ComCheckCOMcheck Software VerMovp C'ckWeh Envelope Compliance Certificate ( n�( Project Information Energy Code: 2018 IECC Project Title: 379 S 3rd Ave Location: Blair, Nebraska Climate Zone: 5a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Building Area Floor Area 1-Warehouse : Nonresidential 4800 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(.) Perimeter Roof: Attic Roof, Wood joists, [Bldg. Use 1 - Warehouse] 4800 0.0 40.0 0.024 0.027 Floor: Unheated Slab -On -Grade, [Bldg. Use 1 - Warehouse] (b) 280 --- --- 0.730 0.540 EAST Ext, Wall: Wood -Framed, 241n. o.c., [Bldg. Use 1 - Warehouse] 3358 19.0 0.0 0.065 0.064 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Warehouse] 19 --- --- 0.077 0.370 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Warehouse] 19 --- --- 0.077 0.370 Door: Insulated Metal, Swinging, (Bldg, Use 1 - Warehouse] 19 --- --- 0.077 0.370 Door: Insulated Metal, Swinging, [Bldg, Use 1 - Warehouse] 19 --- --- 0.077 0.370 Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1- 168 --- --- 0.100 0.310 Warehouse] Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1- 168 --- --- 0.100 0.310 Warehouse] Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1- 168 --- --- 0.100 0.310 Warehouse] Door: Insulated Metal, Garage door 14% glazing, (Bldg, Use 1- 168 --- 0.100 0.310 Warehouse] Door: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1- 168 --- --- 0.100 0.310 Warehouse] (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Slab -On -Grade proposed and budget U-factors shown in table are F-factors. Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 1 of 18 O- Envelope Compliance Statement Name - Title Signz)ture Date Project Title; 379 S 3rd Ave Report date; 02/07/24 Data filename; Page 2 of 18 8 Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Construction Site: 2018 IECC 379 S 3rd Ave New Construction Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 1-Warehouse Storage: Smaller, Hand -Carried Items 4800 0.62 2976 Total Allowed Watts = 2976 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 1-Warehouse Storage:Smaller, Hand -Carried Items LED: LED Panel 19W: 6 9 19 171 Total Proposed Watts = 171 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist Name - Title Signature Date Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 3 of 18 Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: 2018 IECC 379 S 3rd Ave New Construction 2 (Light industrial area with limited nighttime use (LZ2)) Owner/Agent: Allowed Exterior Lighting Power A Area/Surface Category Designer/Contractor: B C D E Quantity Allowed Tradable Allowed Watts Watts / Wattage (B X C) Driveway 2700 ft2 0,04 Yes 108 Total Tradable Watts (a) = 108 Total Allowed Watts = 108 Total Allowed Supplemental Watts (b) = 400 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces, (b) A supplemental allowance equal to 400 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Driveway (2700 ft2): Tradable Wattage LED: LED Other Fixture Unit 6.5W: 4 4 16 Total Tradable Proposed Watts = 16 Name - Title Sjgc nature Date Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 4 of 18 8 Project Information Energy Code: 2018 IECC Project Title: 379 S 3rd Ave Location: Blair, Nebraska Climate Zone: 5a Project Type: New Construction Construction Site: Owner/Agent: Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Mechanical Systems List Quantity System Type & Description 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity Unknown No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity Unknown No minimum efficiency requirement applies 1 Water Heater: Electric Instantaneous Water Heater, Capacity: 0 gallons No minimum efficiency requirement applies 1 Water Heater: Electric Instantaneous Water Heater, Capacity: 0 gallons No minimum efficiency requirement applies Mechanical Compliance Statement Designer/Contractor: Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit, application. The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version CO fMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist, r Name - Title Si9nature Date Project Title: 379 S 3rd Ave Data filename: Report date: 02/07/24 Page 5 of 18 COMcheck Software VerMo" OuMchec, W Inspection Checklist Energy Code: 2018 IECC Requirements: 7.