ComCheckCOMcheck Software VerMovp C'ckWeh
Envelope Compliance Certificate
( n�(
Project Information
Energy Code:
2018 IECC
Project Title:
379 S 3rd Ave
Location:
Blair, Nebraska
Climate Zone:
5a
Project Type:
New Construction
Construction Site: Owner/Agent:
Designer/Contractor:
Additional Efficiency Package(s)
Credits: 1.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Building Area
Floor Area
1-Warehouse : Nonresidential
4800
Envelope Assemblies
Assembly
Gross Area
Cavity
Cont. Proposed
Budget U-
or
R-Value
R-Value U-Factor
Factor(.)
Perimeter
Roof: Attic Roof, Wood joists, [Bldg. Use 1 - Warehouse]
4800
0.0
40.0 0.024
0.027
Floor: Unheated Slab -On -Grade, [Bldg. Use 1 - Warehouse] (b)
280
---
--- 0.730
0.540
EAST
Ext, Wall: Wood -Framed, 241n. o.c., [Bldg. Use 1 - Warehouse]
3358
19.0
0.0 0.065
0.064
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Warehouse]
19
---
--- 0.077
0.370
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Warehouse]
19
---
--- 0.077
0.370
Door: Insulated Metal, Swinging, (Bldg, Use 1 - Warehouse]
19
---
--- 0.077
0.370
Door: Insulated Metal, Swinging, [Bldg, Use 1 - Warehouse]
19
---
--- 0.077
0.370
Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1-
168
---
--- 0.100
0.310
Warehouse]
Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1-
168
---
--- 0.100
0.310
Warehouse]
Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1-
168
---
--- 0.100
0.310
Warehouse]
Door: Insulated Metal, Garage door 14% glazing, (Bldg, Use 1-
168
---
0.100
0.310
Warehouse]
Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1-
168
---
--- 0.100
0.310
Warehouse]
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) Slab -On -Grade proposed and budget U-factors shown in table are F-factors.
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 1 of 18
O-
Envelope Compliance Statement
Name - Title Signz)ture Date
Project Title; 379 S 3rd Ave Report date; 02/07/24
Data filename; Page 2 of 18
8
Interior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Construction Site:
2018 IECC
379 S 3rd Ave
New Construction
Owner/Agent:
Designer/Contractor:
Additional Efficiency Package(s)
Credits: 1.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts / ft2
1-Warehouse Storage: Smaller, Hand -Carried Items 4800 0.62 2976
Total Allowed Watts = 2976
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
1-Warehouse Storage:Smaller, Hand -Carried Items
LED: LED Panel 19W: 6 9 19 171
Total Proposed Watts = 171
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist
Name - Title Signature Date
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 3 of 18
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
2018 IECC
379 S 3rd Ave
New Construction
2 (Light industrial area with limited nighttime use (LZ2))
Owner/Agent:
Allowed Exterior Lighting Power
A
Area/Surface Category
Designer/Contractor:
B C D E
Quantity Allowed Tradable Allowed Watts
Watts / Wattage (B X C)
Driveway 2700 ft2 0,04 Yes 108
Total Tradable Watts (a) = 108
Total Allowed Watts = 108
Total Allowed Supplemental Watts (b) = 400
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces,
(b) A supplemental allowance equal to 400 watts may be applied toward compliance of both non -tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Driveway (2700 ft2): Tradable Wattage
LED: LED Other Fixture Unit 6.5W:
4 4 16
Total Tradable Proposed Watts = 16
Name - Title Sjgc nature Date
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 4 of 18
8
Project Information
Energy Code:
2018 IECC
Project Title:
379 S 3rd Ave
Location:
Blair, Nebraska
Climate Zone:
5a
Project Type:
New Construction
Construction Site: Owner/Agent:
Additional Efficiency Package(s)
Credits: 1.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Mechanical Systems List
Quantity System Type & Description
1 HVAC System (Single Zone w/ PerimeterSystem):
Heating: 1 each - Radiant Heater, Gas, Capacity Unknown
No minimum efficiency requirement applies
1 HVAC System (Single Zone w/ PerimeterSystem):
Heating: 1 each - Radiant Heater, Gas, Capacity Unknown
No minimum efficiency requirement applies
1 Water Heater:
Electric Instantaneous Water Heater, Capacity: 0 gallons
No minimum efficiency requirement applies
1 Water Heater:
Electric Instantaneous Water Heater, Capacity: 0 gallons
No minimum efficiency requirement applies
Mechanical Compliance Statement
Designer/Contractor:
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit, application. The proposed mechanical systems have been
designed to meet the 2018 IECC requirements in COMcheck Version CO fMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist,
r
Name - Title Si9nature Date
Project Title: 379 S 3rd Ave
Data filename:
Report date: 02/07/24
Page 5 of 18
COMcheck Software VerMo" OuMchec, W
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 7.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided,
Section
#
Plan Review
Complies?
