0.0 55
39 0.360 14
203 13.0 0.0 16
I~ 0.170 3
123 19.0 Q.O 7
268 13,0 0.0 ]9
173
28
19.0
0.0
7.0
8
22.
---., .. '......' "-....-.-.-. - ---- .
08/21/2007 21:11 FAX
,u~ ~~ UI U~:~~a
B~ian H@ste~ Heatin~ ~ Ai 402-4??~3334
141 005/005
p.2
'nsulw.ion depth: 2.0'
FUDI<<<;i: 1: Forced Hot Air. n AFlIE
Air Conditioner I; Elo"otnc Central. Air, 13 SEER
COMPLIANCE ST AT:EMHNT: The pmpos<:d building ~i~'T1 described here is o:msi:stent wHh the building plans.
spedttcations. and other wculatloDs submitted with tbe pcnnit application. The proPQsed building has bo;"n designed to
meet the 2003 lIie,;C J'equirements in REScheck Version 3.6 R(::l~e 2 (ilJ'mcrly MECch{d.-) and to comply with the
rnr.mdatory requlrernllnls listed in the RBSc.heck Inspection Checklist.
Builder/Designer _u
Oale._..
CITY or BLNQ
BUILDING PERMIT SUPPORTING DOCUMENTS
This building permit packet includes various items dealing with particular code
requirements and/or building permit requirements. It in no way includes ALL particular
code items. Also, it is your responsibility to know the 2006 International Buildinq
Code requirements that apply to your project. Please understand this packet is only
designed and distributed to aid you in your building permit process. A copy of the
International Building Code is available for your use at the Blair Public Library.
I have read the above disclosure and accept this building permit documentation on my
own behalf assuming full responsibility as the owner/contractor for this project.
~~/
Owner/Occupant
/)~~ )Io~" LL C
Contractor
City of Blair
Date
(5)-
EQUAlKOUSINO
218 South 16th Street. Blair, Nebraska 68008 . 402-426-4191 . Fax 402-426-4195 . E-mail cityofblair@ci.blair,ne,us ""'''"'''
CITY or BLNQ
..., _\~
^ .~
'VI". 0"
Otnise 01 o,u
BUILDING PERMIT DEPOSIT AGREEMENT
A $500.00 refundable deposit is being collected at the time of your building
permit application for all commercial, new homes and residential
additions/remodels/accessory buildings valued $10,000 or greater. However,
the City reserves the right to not refund this deposit if any of the following
conditions occur during the construction period:
1) theft of water service by either the plumber, owner or general
contractor,
2) all required inspections have not been obtained,
3) occupancy occurs prior to a final inspection,
4) all permits have not been obtained,
5) the project is completed without a final inspection being done.
If any or all of these situations occur during construction, you may forfeit
your deposit.
I, hereby agree to the above conditions, and understand that should any or all
of the above situations occur, the building permit deposit SHALL be
forfeited or discounted upon the discretion of the City of Blair, Building and
Inspections Department.
~,~--
Contractor/Owner
Contractor/Owner
City of Blair
tl 1/6 fOI
Date
(5)-
218 South 16th Street. Blair, Nebraska 68008 . 402-426-4191 . Fax 402-426-4195 . E-mail cityofblalr@cl.blair.ne,us ~::'o'~,OJ:~:
coo/coo ~
r'-'---'.' - -;
I
j
,
f'--
I
i
ir-_, '. ..--
~ --"'"
, I
I :
, 1
I '
. ,
I :
i : I
I : I
i ;
, '
I :
i :
I I
I :
r---,
~I ~ I
)1,,), fla '
01 ~ '
Q, ~ :
I 6 I
. I
I :
. ,
I I
. I
I :
, ,
I
'/
I
j
I
i
I
!
I
i
i
,
I
j
I 84.84' 18' DRIVE
\-...-.....-.".......- ,....".. .-----------"-. -...--..---....-..-
I
,
I
I
I
I
1
,
I
I
-~l.----
H-on.+ 2S I
Jl<~ zs I
S/dL. 7 /
S/de.- 7 /
\
\
\
\
\
\
.
\
\.
\
\
,
\
._..._"'<1 __ c______~......__
25' FRONT YARD
-4' PUBUC wAi.:'it
._~..
l'
.. ._j,CUR~..CUT
RAVAE LANE
lOT 29, alK _; SOUTHERN RIDGE
BLAIR, NEBRASKA
-y-
o .- -_____._
XVd 6C:61 LOOZ/OZ/SO
60.72'
r---------------------------- I----------------------~
i 10 EASEMENT
I
~--------------- ------------------------------\
! 24' REAR YARD
I
I
.
I
I .-------------
,
I :
,
I '
,
I :
,
I '
,
I :
,
I '
,
I :
,
I '
I
I :
;-------,
-10.1 ~ I
f'\J1 (/) I
o I is ,
ql ~ :
I el '
. I
I :
. I
I '
, I
I :
, I
I '
, ,
I :
. ,
I I
, ,
I :
, I
I '
, I
I -~------ ------________
I
I
I
I
,
I
.
I
I
STEPS AS NEEDED
8" MAX RISE
11"TREAD
25' FRONT YARD
84.84'
18' DRIVE
-~-~-~-~-~---~~----------
4' PUBLIC WALK
/ ;t CURB CUT \
RA V AE LANE
LOT 29. BLK~; SOUTHERN RIDGE
BLAIR, NEBRASKA
~t-
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\ \
~\~
\ <Jl N
\ l/l. (,)
\ ~ \~
\ :.<., '-l
" t
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
~-_~_____~...L
\
,
-----------------------1
~OFBLAJR
BUILDING
REPORT
D
LOCATION
NAME OF
DATE INSPECTION REQUESTED-
TIME INSPECTION REQUESTED-
" t....._...
1~':.,__,~
TYPE OF INSPECTION REQUESTED: D CONFERENCE
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
D STATUS CHECK
COMMENTS:
UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
D D
PASSED FAILED
D D
COMMENTS:
ELECTRICAL:D ROUGHIN D FINAL D PERMANENT SERVICE
PARTIAL
COMMENTS:
MECHANICAL:D ROUGHcIN 0 AlcD FURl'jACE D RADIANTHEAT,D FINAL D PARTIAL
COMMENTS:
PLUMBING: D
D
PASSED FAILED
D D
COMMENTS:
o OCCUPANCY GRANTED
ROUOH-'IN~D FINAL
WATERMETERINSTALLED D PARTIAl,
PASSED, FAILED
D D
CONDlTIONAL OCCUPANCY GRANTED
NOTES/REMARKS-
FAXED
BUILDING
REPORT
WASHINGTON COUNTY
LOCATION OF
I 11
I
TIME INSPECTION REQUESTED.lf '
NAME OF
DATE INSPECTION REQUESTED' I
BUILDING:
REQUESTED: 0 CONFERENCE
o DECK FOOTING 0 FRAMING 0 DRYWALL 0 FINAL 0 PARTIAL
o STATUS CHECK
FAILED
o
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
MECHANICAL:O ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSED FAILED
o 0
COMMENTS:
PLUMBING: 0 GROUNDWORK 0 ROUGH-IN 0 FINAL 0 WATERMETERINSTALLED 0 PARTIAL
o PRESSURE TEST
PASSED FAILED
o 0
COMMENTS:
o OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS'
.
- ~
-"i::
-
~
"e...t.c:'~
"-
,._._~~
' ~
.~.
.:-
----
.~ -
--
-
:..-
-
C-''L
.,.
~4
~l.
.' 'JJ, ~
~ .,
~
~ '.\..
... ~...'
:lo"
,
~.
,
~ -,
.~, ~. .'~~
',":. ..~, .:
.j '. -~
~~~. -.;",,---. "
-" ...:~" .
