ResCheckCGenerated �J( Compliance Certificate Project Blair Caskey 2 Energy Code: 2018 IECC Location: Blair, Nebraska Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,200 ft2 Glazing Area 8% Climate Zone: 5 (6506 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Compliance: 21.7% Better Than Code Maximum UA: 207 Your UA: 162 The % Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in ttEScheck. Each slab -on -grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements, Envelope Assemblies Ceiling: Raised or Energy Truss 1,200 60.0 55.0 0.009 0.026 11 31 Wall: Structural Insulated Panels 1,260 27.0 0.040 0.060 45 67 Door: Solid Door (under 50%,glazing) 54 0,350 0.300 19 16 Window: Vinyl Frame 83 0.480 0,300 40 25 Basement Wall: Solid Concrete or Masonry Wall height: 9.0' 1,260 15.0 14.0 0.030 0.050 37 62 Depth below grade: 8.0' Insulation depth: 9.0' Window: Vinyl Frame 20 0,480 0.300 10 6 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application, The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version RE5theckWeb and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. r,t / Name - Title Signature Date Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename: Page 1 of 9 SoftwareREScheck Version Inspection Checklist Energy Code: 2018 IECC Requirements: 0,0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) _ 3Low Impact (Tier 3) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename: Page 2 of 9 Section # _ �A�� Foundation inspection F�ians Verified Value Field Verified Value 0�mplies2 Oomments/Assumptions & Req.11D 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value. Where interiorR- R- ❑Does Not table for values, j insulation is used, verification T❑Not Observable may need to occur during ❑Not Applicable Insulation Inspection, Not required in warm -humid locations in Climate Zone 3. _ 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not manufacturer's instructions, ❑Not Observable ❑Not Applicable 402.2.9 ;Conditioned basement wall ft �ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall, ❑Not Observable ❑Not Applicable 303,2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a [:]Not Observable ,minimum of 6 in. below grade. ❑Not Applicable 4019 ;Snow- and ice -melting system ❑Complies [FO12]2 controls installed. ❑Does Not . ❑Not Observable '❑Not Applicable Additional Comments/Assumptions: 1 lHigh Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename; Page 3 of 9 Plans V,01 �ied 9 / Rough -in Inspetion] Field Verified V C mplies? Comments/Assumptions 402.3.4 E]Does Not table for values, FINot Observable E]Not Applicable 402.1.1, Glazing LI-factor (area -weighted U- U_ ElComplies See the Envelope Assemblies 402.3.1, average), E]Does Not table for values. [FR411 are determined in accordance F]Does Not 'with the NFRC test procedure or E]Not Observable ;taken from the default table, E]Not Applicable 402.4.1.1 Air barrier and thermal barrier l7lComplies [FR23]1 'Installed per manufacturer's E]Does Not [:]Not Observable E]Not Applicable 402.4.3 Fenestration that is not site built OComplies [FR2011 'is listed and labeled as meeting F]Does Not F]Not Observable or has infiltration rates per NFRC 'E]Not Applicable 400 that do not exceed code 402.4.5 IC -rated recessed lighting fixtures 1771complies [FR16]2 :sealed at housing/interior finish FIDoes Not and labeled to indicate :52.0 cfm E]Not Observable 'leakage at 75 Pa, E]Not Applicable 403.3.1 Supply and return ducts in attics ElComplies E]Not Observable R-6 where < 3 inches. Supply and E]Not Applicable return ducts in other portions of the building insulated >= R-6 for 403.3.2 !Ducts, air handlers and filter ElComplies FR1311 boxes are sealed with E]Does Not �joints/seams compliant with E]Not Observable '.International Mechanical Code or nNot Applicable International Residential Code, as 403.3.5 Building cavities are not used as ElComplies [FR15]3 ducts or plenums. F]Does Not E]Not Observable E]Not Applicable 1 2 1 Medium Impact (Tier 3JLow Impact (Tier 3" Project Title: Blair Caskey2 Report date: 08/07/23 Datafi|mname: Page 4nf 9 # Framing / Rough -in inspection plans Verified ^ Fieid Verified Comments/Assumptions Vale ValueComplies? 403.3.7 !Ducts declared to be within the ❑Complies [FR28]3 'conditioned space are either 1) ❑Does Not :completely within the continuous ❑Not Observable air barrier and within the building ❑Not Applicable thermal envelope, 2) buried within ceiling insulation in accordance with Section R403,3,6 and the air handler is located completely within the continuous air barrier and within ;the building thermal envelope land the duct leakage is <= 1.5 t cfm / 100 square feet of ;conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R-value, less the R- value of the insulation on the 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- ❑Not Observable 3 ❑Not Applicable 403.41 ;Protection of insulation on HVAC ❑Complies [FR24]1 j piping. +❑Does Not ❑Not Observable ❑Not Applicable 4015.