ResCheckC�(REScheck Software Version 4.6.4
J Compliance Certificate
Project Spec 1
Energy Code:
2015 IECC
15.0 15.0 0.034
58
Location:
Blair, Nebraska
0.190
3
Construction Type:
Single-family
0.190
3
Project Type:
New Construction
0.190
Conditioned Floor Area:
0 ft2
16
0.190
Glazing Area
11%
16
0.190
Climate Zone:
5 (6506 HDD)
16
0.190
Permit Date:
4/26/2021
16
0.190
Permit Number:
rn-2021-00075
16
0.190
Construction Site:
Window 1 copy 8: Vinyl/Fiberglass Frame:Triple Pane with Low -E
Owner/Agent:
Designer/Contractor:
blair, NE 68008
Window 1 copy 9: Vinyl/Fiberglass Frame:Triple Pane with Low -E
Dale Hansen
Dale Hansen
3
Window 1 copy 10: Vinyl/Fiberglass Frame:Triple Pane with Low -E
Tyler Construction
Tyler Construction
3
Window 1 copy 11: Vinyl/Fiberglass Frame:Triple Pane with Low,E
14771 county road 20
14771 county road 20
3
Window 1 copy 12: Vinyl/Fiberglass Frame:Triple Pane with Low -E
blair, NE 68008
Blair, NE 68008
3
Window 1 copy 13: Vinyl/Fiberglass Frame:Triple Pane with Low -E
402-510-9180
402-510-9180
3
Project Title: spec 1
tylerconstructionlic@yahoo.com
tylerconstructionlic@yahoo.com
Compliance: 30.41/6 Better Than Code Maximum UA: 247 Your UA: 172
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Enyalope Assemblies
Wall 1: Wood Frame, 16" D.C.
2,000
15.0 15.0 0.034
58
Window 1: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 1: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 2: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 3: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 4: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 5: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 6-Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 7: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 8: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 9: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 10: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 11: Vinyl/Fiberglass Frame:Triple Pane with Low,E
16
0.190
3
Window 1 copy 12: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Window 1 copy 13: Vinyl/Fiberglass Frame:Triple Pane with Low -E
16
0.190
3
Project Title: spec 1
Report date: 06/08/21
Data filename: Untitled.rxl
Page 1
of10
Door 1: Solid 21 0.120 3
Door 1 copy 1: Solid 21 0.120 3
Door 1 copy 2: Solid 21 0.120 3
Ceiling 1: Raised or Energy Truss 2,048 0.0 30.0 0.031 63
Compliance Statement; The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The propose building has een designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory re it m is liste n the REScheck Inspection Checklist. (�
Dale 9� `
Name - Title Signature Date
Project Notes:
no address as of current
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 2 of10
REScheck Software Version
C�(J Inspection Checklist
Energy Code: 2015 IECC
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Pre-Inspection/Plan Review
;
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
&'tReq.ID
103.1,
Construction drawings and
❑Complies
❑Does Not
103.2
!documentation demonstrate
[PR111
energy code compliance for the
❑Not Observable
-
building envelope. Thermal
❑Not Applicable
envelope represented on
construction documents.
103.1,
Construction drawings and
❑Complies
103.2,
documentation demonstrate
❑Does Not
403.7
energy code compliance for
❑Not Observable
[PR311
'lighting and mechanical systems.
[]Not Applicable
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1,
Heating and cooling equipment is
_
Heating: Heating:
!❑Complies
403.7
sized per ACCA Manual S based
Btu/hr Btu/hr
❑Does Not
(PR2]2
on loads calculated per ACCA
Cooling: Cooling:
i❑Not Observable
Manual J or other methods
Btu/hr Btu/hr
L7Not Applicable
approved by the code official.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 3 of 10
Section
#
& Req.ID
Foundation Inspection
Complies?
Comments/Assumptions
303.2.1
A protective Covering is installed to
'ElComplies
[F011]2
;protect exposed exterior insulation
ElDoes Not
.t
and extends a minimum of 6 in, below,
:nNot Observable=
grade,
�EINot Applicable
403.9
Snow- and ice -melting system controls
`ElComplies
[FO12]2
installed.
C]Does Not
;Not Observable
ENot Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxi Page 4 of 10
Section
#
Framing / Rough -in inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.iD
402.1.1,
Door U -factor. U-
U-
❑Complies
❑Does
See the Envelope Assemblies
table for values.
402.3.4
Not
[FR1]1
'❑Not Observable
❑Not Applicable
�.
402.1.1,
Glazing U -factor (area -weighted U-
U-
❑Complies
See the Envelope Assemblies
402.x.1,
average).
❑Does Not
table for values.
402.3.3,
❑Not Observable
402,3.6,
❑Not Applicable
.�
402.5
[FR2]1
303.1,3
U -factors of fenestration products
❑Complies
[FR4]1
are determined in accordance
❑Does Not
with the NFRC test procedure orQ11
;❑Not Observable
taken from the default table.
❑Not Applicable
402.4,1,1
;Air barrier and thermal barrier
❑Complies
Requirement will be met.
[FR23]1
installed per manufacturer's
❑Does Not
A
instructions.
❑Not Observable
❑Not Applicable
402.4.3
Fenestration that is not site built
❑Complies
[FR20]1
:is listed and labeled as meeting
❑Does Not
AAMA /WDMA/CSA 101/i.S.2/A440
❑Not Observable
or has infiltration rates per NFRC
❑Not Applicable
400 that do not exceed code
limits.
402.4.5
IC -rated recessed lighting fixtures
❑Complies
[FR16]2
sealed at housing/interior finish
❑Does Not
and labeled to indicate s2.0 cfm
❑Not Observable
leakage at 75 Pa.
❑Not Applicable
403.2.1
Supply and return ducts in attics
❑Complies
[FR12]1
insulated >= R-8 where duct is
❑Does Not
i>= 3 inches in diameter and >_
[]Not Observable
,
R-6 where < 3 inches. Supply and
❑Not Applicable
return ducts in other portions of
;the building insulated >= R-6 for
!diameter >= 3 inches and R-4,2
for < 3 inches in diameter.
403.3,3.5
: Building cavities are not used as
❑Complies
[FR15]3
ducts or plenums.
❑Does Not
❑Not Observable
❑Not Applicable
403.4
HVAC piping conveying fluids R-
R-
❑Complies
[FR17]2
above 105 9F or chilled fluids
❑Does Not
below 55 °F are insulated to ?R-
'[Not Observable
3'
❑Not Applicable
403.4.1
Protection of insulation on HVAC
❑Complies
[FR24]1
piping.
❑Does Not
❑Not Observable
❑Not Applicable
403.5.3
Hot water pipes are insulated to R-
R-
❑Complies
[FR18]2
>_R-3.
❑Does Not
❑Not Observable
i❑Not Applicable
403.6
Automatic or gravity dampers are
❑Complies
[FR19]2
installed on all outdoor air
❑Does Not
intakes and exhausts.
❑Not Observable
:❑Not Applicable
1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 5 of10
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 6 of 10
Section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.iD
303.1
All installed insulation is labeled
❑Complies
[IN13]2
or the installed R -values
❑Does Not
provided.
i❑Not Observable
E]Not Applicable
402.1.1,
' Wall insulation R -value. If this is a
R-
R-
ClComplies See the Envelope Assemblies
402.2.5,
mass wall with at least Y2 of the
F-1 Wood
❑ Wood
ElDoes Not table for values.
402.2.6
wall insulation on the wall
n Mass
❑ Mass
T- Not Observable
[IN3]1
exterior, the exterior insulation
❑Steel
j E] Steel
C]Not Applicable
requirement applies (FR10).
303.2
Wall insulation is installed per
OComplies
[IN4]1
manufacturer's instructions.
ODoes Not
EINot Observable
❑Nat Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 7 of10
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
402.1.1,
Ceiling insulation R-value.
R-
R- ❑Complies See the Envelope Assemblies
402.2.1,❑Wood
❑Wood ❑Does Not table for values.
402.2.2,
❑ Steel
❑ Steel❑Not Observable
402. ' 6
[Fill
FI1]
❑Not Applicable
303.1.1.1,
;Ceiling insulation installed per
❑Complies
303.2manufacturer's
instructions.
