St Fire Marshal Code Review�gTIFr� NEBRASKA STATE FIRE MARSHAL L �� PLANS DIVISION 1 NFL►• - Code Review 8/17/2021 1 Code Review Number: 07126-21 Submitting Party Location Tim Mashek Walmart #4568 Service First Fire Sprinkler 1882 Holly St 2212 East 39th Street North Blair, NE 68008 Sioux Falls, SD 57104- Your items have been reviewed for compliance with the Nebraska State Fire Marshal Act. Shop Drawings -Sprinkler System REMARKS: Review applies to a sprinkler system remodel as shown only. The on -site inspector shall determine compliance of existing conditions beyond the scope of this code review. Occupancy Type - New Mercantile Occupancy Codes Referenced - 2010 NFPA 13 / 2010 NFPA 24 / 2011 NFPA 25 Fire Protection Features Provided — Total Sprinkler Construction Type - V (000) 1. Where a required fire protection system is out of service for more than 10 hours in a 24-hour period, the impairment coordinator shall arrange for one of the following: (a) Evacuation of the building or portion of the building affected by the system out of service. (b) An approved fire watch. (c) Establishment of a temporary water supply. (d) Establishment and implementation of an approved program to eliminate potential ignition sources and limit the amount of fuel available to the fire. NFPA 25 15.5.2(4) 2. All piping and attached appurtenances subjected to system working pressure shall be hydrostatically tested at 200 psi (13.8 bar) or 50 psi (3.5 bar) in excess of the system working pressure, whichever is greater, and shall maintain that pressure without loss for 2 hours. NFPA 13 24.2.1 3. After the systems have been installed, the completed Contractor's Material and Test Certificates for Aboveground and Underground piping shall be provided to and accepted by the State Fire Marshal to receive final approval. This must be done before the system is put into service. Title 153 Chapter 19 003.05 4. In order for the State Fire Marshal's Office to create a record of each system for tracking purposes, every water -based fire protection system shall have a separate and distinct serial identification number. Each system shall be tagged with a seal issued by the State Fire Marshal's Office. The seal shall be placed in a highly visible location. Each of the following devices must bear a separate identification tag and corresponding serial number. Title 153 chapter 19 003.07 (riser tags may be purchased at www.fscan.org) Page 1 of 1 PLEASE CONTACT OFFICE INDICATED BELOW FOR A FINAL INSPECTION. �_fI�NL APPROVAL IS REQUIRED PRIOR TO OCCUPANCY OR USE SIGNED: Reviewed By: Kaylan Lovgren 246 S 14th St Lincoln, NE 68508-1804 402-560-0500 Contact for Inspection: District A 246 S 14th St Lincoln, NE 68508-1804 402-471-2590