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided, Section # Plan Review Complies? & Req.lD _ C103.2 ! Plans and/or specifications provide all❑Complies [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable ,envelope and document where ❑Not Applicable exceptions to the standard are claimed, C103.2 Plans, specifications, and/or []Complies [PR2]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the mechanical ❑Not Applicable systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies [PR3]1 calculations provide all information []Does Not with which compliance can be ❑Not Observable :determined for the service water ❑Not Applicable heating systems and equipment and document where exceptions to the ',standard are claimed. Hot water system sized per manufacturer's ;sizing guide. C103,2 !Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not ;with which compliance can be ❑Not Observable determined for the interior lighting Applicable sand electrical systems and equipment❑Not and document where exceptions to ;the standard are claimed. Information provided should include interior lighting power calculations, wattage of ,bulbs and ballasts, transformers and control devices. C103.2 I Plans, specifications, and/or ❑Complies [PR8]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the exterior lighting Applicable and electrical systems and equipment❑Not and document where exceptions to the standard are claimed, Information provided should include exterior ,lighting power calculations, wattage of bulbs and ballasts, transformers and control devices, C402.4,1 ;The vertical fenestration area <= 30 ❑Complies [PR10]1 percent of the gross above -grade wall ❑Does Not area, ❑Not Observable ❑Not Applicable Ccorrawnents/Assumptions 11 High Impact (Tier 1)_12 Medium Impact (Tier 2) _1 3-] Low -Impact (Tier 3) Project Title; 379 5 3rd Ave Data filename: Report date; 02/07/24 Page 6 of 18 # Plan Review & Req ID C402.4.1 The skylight area <= 3 percent of the [PR11]1 gross roof area, Complies'? Comments/Assumptions ElComplies FlDoes Not r]Not observable EINot Applicable C402.4.2 In enclosed spaces > 2,500 ft2 ElComplies [PR14]1 directly under a roof with ceiling E]Does Not heights >15 ft. and used as an office, FINot observable ;lobby, atrium, concourse, corridor, E]Not Applicable ,storage, gymnasium/exercise center, � convention center, automotive �service, manufacturing, non - !refrigerated warehouse, retail store, !distribution/sorting area, 'transportation, or workshop, the �following requirements apply: (a) the daylight zone under skylights is > = half the floor area; (b) the skylight area to daylight zone is >= 3 percent 'with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. C406 'Plans, specifications, and/or ElComplies Requirement will be met. [PR9]1 calculations provide all information E]Does Not ;with which compliance can be nNot observable determined for the additional energy E]Not Applicable efficiency package options. Additional Comments/Assumptions: FiTHi- J�=2Medk�mnm gh Impact (Tier 1) act (Tier 2) 3 Low Impact (Tier 3) Project Title, 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 7 of 18 Se c'ion # Footing / Foundation inspection complies'? Comments/Assumptions C303.2 Slab edge insulation installed per ElComplies [F0412 manufacturer's instructions, InDoes Not nNot observable E]Not Applicable C303.2.1 Exterior insulation protected against OComplies [F0611 damage, sunlight, moisture, wind, FlDoes Not �landscaping and equipment nNot Observable :maintenance activities. [:]Not Appl !cable C105 :Installed slab -on -grade insulation type ElComplies See the Envelope Assemblies table for values. [F03]2 and R-value consistent with insulation E]Does Not ,specifications reported in plans and FINot Observable COMcheck reports. EINot Applicable C402.2.4 Slab edge insulation depth/length. Dcomplies See the Envelope Assemblies table for values. [F07]2 Slab insulation extending away from E]Does Not building is covered by pavement or F-INot Observable >= 10 inches of soil. C403,12.2 Snow/ice melting system and freeze OComplies I I protection systems have sensors and E]Does Not C403.12.3 'controls configured to limit service for PNot Observable [F09]3 pavement temperature and outdoor ONot Applicable temperature. future connection to Add|t]mnaUCsnmmoemts/Aymunnpboms: _LL��igh impact (Tier 1_ F2]Mediurn Impact (Tier 2) —3] Low ct (Tier Project Title: a7sS3rdAve Report date' 02/07/24 Data filename: Page 8m 18 & Req . I DT FINot Observable EINot Applicable C303.1.3 !,Fenestration products are certified as ElComplies [FR13]1 �to performance labels or certificates E]Does Not provided. nNot Observable E]Not Applicable C402.4.3 'Vertical fenestration SHGC value. OComplies See the Envelope Assemblies table for values. �nNot Observable E]Not Applicable C402.4.3, Installed vertical fenestration LI-factor ElComplies See the Envelope Assemblies table for values. C402.4.3. ;and SHGC consistent with label F]Does Not 4 specifications and as reported in plans nNot Observable E]Not Applicable C402.5.1. 