& Req.lD
_
C103.2
! Plans and/or specifications provide all❑Complies
[PR1]1
information with which compliance
❑Does Not
can be determined for the building
❑Not Observable
,envelope and document where
❑Not Applicable
exceptions to the standard are
claimed,
C103.2
Plans, specifications, and/or
[]Complies
[PR2]1
calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the mechanical
❑Not Applicable
systems and equipment and
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
C103.2
Plans, specifications, and/or
❑Complies
[PR3]1
calculations provide all information
[]Does Not
with which compliance can be
❑Not Observable
:determined for the service water
❑Not Applicable
heating systems and equipment and
document where exceptions to the
',standard are claimed. Hot water
system sized per manufacturer's
;sizing guide.
C103,2
!Plans, specifications, and/or
❑Complies
[PR4]1
calculations provide all information
❑Does Not
;with which compliance can be
❑Not Observable
determined for the interior lighting
Applicable
sand electrical systems and equipment❑Not
and document where exceptions to
;the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
,bulbs and ballasts, transformers and
control devices.
C103.2 I Plans, specifications, and/or
❑Complies
[PR8]1 calculations provide all information
❑Does Not
with which compliance can be
❑Not Observable
determined for the exterior lighting
Applicable
and electrical systems and equipment❑Not
and document where exceptions to
the standard are claimed, Information
provided should include exterior
,lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices,
C402.4,1 ;The vertical fenestration area <= 30
❑Complies
[PR10]1 percent of the gross above -grade wall
❑Does Not
area,
❑Not Observable
❑Not Applicable
Ccorrawnents/Assumptions
11 High Impact (Tier 1)_12 Medium Impact (Tier 2) _1 3-] Low -Impact (Tier 3)
Project Title; 379 5 3rd Ave
Data filename:
Report date; 02/07/24
Page 6 of 18
# Plan Review
& Req ID
C402.4.1 The skylight area <= 3 percent of the
[PR11]1 gross roof area,
Complies'? Comments/Assumptions
ElComplies
FlDoes Not
r]Not observable
EINot Applicable
C402.4.2
In enclosed spaces > 2,500 ft2
ElComplies
[PR14]1
directly under a roof with ceiling
E]Does Not
heights >15 ft. and used as an office,
FINot observable
;lobby, atrium, concourse, corridor,
E]Not Applicable
,storage, gymnasium/exercise center,
� convention center, automotive
�service, manufacturing, non -
!refrigerated warehouse, retail store,
!distribution/sorting area,
'transportation, or workshop, the
�following requirements apply: (a) the
daylight zone under skylights is > =
half the floor area; (b) the skylight
area to daylight zone is >= 3 percent
'with a skylight VT >= 0.40; or a
minimum skylight effective aperture
>= 1 percent.
C406
'Plans, specifications, and/or
ElComplies Requirement will be met.
[PR9]1
calculations provide all information
E]Does Not
;with which compliance can be
nNot observable
determined for the additional energy
E]Not Applicable
efficiency package options.
Additional Comments/Assumptions:
FiTHi- J�=2Medk�mnm
gh Impact (Tier 1) act (Tier 2) 3 Low Impact (Tier 3)
Project Title, 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 7 of 18
Se
c'ion
#
Footing / Foundation inspection
complies'?
Comments/Assumptions
C303.2
Slab edge insulation installed per
ElComplies
[F0412
manufacturer's instructions,
InDoes Not
nNot observable
E]Not Applicable
C303.2.1
Exterior insulation protected against
OComplies
[F0611
damage, sunlight, moisture, wind,
FlDoes Not
�landscaping and equipment
nNot Observable
:maintenance activities.
[:]Not Appl !cable
C105
:Installed slab -on -grade insulation type
ElComplies See the Envelope Assemblies table for values.
[F03]2
and R-value consistent with insulation
E]Does Not
,specifications reported in plans and
FINot Observable
COMcheck reports.
EINot Applicable
C402.2.4
Slab edge insulation depth/length.
Dcomplies See the Envelope Assemblies table for values.
[F07]2
Slab insulation extending away from
E]Does Not
building is covered by pavement or
F-INot Observable
>= 10 inches of soil.
C403,12.2
Snow/ice melting system and freeze
OComplies
I
I protection systems have sensors and
E]Does Not
C403.12.3
'controls configured to limit service for
PNot Observable
[F09]3
pavement temperature and outdoor
ONot Applicable
temperature. future connection to
Add|t]mnaUCsnmmoemts/Aymunnpboms:
_LL��igh impact (Tier 1_ F2]Mediurn Impact (Tier 2) —3] Low ct (Tier
Project Title: a7sS3rdAve Report date' 02/07/24
Data filename: Page 8m 18
& Req . I DT
FINot Observable
EINot Applicable
C303.1.3
!,Fenestration products are certified as
ElComplies
[FR13]1
�to performance labels or certificates
E]Does Not
provided.
nNot Observable
E]Not Applicable
C402.4.3
'Vertical fenestration SHGC value.
OComplies See the Envelope Assemblies table for values.
�nNot Observable
E]Not Applicable
C402.4.3,
Installed vertical fenestration LI-factor
ElComplies See the Envelope Assemblies table for values.
C402.4.3.
;and SHGC consistent with label
F]Does Not
4
specifications and as reported in plans
nNot Observable
E]Not Applicable
C402.5.1.
'The building envelope contains a
ElComplies
2.1
continuous air barrier that is sealed in
ElDoes Not
[FR1911
an approved manner and material
nNot Observable
E]Not Applicable
barrier penetrations are sealed in an
;approved manner.
C402.5.2,
Factory -built fenestration and doors
ElComplies
C402.5.4
are labeled as meeting air leakage
E]Does Not
FR1813
requirements.
nNot Observable
E]Not Applicable
C402.5.7
�Vestibules are installed on all building
ElComplies
[FR17]3
entrances. Doors have self -closing
ElDoes Not
devices.
F]Not Observable
EINot Applicable
Additioma|Comnmnemta/Assmmmpdmns:
F1THIgh Impact (Tier
Project Title: a7ssandAve Report date: 02/07/24
Data filename: page 9m 18
Section
#
Plumbing Rough -in Inspection
Complies'? Comments/Assumptions
R .113
�1__
_§
C404.5,
Heated water supply piping conforms
ElComplies
C404.5.1,
'to pipe length and volume
FIDoes Not
C404.5.2
:requirements. Refer to section details.
nNot Observable
[PL6]3
E]Not Applicable
C404.6.3
Pumps that circulate water between a
ElComplies
[PL7]3
'heater and storage tank have controls
E]Does Not
that limit operation from startup to
FINot Observable
<= 5 minutes after end of heating
EINot Applicable
cycle,
C404.7
Demand recirculation water systems
ElComplies
[PI_8]3
have controls that start the pump
E]Does Not
upon receiving a signal from the
E]Not Observable,
action of a user of a fixture or
-EINot Applicable
appliance and limits the temperature
of the water entering the cold -water
!piping to 104°F.