.~.0"~" ~ir'J'" ""Y" ~
......t~"'j......~~, _
~ 'of.~ - ','.- - ,. ....
. ~f"':~ tr ...' >...... ;.0'
, .t._j
.'_ --' If ,-" ;'-.. >:, ;>"...
~'":~;:' ' .f '-,.. ~.
'J'" ..... ".p
, - ;..>'. ....
'f' f
. .". J. _
.,.',/' -, '..
ii.- .(~ ...,.,
....,t .';"
..J~ ~',,~..
-"1"
'\.;;,:.;:,'-~'
,"'.. .
,"=' .'
.
.{ij
.
_'0-,
,
,~
<
~.
.
.
.'
.
.
I'
"
.
J1.:
> -
.~JO:~L-
-.. - ~ -,.",,"
"". -.'.....
- .
>,
1
'".'
.
.
~
~.....~.
....' - - .
-~..,..""
- - ,.~
. ~
:. - -.:~
II;ii . ~'.J,'
.
.
..t-, ' , -
o~Jil1lfll-
L~..
,~
,
.~
. ,
_. ~
-'~-~~
~'"'"
- ....~..,,-., .-;-:""~-
..-.:: -'
.
.
-
"
..,
-
.~
f'" ".
~~-<..
jo",'.' .
, .
.
~'
'"
~:""
:::""
- -
~-
-
,
1.!!;
..:> ~
"
:::r"" ~o_ -
~'Ii!r
~-~::~
':iF'
(l.'.
-
.
....
1"_'-
~
.
,-
"
-
~~'"
. ' ~
..... ~ ..
,-,,"""-'''-'0 ~ -...
":"::'C-~'~
~'- ...->'~..
. ....--;.o_...:-..~";'~
_._,~_ l'^ .._...~--;.......
\ """. 0.'- -<;.~~.,
, ,'-f.. ~;.....-,,;,~ ' ..
....I~~ .-~."i... 'f3I
-k ....J~'"
,-", . ~
''''~/'l~ ~p~
t ,a.;.
'f:l:~ -
. ' (; -J
. ...._'-~ '~........,
..~,!;~~",-----
-~,,",-'.., ./
,
t.
--
-
-
.
.
~$
-1'
ii'~...).
..
,
.
.
~4
... .~.
o'j
- ;;
"
.-;. ,.1;..;....
'-.f '..
"
",--.'
,. v ~'-b;
,. if< ."
P Ol'
'=1-0- .. ."
~'~J
-
-
I
--
;:oor.
~~t, ,,~...r.~, ..rt.ij\. '"
., '... >,'
'~':~'''' ,~~.',:"
._~.
.
''/'t
~.~;.
;;"{'.'
.....'"
,.,-
-
..I:
<.
,,"-"
.
""Il
>-
><
t'T1
o
o
"0
'"0
o
EO
c:::
;;0
-l
;<:I
t'T1
>-
Z
en
"0
t'T1
-3
o
n
o
z
Z
t'T1
n
-l
en
t'T1
;;0
<
n
~
o
z
o
>-
-3
t'T1
o
""Il
Z
en
"'0
t'T1
n
-l
(3
z
$:
>-
o
~
t:C
c<
:j
-",
z
o
-3
t'T1
en
~
t'T1
$:
>-
;;0
'"
"?
o n
o
~
t'I1
Z
-3
en
o
n
n
~
;.-
z
n
><
C':l
i:=::I
;.-
Z
...,
t"i
t::l
~ tsJf
I" I
'"0 0
;<:I ;;0
t'I1 0
en c:::
en Z
C 0
;<:I :E
t'I1 0
.., ;;0
rn A
"'0
o
n
o
Z
t::l
-
>-3
o
Z
;.-
t""
o
n
n
c::
'"
;.-
Z
n
><
C':l
i:=::I
~
>-3
t"i
t::l
~
o
""Il
O:=:
l'
t'T1
o
'"
t""
c::
,.,.
...
I:;l:I
Z
9
;<:I
o
c
o
::r::
~
o
:!l
z
>-
r
o
:E
>-
-3
t'T1
;;0
$:
t'T1
-l
t'T1
;;0
Z
en
-l
>-
r
r
t'T1
o
o
"'0
>-
;;0
-l
;;
r
n
o
$:
$:
t'T1
Z
-l
en
'""0
O~
en
t'T1
o
""Il
O~
t'T1
o
;.<
....
t"l
n
==
;.-
~
n
;.-
t'
o
;;0
o
c:::
o
:;r:
Z
o
>-
n
o
""Il
c:::
;<:I
z
>-
n
t'T1
o
;;0
>-
o
;;
Z
-l
::r::
t'T1
>-
-3
o
""Il
Z
>-
r
o
"0
>-
;;0
-3
;;
r
n
o
$:
$:
t'T1
Z
-l
en
DO
'""0 ;;0
>- 0
;<:I C
.., 0
;; ::r::
r Z
o
'""0
O~
en
t'T1
o
""Il
O~
t'T1
o
t"l
t""
t"l
n
...,
i:=::I
-
n
;.-
t'
""Il
Z
>-
r
o
'""0
t'T1
;<:I
$:
>-
Z
t'T1
Z
-l
en
t'T1
;<:I
<
n
t'T1
o
-3
t'T1
$:
"'0
o
5';:
;<:I
c<
en
t'T1
;;0
<
n
t'T1
o
"'0
;;0
t'T1
n
o
z
Z
t'T1
n
-l
n
o
~
t'T1
Z
-l
en
DO
'""0 en
;1;> t'T1
;<:I :E
.., t'T1
;; ;;0
r ~
"0
"0
O~
en
t'T1
o
""Il
O~
t'T1
o
c:::
>-3
-
t""
=3
-
t"l
rJ)
o
en
t'T1
:E
t'T1
;;0
o
en
t'T1
'""0
-l
n
o
:E
>-
-l
t'T1
;;0
-l
>-
"0
o
;;0
t'T1
$:
o
-l
t'T1
o
:E
>-
-l
t'T1
;;0
en
t'T1
;;0
<
n
t'T1
-3
~
t'T1
Z
en
"'0
t'T1
n
-l
is
o z
;<:I ;;0
c< t'T1
:E '8 (;J ~
>- t'T1 ::r::
~ en t'T1
o ~ ~ ~
~ '~,~ ~
>- 0 w............
~ ~ -~? f
~ ~ ~ ~
~~~~'~
~ ~ ~. ~
~ \J
8 ~ ~
e ~
rJ:J .........
g ..............
tri
<1
~
n
o
$:
$:
t'T1
Z
-l
en
>-3
><
'"
t"l
o
"'l
52
rJ)
....,
t"i
o ~
-
""Il 0
o z
o i:=::I
-l t"i
Z ,0
o g
rJ)
o ;i
t::l
I:;l:I
c::
-
t""
t::l
Z
9
o
t'T1
(')
'"
""Il
o
o
-l
Z
o
o
""Il
;;0
>-
$:
Z
o
o
"0
O~
en
t'I1
o
""Il
O~
t'T1
o
o
>-
-l
t'T1
Z
en
"'0
t'T1
~
(3
z
;;0
t'T1
to
C
t'T1
en
-l
t'T1
o
z
>-
$:
t'T1
o
""Il
o
:E
z
t'T1
"?
r
o
n
>-
-l
is
z
o
""Il
Z
en
"'0
",q
'~~
"-
~
t
\'
0\.
~
~
rCSY
v6\
-l
c<
o
""Il
t:C
r
>-
::a
o
:E
>-
en
::r::
Z
o
-l
o
z
n
o
c:::
Z
-l
c<
~
~
I--l
~
~
I--l
Z
o
I--l
Z
00
~
~
C1
~
I--l
o
Z
;c
~
~
o
;Co
~
~
~
0)
'.)0
j
\
1
I
1
1
J
I
j
~"",
.~
..
.-..\:,
. I~.J'
. .,.~~
~-
'.
'!IJ
~.
"
-,-,-
.-
,
.
~
-
..
"".
'hI~
;;.
~.;.,...
.~_.~
- ':~
~ ,
-
_-O~ C
'~
. , ~ .'
,- ~ -..,' <l,
~~ - - ~-
!.~ -.
..?l~
,
.
.'-'
.
,
"'"
,
^"
~~, .,
-
)'7')
.> ~
'. ~
"",", ~
'~'ll<"
.
"
BUILDING INSPECTION REPORT
~iTY OF BLAIR
LOCATION OF INSPECTION'
. I
If l. /1 \)
NAME OF OWNER' VA hCf/r1 /7/rlYI~l~1-j CONTRACTOR' (" : ,t:l-/7tJl
DATE INSPECTION REQUESTED' C...:2 $ 5' - () /~) TIME INSPECTION REQUESTED' /1- -r
D WASHINGTON COUNTY D OTHER
"7 c;.'Y I:::' J-r i} r' I ~-1 .
?"' L) ._) I I '''-.i:i l/t~LI /y'(.Z-l:-(.,j}
TYPE OF INSPECTION REQUESTED: D CONFERENCE
__............~"'" ~~V''''>r.t-.- ~"IT ':" --,,~~_~ ~ J.L! ~-
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
PERMIT NO' /;;1 t1/ /
("'- .
:rsJ:~tfATUS C~~
PASSED FAILED
D D
CO.MMENTS:
UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
D D
CO.MMENTS:
ELECTRICAL: D ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNECT
D PARTIAL
PASSED FAILED
D D
COMMENTS:
MECHANICAL:D ROUGH-IN 0 AlC D FURNACE D RADIAj'UHEAT D FINAL D PARTIAL
PASSED
o D
COMMENTS:
~"m:
~~~~~,W,~
PLUMBING: D GROUNDWORK D ROUGH-IN D FINAL D WATERMETERINSTALLED D PARTIAL
D PRESSURE TEST
PASSED FAILED
cJ D
:J OCCUPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS'
..
---
"'-~~
-
---
"'- .-..
.....~..-
--':' .....
-
....--'!
.
.
.
,
, ,
."
~:;,.
....
.
,,,,,"
"
.. .
.
oW'--
.
.-" --~.->
...::-.'t
~ r.~j--
/
...
l'.
'.'
~~. .
~~
".~.
.
,
.
:""" ,..i
,
~
.
_~...L-'~
-
,,-.,...
-'
-
-.....~~
-.'-
. ....... ~
-"",
.
'J
-'
-
.,-
,
.
-'
.....;~
.
.'
..
.
.
.
.-
M
,,4...
~.
,
,4
,
,
..
...
~
-
.
.
...
.
-
,~
.
-
-
-
.'~-
"",...
-
--
-
-
,
_.~.
,;; ..
.
~~.. ---., -...~-,-- ."C-._.....,.._.._,:"C"C-,---,--,---,--~."...':-:,..-............,....-,....~~.c--<,~~..~.~~~~~
BUILDING INSPECTION REPORT
:J CITY OF BLAIR
o WASHINGTON COUNTY
o OTHER
LOCATION OF INSPECTION'
;< / /
/(7~! /.; /", ~ //:- ~1 1 /' J
NAME OF OWNER' C/,j I' 4,:':>r, A'1./77,.f;-.~-
. .f'
DATE INSPECTION REQUESTED-ll" - / t? ~ () /3
1 II i?
,.-:;;//ifu J< d (/ ab
,-~)~") j , /. .
CONTRACTOR' ",;,?:<A/ L "i'vf.lt,'f"tJ .L2l4,; U~.
{/
TIME INSPECTION REQUESTED' :?, 't:it:),J 'in' PERMIT NO'
~,...' f
/c;)/3//
TYPE OF INSPECTION
o CONFERENCE
o STATUS CHECK
PASSED FAILED
o 0
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL D FINAL 0 PARTIAL
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE PWD FAILED
~~~-~~~:::_~~-=~=_~ft~~tibFI+~~~~~~=-==_~_=-,
ELECTRICAL: 0 ROUGH IN D FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE D PRECONNECT PASSED FAILED
D PARTIAL D 0
COMMENTS:
MECHANICAL:D ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEAT D FINAL 0 PARTIAL
COMMENTS:
PLUMBING:
o GROUNDWORK D ROUGH-IN 0 FINAL 0 WATER METER INSTALLED 0 PARTIAL
D PRESSURE TEST
PASSED FAILED
D 0
FAILED
D D
COMMENTS:
:J OCCUPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS'
'''!i ~
.
.....
..
~.
~
.~
,,-
~
~.
,
.~'"
-~- - . ,-
',' """",,,'
"'r ....... -.
..,j;1'{' ..~
, .z:.'" - "
, ,.-..
.. .- _l;-"'~ .-
., --~
~
-
-
,
.
f
I
~~ jJr;'--..,J
~
,~
"";>'
.,.......
"
,
,
,..,.-
,
,
..
,
.
. '
*
.
.\
-.
~. '
-, -
'~ . _1_
. 'l<r']'1"''';'
.( '1.:,... l'
:r{V' ;
"., -11 ",,__ ,-,<'r:-
.
-
",
;~
.
-".....
-:r-,....~;.f'l
.~. ..
.....~;;: .'~"
'oil....... ":r.'
-
.
>
-"ro' ,
'.........j.
-- .
....>:s.:..
~>
~<;; \::
.
,.-
..,t__
", -.:..
.
"
4'- ,
.. '--"-'''-
...~- .-
.
.
..
,
.
"
~?i"
:-' ....::11: '::;'.J
i ~. ..
i' J.::" J/'1f2-3 ,.. ~...I.-
I ;'\. ~'-" "l~III'~'
. .,.; b n- &
~
. \
.. ,;.1-' ~t
~'l:'
..'-
'. -'
.
"
"
--
,
--~
~ .
~
,
,
..'
.
If'"
,
Ii" ~O(
;"
.
..
,\ l
,
.
"VfIi Ir-'
T _
1i.~
.
'.
>-,
...
1
.
~~=~~
--- ..
.
~. ~
<.
"
.
,," c..;
...... ;.
" _...1IIIi:
.."J"~
'...........
;r ,-"
, .;:~ L..~
..t. .p"'<r.~
- . ~ . ".. ..
~....- o.
, ...
~,. .
..._. _ 0l...M>
, Q---("
. ~
.
.
"
,-,. -......
~ ~l- -
,
.
L
..
IIli
[
.. .~. ,
.' .' ~
,~,
-..;.'
.
4, , .
.'
..~ ~ ,
"
, ~,.
.
~
,
,
,
,
"
.
.
.
...
.
.
....-;- ..'
'~, -
.....
.
.
,
,
r
.
.
.
..
.
..--
!'
,
-
,~, -I'
, "
-~ '; '. \.,.
--J,:- .
"'L-. '" ~...
, ,
,-
.
-
-.....;..
.
,/,
<
-
'~. -
,
';4'
'c ~ "-
'-
.
~
. ' "ll ,r=
'~;1 >! ,'~~,?;;; ...
,~. ., .. ". .
-,'" .
.J ' f 4
W'4 A~. ,,_
f"~ ':;l:~~~"'-' ,'. :,,/'," ~
r ,';,' . f'. .:).
J. . \ 'I' r'.'..... .... ~,..J:7IA"
..,. " -If::.'-- .-,,- ....;;
" "';;.. ,.I ~ . ";t~J- .
j~ ~\'\;'_" ~..'1.J. "
, .. .~' 'w-. .... '-:' .t
~,~ ,~~
. . ~...... --/'
\,,", (_ 11__;","
.. .....\ ~ ~C'
.... ",J1"" '., ~..& .
~ .~ .. .. -' ~ ".'-,
. '....); "\.1' -r: -; '. --' .
V;",, . l.'~
.!' " r. .1''fJ,,'.....:...-
',.,:'- II" "'Il
~. "':
-
~;~r~
,
...
"
"
.~. r
,
.' .\.~."
,
.
.
~ ,
"
. .
,
/
"~~~~~'~~~.~.---=-~.~:.~,..~~
BUILDING INSPECTION REPORT
'-
&ClTY OF BLAIR 0 WASHINGTON COUNTY 0 ]ER _
LOCATTONOFTNSPECTION' P 13' ,5 '7 litr.tt.<kl ;fl:;t/ct..J2
NAME OF OWNER' t~ !Jet//! //:nYCe4<p~ CONTRACTOR' !-?/bC2>?'J l;l}7'7t./~
DATE INSPECTION REQUESTED' t1 -;7 tJ -0,8 TIME INSPECTION REQUESTED'// ''-...3 CIA ll,f , PERMIT NO'
/ ~'70 1/
./ t-:/t C-> /
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE 0 STATUS CHECK
~~~..JU~ "'~_- ~=:s;,~-"'C!W..a.~~~~~=~==== '"
=-~G 0 FRAMING 0 DRYWALL 0 FWAL 0 ~=~~t!~
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC D WATER TAP 0 REMOTE 0 WATER SERVICE PASSED FAILED
o PARTIAL D 0
COMMENTS:
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
MECHANICAL:O ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSED FAILED
o D
COMMENTS:
PLUMBING:
o GROUNDWORK 0 ROUGH-IN D FINAL 0 WATERMETERINSTALLED 0 PARTIAL
o PRESSURE TEST
P ASSEDF AILED
D 0
COMMENTS:
:J OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS'
BUILDING INSPECTION REPORT
welTY OF BLAIR
D WASHINGTON COUNTY
D OTHER
LOCATION OF INSPECTION:,
,~...'r!5' '" i
/.." /
"
^,"'
,- '...".....-_..,,"
r ".'
CONTRACTOR'
-'I /;'
, ~' ,
7lJ viLe
NAME OF OWNER'
I / ,/ ,l./'ir !.'
./ ,/
~,. .,<'
TIME INSPECTION REQUESTED'
PERMIT NO'
if' /tJ - d 8rz5'
I ? 8i I
DATE INSPECTION
TYPE OF INSPECTION REQUESTED: D CONFERENCE
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
D STATUS CHECK
COMMENTS:
UTILITIES: D SEWER
D PARTIAL
PASSED FAILED
D D
D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
FAILED
D
COMMENTS:
ELECTRICAL: D ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNECT
D PARTIAL
PASSED FAILED
D D
COMMENTS:
MECHANICAL:D ROUGH-IN D AIC D FURNACE D RADIANT HEAT D FINAL D PARTIAL
PASSED FAILED
D 0
COMMENTS:
PLUMBING: D GROUNDWORK D ROUGH-IN D FINAL D WATER METER INSTALLED D PARTIAL
D PRESSURE TEST
PASSED FAILED
D D
COMMENTS:
D OCCUPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS'
INSPECTOR' rid
~~
DATE OF INSPECTION MADE:
o/2~,fJTIMF /~~
FAXED OPPD\BURTREA
TO CONNECT SERVICE: ON
BUILDING INSPECTION REPORT
~ CITY OF BLAIR
LOCATION OF INSPECTION'
NAME OF OWNER- I.i-I ba-}1
o WASHINGTON COUNTY 0 OTHER
-7 C,r- r-j') '--;./ '--;J
~~:"'[7,~, / cJ ,leu C:X:::./M.
- . -"'--7) r-/-/) / .
/L/o7n.LG.J CONTRACTOR- ,,-./~/I L lL/ iI-un 0./-09/)
, - 0
DATE INSPECTION REQUESTED- 7 - Cl - 0[-3 TIME INSPECTION REQUESTED- / ~1-- 0 0 A, t'-!, PERMIT NO- / ;;(/3- / I
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE
,.,.,... ~F~r"7 __ -= ..._~.~,,~
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL 0 FINAL 0 PARTIAL
o STATUS CHECK
,,' "
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
FAILED
D D
COMMENTS:
PASSED FAILED
o D
MECHANICAL:D ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSEl) FAILED
o 0
COMMENTS:
PLUMBING: B';;::-GROUNDWORK~~ROUGH-IN 0 FINAL 0 WATER METER INSTALLED 0 PARTIAL
COMMENTS: ~PRESSURE TEST
o OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
NOTES/REMARKS-
.C,;-":'"
,--,"",=",
'-"_",;,:",":
-'.: '-'
",;<',: ",'.~ ,,-,:,
"""-:'c.,' ;....-0..,; -.
~~
...............
/
".~"'.I&
'.- e,y. JtiJ"1l~
. . .,,J.,, .'
. 1'1,...
"
~
.
.
IQ1~
"P.
;r
, .,e"
'-'()\:'~l~ if
":J., "
. . .~ ,.~
" ,
.....I.'U
- 'a9~~
Jta. ~
'"
"
"
"
"
"
"
-
-
. -
-,"".
-
.
..
l
.
'nmr
Ty
Ho
.
.
r
,
.. .
" .
,
\
~" ..
....
'.
,
,
~
,
, ,
.
~I
.
JI'-VVO lU.j.,j
.,
.
,\
.~~
~
x'
,.,.
- .
. -
.-'~, ':..'.
.,.-' .
- ~. ,.~ - '"
. ,'. -'-~
1. '::;
,
"
.
'"
"
. /.
,
~.
h'.lloli.ilLl ill.. ~
-~'--- --- --'. -,.-.,."_"-~-_~.,,,---~,,~~.~,~~,,,.,...,~,...---,..,..,.,..-=c--~,,--~..=___~,~_.,-,.,,~-,-,~~~.~
BUILDING INSPECTION REPORT
""I
~'CITY OF BLAIR
D WASHINGTON COUNTY
D OTHER
LOCATION OF INSPE~TI?N' I /
NAME OF OWNER' IJ.A:L:Ja'l1 /~j7?lljZl;;"-')
---0--- '
DATE INSPECTION REQUESTED' iJ- /l) - ()8
;:J \;;;{.< 1--/ 77 ~f "---7
c_^ U__) I /<- CA V>:.U/ , C;,L/rl '
, I / I
/ /1/., 17 .c" 'l'J .f/n ~." . /' "'l )
CONTRACTOR' I p//,,-_l.(/r " /...//IU61-<
---
TIME INSPECTION REQUESTED'
r"') .
1-~ 11 '
PERMIT NO' / ;'/'A / I
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE D STATUSCHECK
~-=~-.d<""",,,. ..~~~"'" ~","", ~_ ."""'---.~
== D-=--~~G.:g~:~~=-'-:dED r
~
UTILITIES: D SEWER TAP D SEWER D SEPTIC LJ WATER TAP 0 REMOTE D WATER SERVICE PASSED FAILED
D~IAL DO
ELECTRICAL: D ROUGH IN D FINAL 0 PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNECT
o PARTIAL
COMMENTS:
MECHANICAL:D ROUGH-IN D AlC D FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSED FAlLED
o tJ
COMMENTS:
PLUMBING: 0 GROUNDWORK D ROUGH~IN D FINAL D WATERMETERINSTALLED D PARTIAL
D PRESSURE TEST
COJl,1MENTS:
~ ~~~"""'" ~~.".~~~~~
PASSED FAlLED
D 0
PAS~ED' FAiLED
[r~,~~ 0
~. o::::::G~:q~II~CYa;e 9t15 t#. 3, L
, -'/ ek ~~~ ~/~LJ
TY~eI
1"",
,
'fr.
- -
~
r[mllzoo~ r[i~'PJ~}
. .H
.........
- -
I~'
III
c.
,~
...~
BUILDING INSPECTION REPORT
D CITY OF BLAIR
LOCATION OF INSPECTION'
NAME OF OWNER' t.t;JJ2'~\'.-, J~'\l"'lS\-7
,.--
'!--/~
DATE INSPECTION REQUESTED-
D W ASHlNGTON COUNTY D OTHER
"1 ('''' (~--~J n .D
",< '6..) I VLGArl.U'._~ J../rv
( J!JJ (/J -J- ,
CONTRACTOR' \..;.J I~':l~ ~:_A."V-4
TIME INSPECTION REQUESTED' tJ I c); 30
~ ,5=~/ u - () rJ ~1
PERMIT NO' ! J-:) f) I
TYPE OF INSPECTION REQUESTED: D CONFERENCE DSTATUS CHECK
-- --- ~-- ""d' ~~--- ---------=-
BUILDING: D FOOTING D DECK FOOTING ~ FRAMING D DRYWALL D FINAL D PARTIAL P~SED
COMMENTS:
UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
D D
COMMENTS:
ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVIC~,A~'PRECONNECT
,.....
PARTIAL ,y'
P~ED ~
COMMENTS:
PLUMBING:
D FINAL D WATERMETERINSTALLED D PARTIAL
MECHANICAL:
D FURNACE D RADIANTHEAT D FINAL D PARTIAL
COMMENTS:
~"'''''""",""",,~!r~~~~~tmm';:ta:~~
...",.,.~~-====~';l;l:t..."'.L~~"I:t:;ti';:;:::m::U:;::::~:!i.ZliE'-"""'''"''''''~''''''~~~~=
D OCCUPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED
~ sElliIlL-
NOTES/REMARKS'
uJ1ii
j/;~~
5~
FAXED OPPD\BURT REA
TO CONNECT SERVICE: ON
TIME- / le~ J
,
INSPECTO .
DATE OF INSPECTION MADE:
f'
['Ill'.
-
Ty~~k
~u~u
T
. .
(V
me
..... := .
>..
" >E
" F- ~
"' .
H)~' ,
~~ ~
GP
I >~ I-
>Eo ,~
, .
k
.
.
-
".
- -,,'-- --,---,c-...,.--c'~-~~~'-,,--..,,-----,-~~-- ~_-_.---.,-,,--.,.-~,,~"------'::-'~,~~ ~'~~""~'~--"-"-'---'-'-"'---::,.."..,...,... ~~'~~~~~~_
BUILDING INSPECTION REPORT
o CITY OF BLAIR
o WASHINGTON COUNTY
LOCATION OF INSPECTION'
\ t I' ~ '\ -' \ -, 1 'I", " C ,::'
NAMEOFOWNER l.b .....j 6~' lC\lJ\i l't,..,~t::-,
DATE INSPECTION REQUESTED' \7/11~' I D Y.":.,
.-- .--, t (
CONTRACTOR' ',~)-CL \'\
/'
TIME INSPECTION REQUESTED' i
\ c' ,..~ II
PERMIT NO' c,;,l\ '6,
TYPE OF INSPECTION
BUILDING: 0 FOOTING 0 DECK FOOTING
o CONFERENCE
Q1/'51\1 vvA~ 0 FINAL 0 PARTIAL
o STATUS CHECK
FAILED
o
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
PASSED FAILED
o 0
ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
PARTIAL
FAILED
o
COMMENTS:
ROUGH-IN 0 AlC 0 FURNACE 0 RADIANT HEAT 0 FINAL 0 PARTIAL
FAILED
o
COMMENTS:
PLUMBING: 0 GROUNDWORK Q9 ROUGH-IN 0 FINAL 0 WATER METER INSTALLED D PARTIAL
o PRESSURE TEST
COMMENTS:
FAILED
o
o OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
NOTESIREMARKS'
"'(~"ey.
,
"'tSl~...
~
.
III,;c _,
~ .' -
. -~'
-....~
f~'" ,-f<t., ~ -~...
'~::"'4 ~,_.._...._~. ,~
. ...~,~-~ """ ,". ...
.....--....-:0-_ ~_
_.._~<:tii~
~
-
-
-
.-
-
-y- -v- r.
---;
.
...........
.
( .
I
i
5f tlfJz0Do crrJ4,c
~
~ "
.
, >
. I
.
,
'.'~-"-""~,..\"",,..._..--,........,,-..,..,,-,.,
"TC~~"~~~'._'__"'-'__'__.'~~'~":~..~.,-~.~
BUILDING INSPECTION REPORT
1d?-efTY OF BLAIR
D WASHINGTON COUNTY
D OTHER
"-'-;23:5' '7 11 (/0 C?~?,;~; ,
CONTRACTOR' Ii! 6(2//7 1J;{~7? U~
7 ' C) (/ PERMIT NO' / ,:;lA'I'11
TIME INSPECTION REQUESTED' c>,' ~ <:/
LOCATION OF INSPECTION'
./' f '/
NAME OF OWNER' (~f ,t!;7a-11 /~rj'f'l.t:~
If '/ ,"
DATE INSPECTION REQUESTED' / ~ c;7 I - ()/j
TYPE OF INSPECTION REQUESTED: D CONFERENCE DSTATUS~HECK
-;;;;;:;;G, D~D-;;~.~.-~D.P~ PAS........~AILED,
_.A~ /' f1-{)?f..1dJ!)ttf?~ . D
COMMENTS: ~_ -,
l':~~~~,.,.~__~~~~~~
UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE PASSED FAILED
D PARTIAL [] D
COMMENTS:
ELECTRICAL: D ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNECT
D PARTIAL
FAJiED
D
COMMENTS:
~~
=zw~~~~'"""""'^"""""
MECHANICAL:D ROUGH-IN D AlC D FURNACE D RADlANTHEAT D FINAL D PARTIAL
COMMENTS:
PLUMBING:
PASSED FAILE!:?
D D
COMMENTS:
OCCUPANCY GRANTED D CONDITIONAL OCCUPANCY GRANTED
D GROUNDWORK D ROUGH-IN D FINAL D WATERMETERINSTALLED D PARTIAL
D PRESSURE TEST
PA,'$SED ,FA,ILED
IT] []
NOTES/REMARKS'
~':; " ' ,','; -
A~'
'-~l
07121/2008 02.20 PM
---
-
,-~ .
.;,:IL- --' -:--"-
~ ~...
- - - .......
'--~.:"-' ~-~....
- - -....: ~
-
-n"'"
, .-
:.:~-,:~~-.~---..: ~
. .. -.. .
...,~-~,..
r . - ....'".i-iiP "I'Io~-~.
--#- .......- - - -..". ""!'- -~-
-
~_lo_:,
.
~
.
-.;,.._.~-
-. ......."
--~- .r~.
.....- "
.
~
---~------ ------..- ~ -- "-'--'--- -.,.-7----: - _.-. C'~~~-"-,:.,.,,.,..~'--~-.~F""'..---~-~;.---C"--"
BUILDING INSPECTIONR:EPORT
'~ITY OF BLAIR
o WASHINGTON COUNTY
D OTHER
,'} a K'1' r~/../ n. II a..l (5",/~n,
('-:://~/ ...J, r-1,..., ,--.
