ResCheckC�J(REScheck Software Version 4. 5.0
Compliance Certificate
Project 2833 KREJCI BLVD (#OV -20119)
Energy Code:
2009 1ECC
Location:
Blair, Nebraska
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Bldg. faces 0 deg. from North
Conditioned Floor Area:
1,265 ft2
Glazing Area
12%
Climate Zone:
5 (6506 HDD)
Permit Date:
29
Permit Number:
Construction Site:
Owner/Agent: Designer/Contractor:
LOT 47 TRANSFORMATION
HILL ORCHARD VALLEY, INC. ORCHARD VALLEY, INC.
Compliance: 0.0% Better Than Code Maximum UA: 238 Your UA: 238
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Envelope Assemblies
Ceiling 1: Flat Ceiling or Scissor Truss
1,265
12.0
26.0
0.025
32
Comment: CEILINGS (FLAT)
Wall 1: Wood Frame, 16" D.C.
531
13.0
3.3
0,063
29
Orientation: Front
Comment: FRONT WALL
Gerkin 5460 (RO) Glider: Vinyl Frame, Double Pane with Low -E
23
0.290
7
Orientation: Front
Comment: Gerkin
3'0" x 8'0" Thermatru w/ storm door: Glass
24
0.110
3
Orientation: Front
Comment: Thermatru w/ storm door
Door: 2'8" x 6'8" Garage Solidcore: Solid
18
0.390
7
Orientation: Front
Comment: Solidcore
Wall 2: Wood Frame, 16" D.C.
152
13.0
3.3
0.063
10
Orientation: Right side
Comment: RIGHT WALL
Wall 3: Wood Frame, 16" D.C.
331
13.0
3.3
0.063
17
Orientation: Back
Comment: REAR WALL
Gerkin 6' Slider: Glass
41
0.290
12
Orientation: Unspecified
Gerkin 5454 (RO) Glider: Vinyl Frame, Double Pane with Low -E
20
0.290
6
Orientation: Back
Comment: Gerkin
Project Title: 2833 KREJCI BLVD (#OV -20119) Report date: 01/22/21
Data filename: S:\Design\CUSTOMS�OB_OV20119\RES_OV20119_TP047.rck Pagel of 2
Wall 4: Wood Frame, 16" o.c. 352 13.0 3.3 0.063 20
Orientation: Left side
Comment: LEFT WALL
Model 4700 3880 (RO) Stat: Vinyl Frame:Double Pane with Low-E 21 0.290 6
Orientation: Unspecified
Model 4700 3880 (RO) Stat copy 1: Vinyl Frame:Double Pane with Low-E 21 0.290 6
Orientation: Unspecified
Basement Wall 1: Masonry Block with Empty Cells 243 0.0 11.0 0.120 29
Orientation: Front
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 1.5'
Comment: FRONT BSMT WALL
Basement Wall 2: Masonry Block with Empty Cells 171 0.0 11.0 0.054 9
Orientation: Right side
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Comment: RIGHT BSMT WALL
Basement Wall 3: Masonry Block with Empty Cells 372 0.0 11.0 0.054 19
Orientation: Back
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Comment: REAR BSMT WALL
Gerkin 4848 (RO) Glider: Vinyl Frame:Double Pane with Low-E 16 0.290 5
Orientation: Unspecified
Basement Wall 4: Masonry Block with Empty Cells 396 0.0 11.0 0.054 21
Orientation: Left side
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Comment: LEFT BSMT WALL
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version 4.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
VVtS� (Iddm)h--DY000 it)ya Otm, Err)IN4
Name -Title Signature Date
Project Title: 2833 KRE)CI BLVD (#OV -20119) Report date: 01/22/21
Data filename: S:\Design\CUSTOMSVOB_OV20119\RES_0\�20119 TP047.rck Page 2 of 2
r 2009 IECC Energy
41 Efficiency
Certificate
Wall 16.30
Floor 11.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Window 0.29 0.32
Door 0.29
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments