ResCheckQ
Generated by REScheck-Web Software
Compliance Certificate
Project Lehl
Energy Code:
2009 IECC
Location:
Blair, Nebraska
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Bldg. faces 180 deg. from North
Conditioned Floor Area:
1,628 ft2
Glazing Area
10%
Climate Zone:
5 (6506 HDD)
Permit Date:
Permit Number:
0.190 4
Construction Site:
Owner/Agent:
2454 Grant Circle
Blair, NE 68008
Window: Wood Frame
Designer/Contractor:
Jay Nielsen
J Nielsen Construction LLC
1730 State St
Blair, NE 68008
nielsenhomesblair@gmail.com
Compliance: 20.5% Better Than Code Maximum UA: 302 Your UA: 240
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
E(1 i ht1e
Ceiling: Flat Ceiling or Scissor Truss
1,628
0.0
50.0
0.019 31
Wall: Wood Frame, 16" ox.
360
23.0
0.0
0.055 18
Orientation: Front
Door: Solid Door (under 50% glazing)
19
0.190 4
Orientation: Front
Window: Wood Frame
22
0.280 6
Orientation: Front
Wall l: Wood Frame, 16" o.c.
477
23.0
0.0
0.055 25
Orientation: Right side
Door 1: Solid Door (under 50% glazing)
19
0.190 4
Orientation: Right side
Wall 2: Wood Frame, 16" o.c.
360
23.0
0.0
0.055 15
Orientation: Back
Window 3: Wood Frame
22
0.280 6
Orientation: Back
Window 2: Wood Frame
15
0.250 4
Orientation: Back
Window 1: Wood Frame
15
0.250 4
Orientation: Back
Window 1: Wood Frame
22
0.280 6
Orientation: Back
Project Title: Lehi
Report date: 10/21/20
Data filename:
Pagel of 8
Window: Other
15
0.250 4
.Orientation: Back
Wall 3: Wood Frame, 16" o.c.
477
23.0 0.0 0.055 25
Orientation: Left side
Door 2: Glass Door (over 50% glazing)
30
0.290 9
Orientation: Left side
Basement: Solid Concrete or Masonry
360
0.0 15.0 0.044 16
Orientation: Front
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Basement: Solid Concrete or Masonry
477
0.0 15.0 0.044 21
Orientation: Right side
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Basement: Solid Concrete or Masonry
360
0.0 15.0 0.044 16
Orientation: Back
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Basement: Solid Concrete or Masonry
477
0.0 15.0 0.044 20
Orientation: Left side
Wall height: 9.0'
Depth below grade: 8.0'
Insulation depth: 9.0'
Window: Wood Frame
22
0.280 6
Orientation: Left side
Compliance Statement. The proposed building design described here is consistent
with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed t
me the 2009 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory re
ents listed ' e
check Inspection Checklist.
Name - Title ignat e
Date
Project Title: Lehi Report date: 10/21/20
Data filename: Page 2 of 8
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Seeti®n
#
Pre-Inspection/Plan Review
Plans Verified
Value
field Verified
Value Complies?
Comments/Assumptions
& Req.l®
103.2
;Construction drawings and ;
I❑Complies
[PR1]1
documentation demonstrate
UDoes Not
'
energy code compliance for the
❑Not Observable
building envelope,i
I
❑Not Applicable
103.2,
;Construction drawings and
❑Complies
403.7
;documentation demonstrate
I❑Does Not j
[PR3]1
energy code compliance for
❑Not Observable
lighting and mechanical systems. i
❑Not Applicable
Systems serving multiple ;
I dwelling units must demonstrate
compliance with the commercial
;code.
403.6
Heating and cooling equipment is:
Heating:
Heating: ;❑Complies
[PR2]2
sized per ACCA Manual S based
Btu/hr
Btu/hr :❑Does Not
on loads per ACCA Manual J or
Cooling:
Cooling: I❑Not Observable
-
other approved methods.
Btu/hr
j Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lehi Report date: 10/21/20
Data filename: Page 3 of 8
Section
Foundation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.lb
402.1.1
Conditioned basement wall ', R-
R- ;❑Complies ;See the Envelope Assemblies
[F04]1
insulation R -value. Where interior:
:❑Does Not table for values.
s
insulation is used, verification
j❑Not Observable
may need to occur during
;❑Not Applicable
;Insulation Inspection. Not
(required in warm -humid locations
in Climate Zone 3.
303.2
;Conditioned basement wall i
❑Complies
[F05]1
insulation installed per E
T❑Does Not
manufacturer's instructions.
i❑Not Observable
i
'❑Not Applicable
402.2.7
;Conditioned basement wall ft
ft ;❑Complies ;See the Envelope Assemblies
[F06]1
insulation depth of burial or
❑Does Not table for values.
distance from top of wall.
❑Not Observable
j❑Not Applicable
303.2.1
A protective covering is installed
I ❑Complies
[FO11]2
Ito protect exposed exterior
U❑Does Not
'_&
insulation and extends a
minimum of 6 in. below grade.