LOCATION OF INSPECTION'
NAME OF OWNER' lj.f ,6t;2'i') /~;;~1L-ULJ
DATE INSPECTION REQUESTED' C!_ / / - 08
. \1 /J
CONTRACTOR' ( I cPrri.R
/j)"/.-:)A<
TIME INSPECTION REQUESTED' (. v < OOA '("1,
/ ,~) ;, II
PERMIT NO' c;:x/(:) I ,
TYPE OF INSPECTION REQUESTED: D CONFERENCE
~-- -~-~ --""- -~.... -_.~~=
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
D STATUS CHECK
COMMENTS:
UTILITIES: D SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
D D
COMMENTS:
ELECTRICAL: D ROUGH IN D
D PARTIAL
PASSED FAILED
D D
COMMENTS:
MECHANICAL:D ROUGH-IN D AlC D FURNACE D RADIANTHEAT D FINAL D PARTIAL
PASSED FAILED
D D
COMMENTS:
D GROUNDWORK D ROUGH-IN D FINAL D WATER METER INSTALLED D PARTIAL
D PRESSURE TEST
PASSED FAILED
o D
PLUMBING:
--~""",'
<,- '~.. "'"
~-~
D OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
NOTES!REMARk~', .: '
+-'~':;:=r-~'~ ':....---.
--"C--:!:'-::'--_~_'.~." '~""~'--'--~--"'~""""'-'------"-________~~'~'~'~'~"~~'~~'~~"~---'---'---'~''''''''''''''''~------'-'~~~
BUILDING INSPECTION REPORT
=:J CITY OF BLAIR
D WASHINGTON COUNTY
LOCATION OF INSPECTION'
NAME OF OWNER- lil ( b ,:F V\
eo. C('7
...) O_~
, .-
D OTHER
'D
i'- '\ \) q 'C
J~k. \,1,\ ri S
~l '" _
CONTRACTOR'
l ~'\.
" i
~,AJ ere, ,
ex..
l) "" r) \I
rp/{
c;-'~! ~-r;~' .
(.J~c.,.t"rM>';::-
DATE INSPECTION REQUESTED'
Cl~ }J
TIME INSPECTION REQUESTED'
PERMIT NO'
\) f Ii
TYPE OF INSPECTION
D CONFERENCE
DSTATUS
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
P ASSED FAILED
[] '[]
COMMENTS:
r_<l:?:'1u=........~..e.~~:>:..~r'""'",.'''''''''==<-~~~~~='''''="'~~=''~'''ZZ=''m"'~~~~==''''''==-'m'~--=~~~~~
UTILITIES: 0 SEWER TAP D SEWER D SEPTIC D WATER TAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
[Ic 0
COMMENTS:
ELECTRICAL: D ROUGH IN 0 FINAL
D PARTIAL I) ,~
COMMENTS: {\ e
PERMANENT SERVICE 0 TEMPORARY SERVICE D PRECONNECT
/'
f \ Ij' "
v6V
"J)O f'~>l
r ' -.:"".1
cFAILED
o
MECHANICAL:D ROUGH-IN 0 AlC 0 FURNACE D RADIANTHEAT D FINAL 0 PARTIAL
COMMENTS:
PLUMBING: D GROUNDWORK D ROUGH-IN D PINAL D WATER METER INSTALLED 0 PARTIAL
o PRESSURETEST
P ASSED FAILED
D 0
NOTESIREMARKS'
D OCCUPANCYGRANfED 0 CONDITIONAL OCCUPANCY GRANTED
~r;
.
r-
.:J.~ ~
Q)>~
ell I\-
l>g
-- .-
nr 'tr' hQQ' 'I ''''-''(1'' D)"J
y:! lLIL <:; 'j;J.J':) J. ~
IWdt!2lZQ01llJ.J:J8 PM
,-
.
--
I
cz( CITY OF BLAIR
(
- ---' - .~--- ~----~~~-------=~-~~.~~-, - -- ' - ... ."'....-_.";;:-----!"~ .:.-.::.......--...-. ~..-~ -._--~~--:::- - --..!-~.~~-=-=-'- '--'--"~.
BUILDING INSJlECTI()N:R:EPORT
o WASHINGTON COUNTY 0 OTHER .
LOCATION OF INSPECTION' (~;.?c65'-';7 :;::;4 ",;:9 L /../~
1.4 //,11'1;) )/ ,c _ (~-
NAME OF OWNER' &,c.-./L-/.Jli \.. .r -r(JlY l/C--: :::::;,
/ ') /",,, / ~)
DATE INSPECTION REQUESTED' / C~ /,:f() / C)h TIME INSPECTION REQUESTED'
I ,'"
~1
"C;
CONTRACTOR'
/"/~-'r/
PERMIT NO' / C?t/:'f//
//
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE 12JSTATUS.CHECK
~~~~~~~~ClP."Ilm.~'G.lli~~."",~~~~-=......-=/:;z;.u;.~~~
BUILDING: 0 F6dTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL 0 FINAL 0 PARTIAL PASSED FAILED
o 0
-~
/l /
/7/
'l'
c
',-1
COMMENTS:
UTILITIES: 0 SEWER TAP, 0 SEWER 0 SEPTIC 0 WATERTAP 0 REMOTE D WATER SERVICE
o PARTIAL
CotvIMENTS: .
PASSED FAILED
o 0
""'-.",
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE
o PARTIAL
TEMPORARY SERVICE 0 PRECONNECT
PASSED FAILED
o 0
'~1
COMMENTS:
:.: ~
~~~~~~~"""""""""=~~"~~"""""""'aX!::="I'..~Zl::l'~:::a:::a:=.<=.!.:3:::::~:a'$n:on:;z.:i':"'..z..~
MECHANICAL: D ROUGH-IN 0 AlC 0 FURNACE 0 RADIANT HEAT 0 FINAL 0 PARTIAL
COMMENTS:
PASSED FAILED
o 0
'"~_.; :c:.
..~.,~...................""":~"-,,,,,,:c. ~' '.~~~'~~~'-l""
o dCCUPA.NCYGRANTED Qr CON])lTiQNAEOCClwANCYG~i~k .. ."
_ ~~-S::;;:;>~~~~=-~~
NOTE~!REM~S'
- .' .
.,.. . '
-,:, ' .,'..'-:
;-: .,".' '.
, '~....,',
.~.':' --.:'. . ..-
~
--
" ... ~- ,
, III -
,
..
-
--
.
..IIIII!!!II
- ...
-"--
- -
-
.
-~ ........
...
_.mm.t---
~"....
.,....
12/30/2008 0138 PM
r'71.~~~_~~~.:,_~.~_.._._..'.._::o-_c'C':".'."~'~""';"'<.;..o...,.,....,.".._._."'....~..:..;__-=---::;:...""";..,....~':'.~~.~~.......".''-;---.,,'--,.....C,..._,..'--._. __--....'--,:_. ,.,.-.i...'--..,__._,..,.--""....._"',-'L..,...7C.~.~,....,.".,',..,......:.".,...,::".:..."~,~~_~:..".._"',......,....._.. _"'--c..~~~.=_"-..,, ..._.........'.~
BUILDING INSPECTION REPORT
o CITY OF BLAIR
LOCATION OF INSPECTION'
NAME OF OWNER Ut live; h.
o WASHINGTON COUNTY
J (~C
{f' 0 ..>
o OTHER
Q <1 \J '7 ("
L l~'l
,
I.J\\J (]""
CONTRACTOR'
DATE INSPECTION REQUESTED'
I~ )).