Additional
Comments/Assumptions:
01High Impact (Tieri) 2]Medium 31 Low Impact (Tier 3)
---------
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 10 of 18
Sectiokt
#
Mechanical Rough in Inspection
Corriplies:3 orraments/Assumptions
C402,2,6
!Thermally ineffective panel surfaces of❑Complies
[ME41]3
sensible heating panels have
❑Does Not
insulation >= R-3,5,
❑Not Observable
❑Not Applicable
C402,5.5,
Stair and elevator shaft vents have
❑Complies
C403,2,4,
motorized dampers that automatically
!❑Does Not
3
close, Refernece section C403.7J for
❑Not Observable
[ME3]3
operational details,
❑Not Applicable
C403,7,7
;Outdoor air and exhaust systems have
❑Complies
[ME58]3
' motorized dampers that automatically❑Does
Not
shut when not in use and meet
❑Not Observable
maximum leakage rates. Check
gravity dampers where allowed,
❑Not Applicable
Reference section language for
operational details,
C403,11,3,I
HVAC piping insulation insulated in
❑Complies
[ME61]2<
accordance with Table C403.11.3.
❑Does Not
Insulation exposed to weather is
❑Not Observable
protected from damage and is
provided with shielding from solar
❑Not Applicable
radiation.
C403,8.1
HVAC fan systems at design
❑Complies See the Mechanical Systems list for values,
[ME65]3
conditions do not exceed allowable
❑Does Not
'fan system motor nameplate hp or fan
❑Not Observable
system bhp,
❑Not Applicable
C4018,3
' Fans have efficiency grade (FEG) >=
❑Complies
[ME117]2
67. The total efficiency of the fan at
❑Does Not
the design point of operation <= 15%
❑Not Observable
of maximum total efficiency of the
❑Not Applicable
fan.
C403.12.1 ! Systems that heat outside the building'❑Complies
[ME71]2-``"
envelope are radiant heat systems
'❑Does Not
,controlled by an occupancy sensing
❑Not Observable
device or timer switch.
❑Not Applicable
C403,2.2
;Natural or mechanical ventilation is
❑Complies
[ME59]1
provided in accordance with
❑Does Not
International Mechanical Code
❑Not Observable
Chapter 4, Mechanical ventilation has
capability to reduce outdoor air supply
❑Not Applicable
to minimum per IMC Chapter 4.
C403J,1
;Demand control ventilation provided
❑Complies
[ME59]1
for spaces >500 ft2 and >25
❑Does Not
people/1000 ft2 occupant density and❑Not
Observable
served by systems with air side
economizer, auto modulating outside
❑Not Applicable
air damper control, or design airflow
>3,000 cfm,
C403.7,2
Enclosed parking garage ventilation
❑Complies
[ME115]3
has automatic contaminant detection
❑Does Not
and capacity to stage or modulate
❑Not Observable
fans to 50% or less of design capacity.
❑Not Applicable
C403,7,6
HVAC systems serving guestrooms in❑Complies
[ME141]3
'Group R-1 buildings with > 50
❑Does Not
guestrooms: Each guestroom is
❑Not Observable
provided with controls that
❑Not Applicable
automatically manage temperature
,setpoint and ventilation (see sections
C403J.6,1 and C403,7.6.2),
1 High Impact (Tier i) Medium Impact (Tier 2)—� 3 ]Low Impact (Tier 3)
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 11 of 18
Section
#
f�echanical Rough -In Inspeetion
Complies:
Comments/Assumptions
& Req.113
C403.7.4 I Exhaust air energy recovery on
❑Complies
[ME57]1 !systems meeting Table C403.7.4(1)
❑Does Not
,and C403,7.4(2).