'The building envelope contains a ElComplies 2.1 continuous air barrier that is sealed in ElDoes Not [FR1911 an approved manner and material nNot Observable E]Not Applicable barrier penetrations are sealed in an ;approved manner. C402.5.2, Factory -built fenestration and doors ElComplies C402.5.4 are labeled as meeting air leakage E]Does Not FR1813 requirements. nNot Observable E]Not Applicable C402.5.7 �Vestibules are installed on all building ElComplies [FR17]3 entrances. Doors have self -closing ElDoes Not devices. F]Not Observable EINot Applicable Additioma|Comnmnemta/Assmmmpdmns: F1THIgh Impact (Tier Project Title: a7ssandAve Report date: 02/07/24 Data filename: page 9m 18 Section # Plumbing Rough -in Inspection Complies'? Comments/Assumptions R .113 �1__ _§ C404.5, Heated water supply piping conforms ElComplies C404.5.1, 'to pipe length and volume FIDoes Not C404.5.2 :requirements. Refer to section details. nNot Observable [PL6]3 E]Not Applicable C404.6.3 Pumps that circulate water between a ElComplies [PL7]3 'heater and storage tank have controls E]Does Not that limit operation from startup to FINot Observable <= 5 minutes after end of heating EINot Applicable cycle, C404.7 Demand recirculation water systems ElComplies [PI_8]3 have controls that start the pump E]Does Not upon receiving a signal from the E]Not Observable, action of a user of a fixture or -EINot Applicable appliance and limits the temperature of the water entering the cold -water !piping to 104°F. Additional Comments/Assumptions: 01High Impact (Tieri) 2]Medium 31 Low Impact (Tier 3) --------- Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 10 of 18 Sectiokt # Mechanical Rough in Inspection Corriplies:3 orraments/Assumptions C402,2,6 !Thermally ineffective panel surfaces of❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3,5, ❑Not Observable ❑Not Applicable C402,5.5, Stair and elevator shaft vents have ❑Complies C403,2,4, motorized dampers that automatically !❑Does Not 3 close, Refernece section C403.7J for ❑Not Observable [ME3]3 operational details, ❑Not Applicable C403,7,7 ;Outdoor air and exhaust systems have ❑Complies [ME58]3 ' motorized dampers that automatically❑Does Not shut when not in use and meet ❑Not Observable maximum leakage rates. Check gravity dampers where allowed, ❑Not Applicable Reference section language for operational details, C403,11,3,I HVAC piping insulation insulated in ❑Complies [ME61]2< accordance with Table C403.11.3. ❑Does Not Insulation exposed to weather is ❑Not Observable protected from damage and is provided with shielding from solar ❑Not Applicable radiation. C403,8.1 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values, [ME65]3 conditions do not exceed allowable ❑Does Not 'fan system motor nameplate hp or fan ❑Not Observable system bhp, ❑Not Applicable C4018,3 ' Fans have efficiency grade (FEG) >= ❑Complies [ME117]2 67. The total efficiency of the fan at ❑Does Not the design point of operation <= 15% ❑Not Observable of maximum total efficiency of the ❑Not Applicable fan. C403.12.1 ! Systems that heat outside the building'❑Complies [ME71]2-``" envelope are radiant heat systems '❑Does Not ,controlled by an occupancy sensing ❑Not Observable device or timer switch. ❑Not Applicable C403,2.2 ;Natural or mechanical ventilation is ❑Complies [ME59]1 provided in accordance with ❑Does Not International Mechanical Code ❑Not Observable Chapter 4, Mechanical ventilation has capability to reduce outdoor air supply ❑Not Applicable to minimum per IMC Chapter 4. C403J,1 ;Demand control ventilation provided ❑Complies [ME59]1 for spaces >500 ft2 and >25 ❑Does Not people/1000 ft2 occupant density and❑Not Observable served by systems with air side economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm, C403.7,2 Enclosed parking garage ventilation ❑Complies [ME115]3 has automatic contaminant detection ❑Does Not and capacity to stage or modulate ❑Not Observable fans to 50% or less of design capacity. ❑Not Applicable C403,7,6 HVAC systems serving guestrooms in❑Complies [ME141]3 'Group R-1 buildings with > 50 ❑Does Not guestrooms: Each guestroom is ❑Not Observable provided with controls that ❑Not Applicable automatically manage temperature ,setpoint and ventilation (see sections C403J.6,1 and C403,7.6.2), 1 High Impact (Tier i) Medium Impact (Tier 2)—� 3 ]Low Impact (Tier 3) Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 11 of 18 Section # f�echanical Rough -In Inspeetion Complies: Comments/Assumptions & Req.113 C403.7.4 I Exhaust air energy recovery on ❑Complies [ME57]1 !systems meeting Table C403.7.4(1) ❑Does Not ,and C403,7.4(2). ❑Not Observable ❑Not Applicable C403.7,5 ',Kitchen exhaust systems comply with❑Complies [ME116]3 'replacement air and conditioned I[]Does Not ,supply air limitations, and satisfy hood ❑Not Observable rating requirements and maximum ❑Not Applicable exhaust rate criteria. C403.11.1 HVAC ducts and plenums insulated in ❑Complies accordance with C403.11,1 and ❑Does Not C403.11.2 constructed in accordance with ❑ Not Observable [ME60]2 C403,11,2, verification may need to ❑Not Applicable occur during Foundation Inspection. C403.4.1. Heating for vestibules and air curtains ❑Complies 4 with integral heating include ❑Does Not [ME63]2 automatic controls that shut off the ❑Not Observable heating system when outdoor air ❑Not Applicable temperatures > 45F, Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint >= 80F. C408,2.2. :Air outlets and zone terminal devices ❑Complies 1 have means for air balancing. ❑Does Not [ME53]3 ❑Not Observable ❑Not Applicable C403.5, Refrigerated display cases, walk-in ❑Complies C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote ❑Not Observable [ME123]3 ;condensers not located in a ❑Not Applicable condensing unit, have fan -powered condensers that comply with Sections I C403.5.1 and refrigeration compressor' systems that comply with C403,5,2,. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 ;Low Impact (Tier 3) Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 12 of 18 section Rough -In Electrical # Rough -in Electrical Inspection Complies? Comments/Assumptions & Reci.113 C405.2.2. Spaces required to have light- Elcomplies 2 reduction controls have a manual ElDoes Not [EL22]1 !control that allows the occupant to FJNot Observable ( reduce the connected lighting load in E]Not Applicable ;a reasonably uniform illumination pattern >= 50 percent, C405.2.1, Occupancy sensors installed in ElComplies C405.2.1, classrooms/lecture/training rooms, E]Does Not 1 conference/meeting/multi purpose FINot Observable [EL18]1 rooms, copy/print rooms, �lounges/breakrooms, enclosed offices, E]Not Applicable open plan office areas, restrooms, storage rooms, locker rooms, ,warehouse storage areas, and other :spaces <= 300 sqft that are enclosed by floor -to -ceiling height partitions. Reference section language lC405.2.1.2 for control function in warehouses and section C405,213 !for open plan office spaces. C405.2.1. Occupancy sensors control function in ElComplies 2 warehouses: In warehouses, the DDoes Not [EL19]1 !!lighting in alsleways and open areas is FI Not Observable controlled with occupant sensors that � ONot Applicable automatically reduce lighting power by 50% or more when the areas are 'unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. Occupant sensor control function in ElComplies 3 open plan office areas: Occupant �RDoes Not [EL20]1 ,sensor controls in open office spaces FINot Observable 300 sq.ft. have controls 1) configured so that general lighting can E]Not Applicable be controlled separately in control .zones with floor areas < = 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones ,within 20 minutes after all occupants ;have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of �the full zone general lighting power ;within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected, C405.2.2, Each area not served by occupancy ElComplies C405.2.2. sensors (per C405,2, 1) have time- E]Does Not 1, switch controls and functions detailedF-lNot 'in Observable C405.2.2. sections C405.2.2.1 and C405.2,2.2., E] Not Applicable 2 [EL21]2 3 - 110 - _21— — - - --w Impact (Tier 3) _ Medium Impact (Tier 2) I 11 High Impact (Tier 14__7 Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 13 of 18 Section r # Rough -in Electrical inspection Complies"? I Cornments/Assumptions & Req.lt3 ) C405.2.3, ",Daylight zones provided with ❑Complies C405.2.3. ! individual controls that control the ❑Does Not 1, lights independent of general area ❑Not Observable C405.2.3. ;lighting. See code section C405,2,3 ❑Not Applicable 2 Daylight -responsive controls for [EL23]2 applicable spaces, C405.23,1 Daylight, responsive control function and section C405,23.2 Sidelit zone, C405,2.4 Separate lighting control devices for ❑Complies [EL26]1 uses installed per approved ❑Does Not ,specific lighting plans. ❑Not Observable ❑Not Applicable _ C405.2,4 'Additional interior lighting power ❑Complies [EL27]1 allowed for special functions per the ❑Does Not ,approved lighting plans and is ;automatically controlled and ❑Not Observable separated from general lighting, ❑Not Applicable C405,2.5 Manual controls required by the ❑Complies [EL28]na0 energy code are in a location with ❑Does Not 'ready access to occupants and located where the controlled lights are❑Not Observable visible, or identify the area served and❑Not Applicable their status. C405,2.6 :Automatic lighting controls for exterior'❑Complies [EL30]na0 lighting installed. Controls will be ❑Does Not daylight controlled, set based on ❑Not Observable business operation time -of -day, or reduce connected lighting > 30% ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face, ❑Does Not ❑Not Observable ❑Not Applicable C405.6 ` Low -voltage dry -type distribution ❑Complies Exception: Requirement does not apply, [EL26]2 electric transformers meet the ❑Does Not minimum efficiency requirements of ❑Not Observable ..'..Table C405.6, ❑Not Applicable C405.7 Electric motors meet the minimum ❑Complies Exception: Requirement does not apply. [EL2712 efficiency requirements of Tables ❑Does Not C405.7(1) through C405,7(4), Observable Efficiency verified through certification'❑Not ❑Not Applicable under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist), C405;8,2, 'Escalators and moving walks comply ❑Complies Exception: Requirement does not apply, C405,8.2. :with ASME A17,1/CSA B44 and have ❑Does Not 1 automatic controls configured to Not Observable [EL28]2 reduce speed to the minimum permitted speed in accordance with ❑Not Applicable pp ASME A17.1/CSA B44 or applicable local code when not conveying passengers. _ C405.9_ Total voltage drop across the ❑Complies Exception: Requirement does not apply, [EL29]2 combination of feeders and branch ❑Does Not circuits <= 5%. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 12 Medium Impact (Tier 2) �3 Low Impact (Tier 3) Project Title: 379 S 3rd Ave Report date; 02/07/24 Data filename: Page 14 of 18 Section # FInsulation Inspection Complies? I Comments/Assumptions & Req.ID _ _ C303,1 Roof insulation installed per ❑Complies [IN3]1 : manufacturer's instructions. Blown or❑Does Not ;poured loose -fill insulation is installed❑Not Observable' ;only where the roof slope is <=3 in 12 ❑Not Applicable J C402.2.1 ;Insulation installed on a suspended ❑Complies [IN20]1 ceiling having ceiling tiles is not being❑Does Not ;specified for roor/ceiling assemblies, ❑Not Observable .Continuous insulation board installed in 2 or more layers with edge joints ❑Not Applicable offset between layers. C303,1 (Building envelope insulation is labeled❑Complies [IN10]z with R-value or insulation certificate ❑Does Not providing R-value and other relevant ❑Not Observable' data. ❑Not Applicable _ C303.2 ,Above -grade wall insulation installed ❑Complies [IN7]1 per manufacturer's instructions, ❑Does Not ❑Not Observable' ❑Not Applicable _ C105 Installed above -grade wall insulation ❑Complies See the Envelope Assemblies table for values. [IN6]1 type and R-value consistent with ❑Does Not insulation specifications reported in ❑Not Observable I plans and COMcheck reports, ❑Not Applicable C402.2.3 '', Installed floor Insulation type and R- ❑Complies See the Envelope Assemblies table for values, [IN8]2 value consistent with insulation ❑Does Not ;specifications reported in plans and ❑Not Observable COMcheck reports, ❑Not Applicable C402.2,6 Radiant panels and associated ❑Complies [IN18]3 components, designed for heat ❑Does Not transfer from the panel surfaces to the,❑Not Observable occupants or indoor space are ❑Not Applicable insulated with a minimum of R-3,5, C105 I Installed roof insulation type and R- ❑Complies See the Envelope Assemblies table for values. [IN2]1 value consistent with insulation ❑Does Not ,specifications reported in plans and ❑Not Observable �COMcheck reports. For some ceiling 'systems, verification may need to ❑Not Applicable occur during Framing Inspection, C402.5,1. ;All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed,❑Does Not (IN1]1 caulked, gasketed, weather stripped ❑Not Observable or wrapped with moisture vapor - ,permeable wrapping material to ❑Not Applicable ;minimize air leakage, Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 Low Impact (Tier 3) Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 15 of 18 . section # Final inspection Complies Comments/Assumptions & Req.i® _ C303.3, !Furnished O&M instructions for ❑Complies C408,2.5. I systems