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not � ❑Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers are u'❑Complies [FR19]2 'Installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) I Project Title; Blair Caskey 2 Report date; 08/07/23 Data filename: Page 5 of 9 # Insulation Inspection Pians Vrl�ied Flo Complies? Comm ents/Assu mptions 303.1 :All installed insulation is labeled nComplies [IN13]2 :or the installed R-values E]Does Not EINot Observable EINot Applicable 4021.1, �Wall insulation R-value, If this is a R- R- "ElComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the F-1 Wood Wood OlDoes Not table for values, 402.2.6 wall insulation on the wall [IN311 :exterior, the exterior insulation :requirement applies (FR10). ' E] Steel E] Steel E]Not Applicable 303.2 Wall insulation is installed per ElComplies [IN411 manufacturer's instructions, E]Does Not E]Not Observable E]Not Applicable AddHdamaUCmmmmmamts/Asamnmpdmms: 1 1 High Impact (Tier 1) F2 Medium Impact (Tier 2) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename: Page bof 9 Section # Final Inspection Provisions Mans Verified � Value Field Verified complies? Comments/Assumptions & Req.I® L - 402.1.1, Ceiling insulation R-value. - R- R- - ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values, 402,2,2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [Fill' ❑ Not Applicable 303.1.1.1, (Ceiling insulation installed per T ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every ❑Not Observable 300 ft2. ❑Not Applicable 402.2.3 'Vented attics with air permeable ❑Complies [F122]2 I insulation include baffle adjacent ❑Does Not 'to soffit and eave vents that ❑Not Observable extends over insulation, ❑Not Applicable 402.2.4 'Attic access hatch and door R- R ❑Complies [F1311 Jnsulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 ',Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F11711 ; ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 'Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 � determine air leakage with ft2 ft2 ❑Does Not either: Rough -in test: Total ❑Not Observable ,leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g, across the system including ;the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total ;leakage measured with a pressure differential of 0,1 inch w.g, across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of <=4 cfm/100 cfm/100 ❑Complies [F1411 !cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough -in ❑Not Applicable :tests, verification may need to occur during Framing Inspection. 403,3,2,1 ,Air handler leakage designated ❑Complies [F124]1 by manufacturer at <=2% of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 :Programmable thermostats ❑Complies [F19]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to ❑Not Applicable code specifications. 403.1.2 Heat pump thermostat installed❑Complies [F110]2 on heat pumps, ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [F111]2 systems have automatic or '❑Does Not 'accessible manual controls, ❑Not Observable ❑Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename; Page 7 of 9 Section # Final Inspection Provisions Plans Verified Value Feld Verified Value Corraplies7 Comments/Assumptions & Req.ID 403,6.1 All mechanical ventilation system r ❑Complies [FI25]2 ;fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable ,and airflow limits per Table ❑Not Applicable R403.6.1, 403,2 Hot water boilers supplying heat ❑Complies [F126]2 through one- or two -pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water ❑Not Applicable temperature based on outdoor temperature. 403.5.1.1 : Heated water circulation systems ❑Complies [F12812 ' have a circulation pump. The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply []Not Applicable pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set -point temperature and no demand for hot water exists. 403.5.1.2 )' Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Complies [F13012 systems have controls that ❑Does Not manage operation of the pump ❑Not Observable and limit the temperature of the ❑Not Applicable water entering the cold water piping to <= 104°F. _ 403.5.4 .` Drain water heat recovery units ❑Complies [F1311*2 tested in accordance with CSA ❑Does Not B55,1. Potable water -side ❑Not Observable pressure loss of drain water heat ❑Not Applicable recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers, 404.1 90% or more of permanent ❑Complies [F1611 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123)3 no continuous pilot light, ❑Does Not ❑Not Observable ❑Not Applicable 401.3 'Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) 1-2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename: Page 8 of 9 Secian Mans Verified Freld Verified # !Final Inspection Provisions Value Valur Complies? Camments/Asstamptians & Req.ID 303,3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) Project Title: Blair Caskey 2 Report date: 08/07/23 Data filename; Page 9 of 9 2018 IECC Energy L�(j Effidency Certificate Above -Grade Wall 27.00 Below -Grade Wall 29.00 Floor 0.00 Ceiling / Roof 115.00 Ductwork (unconditioned spaces): Window 0.48 Door 0.35 Heating System: Cooling System: Water Heater: Name: Date: ,r f Comments