TIME INSPECTION REQUESTED'
f~ )It/'\
PERMIT NO' /~II
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE 0 STATUS CHECK
~===-~ ~~~~~~ZF.:1>~~~
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL 0 FINAL 0 PARTIAL PASSED FAILED
o 0
COMMENTS:
~~-=.."'" ~~~~~~~~~~~~-J!::~...JHZ-~r4r~~
UTILITIES:
o SEWERTA!' o SEWER 0 SEPTiC 0 WATER TAP 0 REMOTE 0 WATERSERVICE
o PARTIAL
PASSED FAILED
o 0
COMMENTS: ,
~~~~"""""'"-"""""".. ,~~
~~~~~W"~-=.'=-'"'=~
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
~~~~
'~~.>3'~l:.~",,-~~~
MECHANICAL:D ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSED FAILED
o 0
PLUMBING; 0 GROUNDWORK 0 ROUGH~IN 0 PINAL 0 WATER METER INSTALLED 0 PARTIAL
o PRESSURgTEST
COMMENTS: ,
o OCCUPANCY GRANTED EJ;cG6ND1TJQNA~~9CCUPANCY dRA.NTED
PASSED FAILED
o 0
NOTES/REMARKS' ,
.~< "
flj,:: AM
&OFBLAffi D :M~::: INSPE~:~~N REPORT
LOCATION OF INSPECTION' L-';;8....S" /7 }r;:;; v/4€ i/l)
/, /.?{ r/J,1! / ) ; /!" ./"
NAME OF OWNER' /L..d!ILJ/lIv 17fJ/t(e~ CONTRACTOR'
DATE INSPECTION REQUESTED' ...:3 J:; 6 ~'9' TIME INSPECTION REQUESTED' ,/-1/{
/ I
TYPE OF INSPECTION REQUESTED: D CONFERENCE
BUILDING: D FOOTING D DECK FOOTING D FRAMING D DRYWALL D FINAL D PARTIAL
PERMIT NO' ,~:?d //
/
[d'STATUS CHECK
,
COMMENTS:
UTILITIES: SEWERTAP D SEWER D SEPTIC D WATERTAP D REMOTE D WATER SERVICE
D PARTIAL
PASSED FAILED
D D
COMMENTS:
PASSED FAILED
D D
ELECTRICAL: D ROUGH IN D FINAL D PERMANENT SERVICE D TEMPORARY SERVICE D PRECONNECT
D PARTIAL
PASSED FAILED
D D
COMMENTS:
.
MECHANICAL:D ROUGH-IN D A1C D FURNACE D RADIANTHEAT D FINAL D PARTIAL
COMMENTS:
PASSED FAILED
D D
_.....~7i"
--.............,,~"~
PLUMBING: D GROUNDWORK D ROUGH-IN D FINAL D WATERMETERINSTALLED D PARTIAL
D PRESSURE TEST
PASSED FAILED
D D
COMMENTS:
""""""'"rtn"""''''''''''''''''m''''\",'''"W<!l.\~'''''''''''1'''''-''''''t..~~__
~OT::=:GRANTED D COikALtrnTI~ 8 j)
'Pf04-S ~
t
FAXED OPPD\BURT REA
TO CONNECT SERVICE: ON
BY
~
-
-~
- .
:- .::,.--
.
.
..
~
~
-~
-
-
.
,
II
II
I
.. --::..::.......
.. ,
~. '.-
-
III.
n
'..
,
."
, -
,~.,f'..t
03/16/2009 01:58 PM
"'-11
.11
,
"
I
I
, I
"
,
I
I
<
- "
-
-
,
-.
..
--...........
.
---~
- ~
_. t...--- .1
.....
- -
----.c::::
-
:/...11 l
- 111.:l
I
- I
I ;
- I
,
-
- -
I... Ii
~ III1I
,
_.~-
..-
.'...
....
..m
....
....
-..
.-.....
,
I
.
-
-
.
~
II
-
~-
.-..
_.2
""....
.....
.1Iil:l_
....
-
, ,
-
...
-
,
II
"."'il',.
>,
~ir-_
-
..
- . ..'~ '
, ~ .. - , -..... - "'" ~ ..,., - -'<<
r.::;~~:"';~_:;.;:l .,til&.;~'''' " ",-. c, '~.....~"""",,-.' . '.::. '-.~'~"'i'?1I
.-- .'r..~ .....'..:. '~:""'I.-~:..S,:.:....-~;;;,;.o:l~1~~~'~; -.,. . .. "SC
" 1'.1:...: ,.,. -\"" ,."... --
.' -!r. .,. .> ,',-", '!IE <,\.~.'.\-(. ..'...~. .._r- ,4. - ."'~'.4W,,:, i'""",,,,~._~,",!
. ';, . .... -"::f<. I '.' .,-"".iI.~ "
.... ,.",,"..,~
''t. ~ _~> .wJo.~'j'...:,'-',:"...<~~ ::'':''''~ -';";;'~$'~:"'';'' ..,..1
." " - .. -T4, i ,c:, ",_ ,....._~ . =-. ,.r......__
,.~ . ,"-- - "- ~ t"i; .'.. .' . ...."""'.w,....
~.._'..Ii:."l~';1'(.._V~'--'~...t".~.."".;. ",,',' :..j..~.:'~_ - .. ..v :; ,,-.;.:. ".___':"'::"'iI~iW:'':''l'''',
,..,:':Iif_~ -_~;'ft;,~._,.,.,_""",. \....-J,._..1>_.,.~,~rr ',- "_',.iJ"""1J1:. .. .",tt..
J<.
_.
'-
:-"), ..
~
~
-
-
-~-
.-
~-.-
~'T"'_I_
....':=-.
-
--
-
~~.,..-,.........,.,..
. -
'--..
.
----
-.
...
.
,.-
.....
,
"
,-
r",HOMEr"',lLC
, 416,56191416_5008
-
-
--
-~
-
-
- -
.
--
"
- -
-
---....,.
....-~.
,
.-.
.
.
....,
-
-'
-~
---
.
....,.
"1' .,....
"":.-
~-
-
-
-
~~
.
-
.. .
-
-
~.
F'_
.~(~I~ OF LAIR
LOCATION OF INSPECTION-
BUILDING INSPECTION REPORT C'{:CLiff~ .
D WASHINGTONCOUNTY 0 OTHER" AJ:r-r ~)1.S!&:fl q:;--
.1:/ '/.. ...f ~FS r:"rl't €-
'\_~<. (:?{r':{',( {',~'}J..<~,::i,,7J' ~
(j,?J{~5~~:_'=j"'" r".~f;?