and equipment to the ❑Does Not 2 [F117]3 building owner or designated representative. ❑Not Observable' ❑Not Applicable C303.3, ' Furnished O&M manuals for HVAC ❑Complies C408,2,5. isystems within 90 days of system ❑Does Not 3 [F18]3 acceptance. ❑Not Observable ❑Not Applicable — C402.5.6 ' Weatherseals installed on all loading ❑Complies [F137]1 dock cargo door openings and provide'❑Does Not direct contact along the top and sides ❑Not Observable of vehicles parked in the doorway, ❑Not Applicable _ C402.5.8 Recessed luminaires in thermal ❑Complies [F126]3 envelope to limit infiltration and be IC❑Does Not rated and labeled. Seal between ,❑Not Observable' interior finish and luminaire housing, ❑Not Applicable C403.2,2 HVAC systems and equipment ❑Complies [F127]3 capacity does not exceed calculated ❑Does Not loads, ❑Not Observable ❑Not Applicable C403.2.4. ,Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device ❑Not Observable per installed' humidification/dehumidification ❑Not Applicable system. C403.4.1. '.Thermostatic controls have a 5 °F _ ❑Complies 2 'deadband, ❑Does Not (F138]3 ❑Not Observable ❑Not Applicable C403.2.4. 'Temperature controls have setpoint ❑Complies 1.3 overlap restrictions. []Does Not [F120]3 ❑Not Observable ❑Not Applicable C403.2,4. Each zone equipped with setback ❑Complies 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ❑Not Observable ]Not Applicable C403.2,4, (Automatic Controls: Setback to 55°F ❑Complies 2.1, (heat) and 85°F (cool); 7-day clock,, 2- ❑Does Not C403.2.4, hour occupant override, 10-hour ❑Not Observable 2.2 [F140]3 backup ❑Not Applicable C404.3 :Heat traps installed on supply and ❑Complies [F111]3 discharge piping of non -circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable C404.4. All piping insulated in accordance with ❑Complies [F125)2 section details and Table C403,11,3. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) �3 Low Impact (Tier 3) Project Title: 379 S 3rd Ave Report date: 02/07/24 Data filename: Page 16 of 18 # Final Inspection Complies? Comments/Assumptions C405.4.1 Interior installed lamp and fixture ElComplies See the Interior Lighting fixture schedule for values. [FI1811 lighting power is consistent with what E]Does Not ,is shown on the approved lighting FlNot Observable plans, demonstrating proposed watts EINot Applicable are less than or equal to allowed C405.5.1 Exterior lighting power is consistent [komplies See the Exterior Lighting fixture schedule for values. [FI1911 :with what is shown on the approved E]Does Not ,lighting plans, demonstrating � proposed watts are less than or equal FINot Observable '!to allowed watts. 'E]Not Applicable C408.1.1 Building operations and maintenance ElComplies Requirement will be met, F15711 documents will be provided to the DDoes Not owner. Documents will cover nNot Observable manufacturers' information, ;specifications, programming E]Not Applicable procedures and means of illustrating to owner how building, equipment and ;systems are intended to be installed, � maintained, and operated. C408.2.1 !Commissioning plan developed by ElComplies [F12811 ;registered design professional or FIDoes Not :approved agency. FJNot Observable C408.2.3. 'HVAC equipment has been tested to ElComplies 1 :ensure proper operation, ;,[]Does Not FlNot Observable E]Not Applicable C408.2.3. 'HVAC control systems have been ElComplies 2 �tested to ensure proper operation, E]Does Not [Fl10J1 calibration and adjustment of controls. FINot Observable E]Not Applicable C408.2.4 Preliminary commissioning report ElComplies [F129]1 completed and certified by registered ElDoes Not design professional or approved FINot Observable E]Not Applicable 1 submitted within 90 days of system E]Does Not FINot Observable C408.2.5, � Furnished as -built drawings for ElComplies 1 electric power systems within 90 days ElDoes Not E]Not Applicable C408.2.5. !An air and/or hydronic system ElComplies 3 balancing report is provided for HVAC E]Does Not [F14311 systems, nNot Observable EINot Applicable C408.2.5, Final commissioning report due to ElComplies 4 building owner within 90 days of F]Does Not [F13011 receipt of certificate of occupancy, nNot Observab I le E]Not Applicable C408.3 Lighting systems have been tested to �Elcomplies [F13311 ensure proper calibration, adjustment, E]Does Not programming, and operation. FINot Observable EINot Applicable Project Title: s7esandAve Report date: 02/07/24 Data filename: page 17m 18 AdditionaXCmmmmnemts/AssmmnpOons: Project Title: y7ys3rdAve Report date: 02/07/24 Data filename: page 18cf 18