❑Not Observable
❑Not Applicable
C403.7,5 ',Kitchen exhaust systems comply with❑Complies
[ME116]3 'replacement air and conditioned
I[]Does Not
,supply air limitations, and satisfy hood
❑Not Observable
rating requirements and maximum
❑Not Applicable
exhaust rate criteria.
C403.11.1 HVAC ducts and plenums insulated in
❑Complies
accordance with C403.11,1 and
❑Does Not
C403.11.2 constructed in accordance with
❑ Not Observable
[ME60]2 C403,11,2, verification may need to
❑Not Applicable
occur during Foundation Inspection.
C403.4.1. Heating for vestibules and air curtains
❑Complies
4 with integral heating include
❑Does Not
[ME63]2 automatic controls that shut off the
❑Not Observable
heating system when outdoor air
❑Not Applicable
temperatures > 45F, Vestibule
heating and cooling systems
controlled by a thermostat in the
vestibule with heating setpoint <=
60F and cooling setpoint >= 80F.
C408,2.2. :Air outlets and zone terminal devices
❑Complies
1 have means for air balancing.
❑Does Not
[ME53]3
❑Not Observable
❑Not Applicable
C403.5, Refrigerated display cases, walk-in
❑Complies
C403.5.1, coolers or walk-in freezers served by
❑Does Not
C403.5.2 remote compressors and remote
❑Not Observable
[ME123]3 ;condensers not located in a
❑Not Applicable
condensing unit, have fan -powered
condensers that comply with Sections
I C403.5.1 and refrigeration compressor'
systems that comply with C403,5,2,.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 ;Low Impact (Tier 3)
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 12 of 18
section
Rough -In Electrical # Rough -in Electrical Inspection
Complies? Comments/Assumptions
& Reci.113
C405.2.2. Spaces required to have light-
Elcomplies
2 reduction controls have a manual
ElDoes Not
[EL22]1 !control that allows the occupant to
FJNot Observable
( reduce the connected lighting load in
E]Not Applicable
;a reasonably uniform illumination
pattern >= 50 percent,
C405.2.1, Occupancy sensors installed in
ElComplies
C405.2.1, classrooms/lecture/training rooms,
E]Does Not
1 conference/meeting/multi purpose
FINot Observable
[EL18]1 rooms, copy/print rooms,
�lounges/breakrooms, enclosed offices,
E]Not Applicable
open plan office areas, restrooms,
storage rooms, locker rooms,
,warehouse storage areas, and other
:spaces <= 300 sqft that are enclosed
by floor -to -ceiling height partitions.
Reference section language
lC405.2.1.2 for control function in
warehouses and section C405,213
!for open plan office spaces.
C405.2.1. Occupancy sensors control function in
ElComplies
2 warehouses: In warehouses, the
DDoes Not
[EL19]1 !!lighting in alsleways and open areas is
FI Not Observable
controlled with occupant sensors that
�
ONot Applicable
automatically reduce lighting power
by 50% or more when the areas are
'unoccupied. The occupant sensors
control lighting in each aisleway
independently and do not control
lighting beyond the aisleway being
controlled by the sensor.