tf f ! Ii
NAME OF OWNER- /<::'//kti) /'.;~~)In{!/L} CONTRACTOR- /t~i..,l~~w!'(i/ .(7 ~?'t:).... t:,{ ;;;::5~/')
/1.;'_'" ",.f';, ._' ," _' ," ,.~':-_>~,! <::-.:_", :'" __ _ _ :.' _ ''''~''__,::'~- i I
,J~{j ~If~~1>~#~;'l~ /f~'\~~'j'~:{~4W:(~;:;r~~~~~~~;cl.e -~!1~;~)E~~~~~!::~;~:arlJe~
'TXPEOFINSPECTIONREQUESTED: i' - .' "'" I?~. e"r- . D CONFERENCE D STATUS CHECK
BUILDING: ~ EQOTIWJ D DEC FOOT G CJ FRAMING [l :~YWALL1i;j:"FINA~/D PAR,TIAL 11 ' PADSSED F~~
<JiV /3:Ad:5 EI-.. ;?/7{ C/'c,1' IS ~'V.e ~)t( (Ypt -ft5 te;,,// &r E/'!c:-t /"'1 ~
COMMENTS: Ot AJekJe/( f
UTILITIES: D SEWER~. SEWER, D. ~ PTIC D ":ATERTA,J' D REM01E .Q~WATE.R~ERVICE ~ ~/'-.PASSED FAILED
D. PARTI~... S;:,W BecfR~P1 t.eJa/1 J~-4e ffl~ C/~.s7/dCl:J/"'?? F/17? D D
COMME~",,____~~;?I (;;ck ~t(1 t"e:.5 a /1 ~h!Ld' #le/~\ _. ~_
ELECTRICAL: D ROU'FmAL 0 PEI)M. ANE~T SERV E D TEMPORARY SERVI<A D PRliS?~.PC CTTjJ PASSED F~:,~
~RtrA~,~~(ral w(,veS; I joe-t..y 6v,'!ot"he ,o,~Aeq' - D gr
COMMENE.:=~~~~Pet[ bC#1'" ~q~>~i!?raJ~" ",__w_
MECHANICAL: 0 UGH-IN D AlC D F~A.CE. \ [jlL RADI~T ijEA1/Cd"'\F.INAL D PARTIA,L11 \ J &dJ.~ PASSED FAILED
I Be .d11""'--eS~s/flCWIt&/1 ,.c~ ~e/II /.;cJqpej ? wrz./~ . '..I \ D ~
COMMENTS: ' f.} ~~)~ - UrI4C~G . If ~1!!:!!~::Z ~_~
I' -\C.CC,
PLUMBING: 0 GROUNDWORK~UGH-IN: :FwkL Cl \\jl\-T~RMET n-:ST. LED D PARTIAL _ '._ PASSE~. I I
D PRESSURE TESt . {'pr.yl /b ~ f(eit! 0, ~ ~~#e#(.,o c:j:;~e-- t1a.5 D
co~~~_~:~,=_",_"_~~__~,, -s7i1-r. ~. ',(" .s~C' d#e 70 tO~ Sc- ~
o OCCUPANCY GRANTED D CONDITIONAL CCUPA Y GRANTED
/' j
() {l 'i_l~') /"
//
,il:?:(,,{!1
" . "
,( / t::r?'l;/ " \//:;::+:J() ,
//
FAXED OPPD\BURT REA
TOCONNECTSERVICE: ON
BY
BUILDING INSPECTION REPORT
g~CITY OF BLAIR
o W ASlllNGTON COUNTY
o OTHER
,:::<c? if:}
f~~?
")
DATE INSPECTION
NAME OF
TIME INSPECTION REQUESTED' //, ' ::} () l:). /,.1 .
TYPE OF INSPECTION REQUESTED:
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL
o CONFERENCE
o PARTIAL
o STATUS CHECK
P~ED F~
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
ELECTRICAL: 0 ROUGH INPE]" FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
~D
COMMENTS:
MECHANICAL:D ROUGH-IN 0 AlC 0 FURNACE 0 RADIANTHEATC2]j~FINAL 0 PARTIAL
COMMENTS:
PLUMBING:
PASSED FAILED
o ~
GROUNDWORK 0 ROUGH-INt~/'FINAL 0 WATERMETERINSTALLED 0 PARTIAL
PRESSURE TEST
PASSED FAILED
~D
.~ uJA C'r'e" %e-A.1:41 !~cf
$"',1;' er- ~ ~;;' ~
FAXED OPPD\BURT REA
TO CONNECT SERVICE: ON
BY
~J,
~<:,CITY OF BLAIR
BUILDING INSPECTION REPORT
o WASHINGTON COUNTY
o OTHER
NAME OF OWNER'
/ Ji</Jll~~)':~'~:r~!"7
c ~, '" .,.-- .".~
c:;::;l i:;:1 ~.,:~5'" ,I ~/? //(_~~'A. (jl(r .~,,,-,t}
\'.~.,_"._",_1"'
C':; ~,';/:v? .
LOCATION OF INSPECTION'
CONTRACTOR'
/~,/~/ j,() {.>>;l7
.f I'
/t.l~:J?:! ((/,11. .
DATE INSPECTION
4;'~f1
TIME INSPECTION REQUESTED' ,~1: "
")1'
..,,) }'''' ,,''In
, ..__,~ 0,~"" ,.",' (f f l
f
PERMIT NO'
I)' f J
TYPE OF INSPECTION REQUESTED: 0 CONFERENCE
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL [;;;I(,PINAL 0 PARTIAL
o STATUS CHECK
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
PASSED FAILED
o )(:
COMMENTS:
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
o 0
COMMENTS:
MECHANICAL:
PASSED FAILED
o 0
ROUGH-IN 0 NC 0 FURNACE 0 RADIANT HEAT
FINAL 0 PARTIAL
PASSED FAILED
~ 0
COMMENTS:
PLUMBING: 0 GROUNDWORK 0
o PRESSURE TEST
o WATERMETERINSTALLED 0 PARTIAL
PASSED FAILED
;g. 0
COMMENTS:
o OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
"-
NOTES/REMARKS' fc it' >5 /2('JJd'kJl r LeN,... ~~ d- eL-ec-f;fI..(C<i-L
I' ~
SOV(Lc.-e. ~ (' () W,v~lIl.5 rlVsfQ.c-f,c""..v Ct)-;e,.J..J -;;j..~ II
Ii C 1~f)t~,,-!2 /i1A.ee-61 , ~ f6L.JL.j F(Vv~ ~
IJ 0 tJ tf-- :5 <1- d-cJcJ t
+v~t-'
}l4tJ.A-el eo. ~ L 5
)Jote
<:.
N
...(0 cceR.c., /VOlt: ~v'i' C><.
Wi((;.<'"
(f)
.s (j'~e~ 111 ('.Alttf.lL"cf()l~'
J< ~lS fo c}Co f Atvt-e-L (3/jx, (L4.LL f=6~, 'f:1iJ:ir, - ~,f ec; l='L K ~ I~S
INSPECTOR'
~1/+
DATE OF INSPECTION MADE: 7-. 11 -o?
TIMF' J- ! Lfr
FAXED OPPD\BURT REA
TO CONNECT SERVICE: ON
BY
COMMENTS:
UTILITIES: 0 SEWER TAP 0 SEWER 0 SEPTIC 0 WATER TAP 0 REMOTE 0 WATER SERVICE
o PARTIAL
,PASSED FAILED
""t4 ,,' 0
J1ft!
53/<;17Y OF BLAIR
BUILDING INSPECTION REPORT
o WASHINGTON COUNTY
o OTHER
,;/
"' "LOCATION OF INSPECTION'
"'O'i
t" /;,. :J f i
.1/
po , .J~?~' P.!'.o.)
NAME OF OWNER-
CONTRACTOR'
DATE INSPECTION REQUESTED'
'j:;-,>
c/, r 't' TIME INSPECTION REQUESTED'
PERMIT NO' ):J 2 / /
i;.,__, ,
TYPE OF INSPECTION REQUESTED:
BUILDING: 0 FOOTING 0 DECK FOOTING 0 FRAMING 0 DRYWALL
o CONFERENCE
FINAL 0 PARTIAL
o STATUS CHECK
COMMENTS:
ELECTRICAL: 0 ROUGH IN 0 FINAL 0 PERMANENT SERVICE 0 TEMPORARY SERVICE 0 PRECONNECT
o PARTIAL
PASSED FAILED
DO
COMMENTS:
MECHANICAL:D ROUGH-IN 0 Ale 0 FURNACE 0 RADIANTHEAT 0 FINAL 0 PARTIAL
PASSED FAILED
o 0
COMMENTS:
PLUMBING:
PASSED FAILED
o 0
COMMENTS:
o OCCUPANCY GRANTED 0 CONDITIONAL OCCUPANCY GRANTED
o GROUNDWORK 0 ROUGH-IN 0 FINAL 0 WATERMETERINSTALLED 0 PARTIAL
o PRESSURE TEST
PASSED FAILED
o 0
NOTES/REMARKS'
INSPECTOR'
~i/ ,r-,j'
DATE OF INSPECTION MADE:
() ,
t" ,- - l' i
,"':,' i
':,",1 i
FAXED OPPD\BURT REA
TO CONNECT SERVICE: ON
BY