St Fire Marshal Code ReviewIx. NEBRASKA STATE FIRE MARSHAL PLANS DIVISION N FPX Code Review 8/21/2023 1 Code Review Number: 08075-23 Submitting Party Location Jeremy Beckenhauer The Healthy Human Outdoor Concepts 1659 Washington St 1648 South Street Blair 68008 Blair, NE 68008- Your items have been reviewed for compliance with the Nebraska State Fire Marshal Act. Building - Final Plans REMARKS: IIGL Review applies to a single story 23' x 98' modification of a three story building as shown only. The on -site inspector shall determine compliance of existing conditions beyond the scope of this code review. Occupancy Type - New Mixed Class C Mercantile (36) & Business (38) Occupancy Sale Estimated Occupant Load - 26 @ 30 sq. ft. per person Codes Referenced - 2012 NFPA 1 / 2012 Life Safety Code (LSC) / 2009 NFPA 241 Fire Protection Features Provided — Fire Extinguishers Site Plan Submitted? - NO (on -site inspector shall determine compliance of existing conditions) Construction Type — Unknown NOTES: Plans for the basement and second levels have not been submitted for review and the on -site inspector shall determine compliance of existing conditions beyond the scope of this code review. This code review does not determine compliance with the State of Nebraska Accessibility Guidelines. This determination shall be done by the local jurisdiction in which the project is located. Plans that do not bear the seal of a State Registered Engineer/Architect may be subject to review by The Board of Engineers & Architects. For questions, concerns, or requirements please contact The Board of Engineers & Architects at (402) 471-2021. 1. (If Bldg. Remains Occupied) Approved egress shall be maintained from the existing building throughout and thereafter construction. Areas under construction shall be separated from the existing building by one -hour fire rated construction. NFPA 241, 8.6.2 2. Exits shall terminate directly at a public way or at an exterior exit discharge. A sidewalk that is free of obstructions or impediments shall be provided to a public way. LSC 36/38.2.7, 7.7.1 (Amended) 3. Illumination in accordance with 7.8 is required for designated stairs, aisles, corridors, ramps, escalators, and passageways leading to a public way. LSC 36/38.2.8, 7.8.1 4. Exits shall be marked by an approved sign readily visible from any direction of exit access. LSC 36/38.2.10, 7.10.1.2 Page I of 2 PLEASE CONTACT OFFICE INDICATED BELOW FOR A FINAL INSPECTION. FINAL APPROVAL IS REQUIRED PRIOR TO OCCUPANCY OR USE SIGNED. Reviewed By: John Dodds 246 S 14th St Contact for Inspection: District A 246 S 14th St Lincoln, NE 68508-1804 john.dodds@nebraska.gov 402-471-9465 Lincoln, NE 68508-1804 402-395-2164 5. RE: Mechanical Room - Hazardous areas used for general storage, janitor closets, boiler or furnace rooms, and maintenance shops, shall be enclosed and/or separated by a fire barrier that has a 1-hour fire resistance rating and shall include a 45 minute rated self -closing, positive latching fire door. LSC 38.3.2.1, 8.7.1 6. Interior wall and ceiling finish material shall be Class A, Class B, or Class C throughout. LSC 36/38.3.3.2 Page 2 of 2 PLEASE CONTACT OFFICE INDICATED BELOW FOR A FINAL INSPECTION. FINAL APPROVAL IS REQUIRED PRIOR TO OCCUPANCY OR USE SIGNED. Reviewed By: John Dodds 246 S 14th St Contact for Inspection: District A 246 S 14th St Lincoln, NE 68508-1804 john.dodds@nebraska.gov 402-471-9465 Lincoln, NE 68508-1804 402-395-2164