C405.2.1. Occupant sensor control function in
ElComplies
3 open plan office areas: Occupant
�RDoes Not
[EL20]1 ,sensor controls in open office spaces
FINot Observable
300 sq.ft. have controls 1)
configured so that general lighting can
E]Not Applicable
be controlled separately in control
.zones with floor areas < = 600 sq.ft.
within the space, 2) automatically turn
off general lighting in all control zones
,within 20 minutes after all occupants
;have left the space, 3) are configured
so that general lighting power in each
control zone is reduced by >= 80% of
�the full zone general lighting power
;within 20 minutes of all occupants
leaving that control zone, and 4) are
configured such that any daylight
responsive control will activate space
general lighting or control zone
general lighting only when occupancy
for the same area is detected,
C405.2.2, Each area not served by occupancy
ElComplies
C405.2.2. sensors (per C405,2, 1) have time-
E]Does Not
1, switch controls and functions detailedF-lNot
'in
Observable
C405.2.2. sections C405.2.2.1 and C405.2,2.2.,
E] Not Applicable
2
[EL21]2
3 - 110 - _21— — - - --w Impact (Tier 3)
_ Medium Impact (Tier 2) I
11 High Impact (Tier 14__7
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 13 of 18
Section
r
#
Rough -in Electrical inspection
Complies"? I
Cornments/Assumptions
& Req.lt3
)
C405.2.3,
",Daylight zones provided with
❑Complies
C405.2.3.
! individual controls that control the
❑Does Not
1,
lights independent of general area
❑Not Observable
C405.2.3.
;lighting. See code section C405,2,3
❑Not Applicable
2
Daylight -responsive controls for
[EL23]2
applicable spaces, C405.23,1 Daylight,
responsive control function and
section C405,23.2 Sidelit zone,
C405,2.4
Separate lighting control devices for
❑Complies
[EL26]1
uses installed per approved
❑Does Not
,specific
lighting plans.
❑Not Observable
❑Not Applicable
_
C405.2,4
'Additional interior lighting power
❑Complies
[EL27]1
allowed for special functions per the
❑Does Not
,approved lighting plans and is
;automatically controlled and
❑Not Observable
separated from general lighting,
❑Not Applicable
C405,2.5
Manual controls required by the
❑Complies
[EL28]na0
energy code are in a location with
❑Does Not
'ready access to occupants and
located where the controlled lights are❑Not
Observable
visible, or identify the area served and❑Not
Applicable
their status.
C405,2.6
:Automatic lighting controls for exterior'❑Complies
[EL30]na0
lighting installed. Controls will be
❑Does Not
daylight controlled, set based on
❑Not Observable
business operation time -of -day, or
reduce connected lighting > 30%
❑Not Applicable
C405.3
Exit signs do not exceed 5 watts per
❑Complies
[EL6]1
face,
❑Does Not
❑Not Observable
❑Not Applicable
C405.6 `
Low -voltage dry -type distribution
❑Complies
Exception: Requirement does not apply,
[EL26]2
electric transformers meet the
❑Does Not
minimum efficiency requirements of
❑Not Observable
..'..Table
C405.6,
❑Not Applicable
C405.7
Electric motors meet the minimum
❑Complies
Exception: Requirement does not apply.
[EL2712
efficiency requirements of Tables
❑Does Not
C405.7(1) through C405,7(4),
Observable
Efficiency verified through certification'❑Not
❑Not Applicable
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist),
C405;8,2,
'Escalators and moving walks comply
❑Complies
Exception: Requirement does not apply,
C405,8.2.
:with ASME A17,1/CSA B44 and have
❑Does Not
1
automatic controls configured to
Not Observable
[EL28]2
reduce speed to the minimum
permitted speed in accordance with
❑Not Applicable
pp
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
_
C405.9_
Total voltage drop across the
❑Complies
Exception: Requirement does not apply,
[EL29]2
combination of feeders and branch
❑Does Not
circuits <= 5%.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 12 Medium Impact (Tier 2) �3 Low Impact (Tier 3)
Project Title: 379 S 3rd Ave Report date; 02/07/24
Data filename: Page 14 of 18
Section
#
FInsulation Inspection
Complies? I
Comments/Assumptions
& Req.ID
_ _
C303,1
Roof insulation installed per
❑Complies
[IN3]1
: manufacturer's instructions. Blown or❑Does
Not
;poured loose -fill insulation is installed❑Not
Observable'
;only where the roof slope is <=3 in
12
❑Not Applicable
J
C402.2.1
;Insulation installed on a suspended
❑Complies
[IN20]1
ceiling having ceiling tiles is not being❑Does
Not
;specified for roor/ceiling assemblies,
❑Not Observable
.Continuous insulation board installed
in 2 or more layers with edge joints
❑Not Applicable
offset between layers.