❑Does Not
(F12]1
; Blown insulation marked every
❑Not Observable
300 ftp.
❑Not Applicable
402.23
Vented attics with air permeable
'❑Complies
[F122]2
insulation include baffle adjacent
❑Does Not
;to soffit and eave vents that
❑Not Observable
extends over insulation.
❑Not Applicable
402.2.4
Attic access hatch and door
R-
R- ❑Complies
(FI3]1
insulation >_R-value of the
❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2
I Blower door test @ 50 Pa. <=5
ACH 50 =
ACH 50 = ;❑Complies
[FI17]1
'ach in Climate Zones 1-2, and
❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
i❑Not Applicable
403.2.3
Duct tightness test result of <=4
cfm/100
cfm/100 E❑Complies
[FI4]1
cfm/100 ft2 across the system or
1 ft2
ft2 ❑Does Not
<=3 cfm/100 ft2 without air
❑Not Observable
; handler @ 25 Pa. For rough-in
❑Not Applicable
!tests, verification may need to
occur during Framing Inspection.
403.3.2
Ducts are pressure tested to
cfm/100
cfm/100 ❑Complies
[FI27]1
determine air leakage with
ft2
ft2 ❑Does Not
either: Rough-in test: Total
❑Not Observable
leakage measured with a
❑Not Applicable
pressure differential of 0.1 inch
w.g, across the system including
,the manufacturer's air handler
enclosure if installed at time of
;;test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
:w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1
:Air handler leakage designated
❑Complies
[FI24]1
'by manufacturer at <=2% of
❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1
Programmable thermostats
❑Complies
[F19]2
installed for control of primary
❑Does Not
heating and cooling systems and
❑Not Observable
initially set by manufacturer to
❑Not Applicable
code specifications.
403.1.2
:Heat pump thermostat installed
❑Complies
[FI10]2
on heat pumps.
❑Does Not
❑Not Observable
❑Not Applicable
403.5.1
Circulating service hot water
❑Complies
[FI11]2
`systems have automatic or
❑Does Not
accessible manual controls.
[-]Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 8 of 10
Section
#
Final Inspection Provisions
[Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
403.6.1
All mechanical ventilation system
❑Complies
[F125]2
fans not part of tested and listed
`❑Does Not
HVAC equipment meet efficacy
s❑Not Observable
and air flow limits.
❑Not Applicable
403.2
Hot water boilers supplying heat
❑Complies
[F126]2
through one- or two -pipe heating
❑Does Not
systems have outdoor setback
[_-]Not Observable
control to lower boiler water
❑Not Applicable
temperature based on outdoor
temperature.
403.5.1.1
Heated water circulation systems
❑Complies
❑Does
[F128]2
have a circulation pump. The
Not
system return pipe is a dedicated
❑Not Observable
return pipe or a cold water supply
❑Not Applicable
pipe. Gravity and thermos -
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
Is at set -point temperature and
no demand for hot water exists,
403.5.1.2
'Electric heat trace systems
❑Complies
❑Does Not
[F129]2
'comply with IEEE 515.1 or UL
515. Controls automatically
❑Not Observable
adjust the energy input to the
;C7Not Applicable
heat tracing to maintain the
desired water temperature in the
piping.
403.5.2
Water distribution systems that
❑Complies
❑Does
[F130]2
have recirculation pumps that
Not
pump water from a heated water
❑Nat Observable
supply pipe back to the heated
❑Not Applicable
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4
Drain water heat recovery units
[]Complies
❑Does
(F13112
tested in accordance with CSA
Not
855.1. Potable water -side
❑Not Observable
pressure loss of drain water heat
❑Not Applicable
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404,1
75% of lamps in permanent
❑Complies
❑Does Not
[FI611
fixtures or 75% of permanent
,fixtures have high efficacy lamps.
;❑Not Observable
Does not apply to low -voltage
❑Not Applicable
=lighting.
404.1.1
Fuel gas lighting systems have
❑Complies
❑Does Not
(FI23]3
no continuous pilot light.
❑Not Observable
❑Not Applicable
1 High Impact (Tier 1) 2' Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 9 of 10
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: spec 1 Report date: 06/08/21
Data filename: Untitled.rxl Page 10 of10