C303,1
(Building envelope insulation is labeled❑Complies
[IN10]z
with R-value or insulation certificate
❑Does Not
providing R-value and other relevant
❑Not Observable'
data.
❑Not Applicable
_
C303.2
,Above -grade wall insulation installed
❑Complies
[IN7]1
per manufacturer's instructions,
❑Does Not
❑Not Observable'
❑Not Applicable
_
C105
Installed above -grade wall insulation
❑Complies
See the Envelope Assemblies table for values.
[IN6]1
type and R-value consistent with
❑Does Not
insulation specifications reported in
❑Not Observable
I plans and COMcheck reports,
❑Not Applicable
C402.2.3
'', Installed floor Insulation type and R-
❑Complies
See the Envelope Assemblies table for values,
[IN8]2
value consistent with insulation
❑Does Not
;specifications reported in plans and
❑Not Observable
COMcheck reports,
❑Not Applicable
C402.2,6
Radiant panels and associated
❑Complies
[IN18]3
components, designed for heat
❑Does Not
transfer from the panel surfaces to the,❑Not
Observable
occupants or indoor space are
❑Not Applicable
insulated with a minimum of R-3,5,
C105
I Installed roof insulation type and R-
❑Complies
See the Envelope Assemblies table for values.
[IN2]1
value consistent with insulation
❑Does Not
,specifications reported in plans and
❑Not Observable
�COMcheck reports. For some ceiling
'systems, verification may need to
❑Not Applicable
occur during Framing Inspection,
C402.5,1.
;All sources of air leakage in the
❑Complies
1
building thermal envelope are sealed,❑Does
Not
(IN1]1
caulked, gasketed, weather stripped
❑Not Observable
or wrapped with moisture vapor -
,permeable wrapping material to
❑Not Applicable
;minimize air leakage,
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 Low Impact (Tier 3)
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 15 of 18
.
section
#
Final inspection
Complies Comments/Assumptions
& Req.i®
_
C303.3,
!Furnished O&M instructions for
❑Complies
C408,2.5.
I systems and equipment to the
❑Does Not
2
[F117]3
building owner or designated
representative.
❑Not Observable'
❑Not Applicable
C303.3,
' Furnished O&M manuals for HVAC
❑Complies
C408,2,5.
isystems within 90 days of system
❑Does Not
3
[F18]3
acceptance.
❑Not Observable
❑Not Applicable
—
C402.5.6
' Weatherseals installed on all loading
❑Complies
[F137]1
dock cargo door openings and provide'❑Does
Not
direct contact along the top and sides
❑Not Observable
of vehicles parked in the doorway,
❑Not Applicable _
C402.5.8
Recessed luminaires in thermal
❑Complies
[F126]3
envelope to limit infiltration and be IC❑Does
Not
rated and labeled. Seal between
,❑Not Observable'
interior finish and luminaire housing,
❑Not Applicable
C403.2,2
HVAC systems and equipment
❑Complies
[F127]3
capacity does not exceed calculated
❑Does Not
loads,
❑Not Observable
❑Not Applicable
C403.2.4.
,Heating and cooling to each zone is
❑Complies
1
controlled by a thermostat control.
❑Does Not
[F147]3
Minimum one humidity control device
❑Not Observable
per installed'
humidification/dehumidification
❑Not Applicable
system.
C403.4.1.
'.Thermostatic controls have a 5 °F
_
❑Complies
2
'deadband,
❑Does Not
(F138]3
❑Not Observable
❑Not Applicable
C403.2.4.
'Temperature controls have setpoint
❑Complies
1.3
overlap restrictions.
[]Does Not
[F120]3
❑Not Observable
❑Not Applicable
C403.2,4.
Each zone equipped with setback
❑Complies
2
controls using automatic time clock or
❑Does Not
[F139]3
programmable control system.
❑Not Observable
]Not Applicable
C403.2,4,
(Automatic Controls: Setback to 55°F
❑Complies
2.1,
(heat) and 85°F (cool); 7-day clock,, 2-
❑Does Not
C403.2.4,
hour occupant override, 10-hour
❑Not Observable
2.2
[F140]3
backup
❑Not Applicable
C404.3
:Heat traps installed on supply and
❑Complies
[F111]3
discharge piping of non -circulating
❑Does Not
systems.
❑Not Observable
❑Not Applicable
C404.4.
All piping insulated in accordance with ❑Complies
[F125)2
section details and Table C403,11,3.
❑Does Not
❑Not Observable
❑Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) �3 Low Impact (Tier 3)
Project Title: 379 S 3rd Ave Report date: 02/07/24
Data filename: Page 16 of 18
#
Final Inspection
Complies?
Comments/Assumptions
C405.4.1
Interior installed lamp and fixture
ElComplies See the Interior Lighting fixture schedule for values.
[FI1811
lighting power is consistent with what
E]Does Not
,is shown on the approved lighting
FlNot Observable
plans, demonstrating proposed watts
EINot Applicable
are less than or equal to allowed
C405.5.1
Exterior lighting power is consistent
[komplies See the Exterior Lighting fixture schedule for values.
[FI1911
:with what is shown on the approved
E]Does Not
,lighting plans, demonstrating
� proposed watts are less than or equal
FINot Observable
'!to allowed watts.
'E]Not Applicable
C408.1.1
Building operations and maintenance
ElComplies Requirement will be met,
F15711
documents will be provided to the
DDoes Not
owner. Documents will cover
nNot Observable
manufacturers' information,
;specifications, programming
E]Not Applicable
procedures and means of illustrating
to owner how building, equipment and
;systems are intended to be installed,
� maintained, and operated.
C408.2.1
!Commissioning plan developed by
ElComplies
[F12811
;registered design professional or
FIDoes Not
:approved agency.
FJNot Observable
C408.2.3.
'HVAC equipment has been tested to
ElComplies
1
:ensure proper operation,
;,[]Does Not
FlNot Observable
E]Not Applicable
C408.2.3.
'HVAC control systems have been
ElComplies
2
�tested to ensure proper operation,
E]Does Not
[Fl10J1
calibration and adjustment of controls.
FINot Observable
E]Not Applicable
C408.2.4
Preliminary commissioning report
ElComplies
[F129]1
completed and certified by registered
ElDoes Not
design professional or approved
FINot Observable
E]Not Applicable
1
submitted within 90 days of system
E]Does Not
FINot Observable
C408.2.5,
� Furnished as -built drawings for
ElComplies
1
electric power systems within 90 days
ElDoes Not
E]Not Applicable
C408.2.5.
!An air and/or hydronic system
ElComplies
3
balancing report is provided for HVAC
E]Does Not
[F14311
systems,
nNot Observable
EINot Applicable
C408.2.5,
Final commissioning report due to
ElComplies
4
building owner within 90 days of
F]Does Not
[F13011
receipt of certificate of occupancy,
nNot Observab I le
E]Not Applicable
C408.3
Lighting systems have been tested to
�Elcomplies
[F13311
ensure proper calibration, adjustment,
E]Does Not
programming, and operation.
FINot Observable
EINot Applicable
Project Title: s7esandAve Report date: 02/07/24
Data filename: page 17m 18
AdditionaXCmmmmnemts/AssmmnpOons:
Project Title: y7ys3rdAve Report date: 02/07/24
Data filename: page 18cf 18