-]Not Observable
❑Not Applicable
403.8
;Snow- and ice -melting system
T❑Complies
[FO12]2
;controls installed.
I❑Does Not
1Q111
❑Not Observable
r❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Lehl Report date: 10/21/20
Data filename: Page 4 of 8
�edtion
Framing) / Rough-in Inspection
Plans Verified
Value
Field Verified
Value
:Complies?
Comments/Assumptions
& Req.ID
402.1.1,
Door U-factor. ;
U-
U- ;❑Complies ;See the Envelope Assemblies
402.3.4
❑Does Not ;table for values.
[FRl]1 e
❑Not Observable , ;
NO ;
[]Not Applicable
402.1.1, ;
Glazing U-factor (area-weighted ',
U-
U- ;❑Complies ;See the Envelope Assemblies
402.3.1, .average).❑Does
Not itable for values.
402.3.3, I
❑Not Observable
402.5
[FR2]1
;
; :❑Not Applicable
J
;
303.1.3
U-factors of fenestration products j
❑Complies
[FR4]1
are determined in accordance
❑Does Not
!with
the NFRC test procedure or
p
taken from the default table.
1❑Not Observable
❑Not Applicable
402.4.4 ;
Fenestration that is not site built❑Complies
[FR20]1
is listed and labeled as meeting
iElDoes Not
1AAMA/WDMA/CSA
, i
101/I.S.2/A440
or has infiltration rates per NFRC ,
l❑Not Observable
1400
that do not exceed code ;
�❑Not Applicable
limits.
402.4.5 }IC-rated
recessed lighting fixtures!
❑Complies
[FR16]2 ;sealed
at housing/interior finish
❑Does Not
and labeled to indicate <_2.0 cfm
❑Not Observable
1
leakage at 75 Pa.
T❑Not Applicable
403.2.1 ;Supply
ducts in attics are ;
R
R- ;❑Complies
[FR12]1
'insulated to >_11-8. All other ducts
R-
R-T❑Does Not
i
unconditioned s
in unconaces or
p
:❑Not Observable
outside the building envelope are ;
❑Not Applicable
insulated to >_11-6.
403.2.2
;All joints and seams of air ducts, i
❑Complies
[FR13]1
1 air handlers, filter boxes, and
j❑Does Not
building cavities used as return
ducts are sealed.
❑Not Observable
❑Not Applicable
403.2.3
j Building cavities are not used for
❑Complies
[FR15]3
supply ducts.
❑Does Not
❑Not Observable j
❑Not Applicable
403.3
HVAC piping conveying fluids I
R-
R- ;❑Complies I
[FR17]2
I above 105 °F or chilled fluids I
Z❑Does Not
below 55 °F are insulated to >_R-
;❑Not Observable
3
❑Not Applicable
403.4
;Circulating service hot water
R-
R-❑Complies
[FR18]2
I pipes are insulated to R-2.
;❑Does Not
�,
❑Not Observable
❑Not Applicable
403.5
;Automatic or gravity dampers are;
❑Complies
[FR19]2
installed on all outdoor air
❑Does Not
!intakes and exhausts.
;❑Not Observable j
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Lehl Report date: 10/21/20
Data filename: Page 5 of 8
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 13 ,;1 Low Impact (Tier 3)
Project Title: Lehl Report date: 10/21/20
Data filename: Page 6 of 8
Section
##
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& RegJD
�;see
402.1.1, ;Ceiling
insulation R -value. Where ; R-
R-
;❑Complies the Envelope Assemblies
402.2.1, !>
R-30 is required, R-30 can be ❑ Wood
; ❑ Wood
�❑Does Not table for values.
402.2.2used
[Fill,
if insulation is not ❑ Steel
;compressed at eaves. R-30 may
❑ Steel
;
;❑Not Observable
;g -„j
; be used for 500 ft2 or 20%
;❑Not Applicable
(whichever is less) where
sufficient space is not available.
303.1.1.1,
;,Ceiling insulation installed per ;
❑Complies
303.2
manufacturer's instructions. I
❑Does Not
[F12]1
Blown insulation marked every
'
Observable
-
300 ft;!.1❑Not
i
❑Not Applicable
402.2.3
;Attic access hatch and door; R-
R -❑Complies
[FI3]1
insulation >_R -value of the
❑Does Not
!adjacent assembly.
; ,❑Not Observable
❑Not Applicable
402.4.2,
; Building envelope tightness ACH 50 =
ACH 50 =
;❑Complies
402.4.2.1
!verified by blower door test result
:❑Does Not
[FI17]1
of <7 ACH at 50 Pa. This
;❑Not Observable
1
requirement may instead be met
❑Not Applicable
;via visual inspection, in which
case verification may need to
;occur during Insulation
j
Inspection.
403.2.2
1 Post construction duct tightness cfm
cfm
;❑Complies ;
[FI4]1
; test result of 158 cfm to outdoors, !
❑Does Not
dor s12 cfm across systems. Or,
;❑Not Observable
rough -in test result of :56 cfm
!❑Not Applicable
pp
!across systems or <_4 cfm ;
:without air handler. Rough -in test:
;
;verification may need to occur
;during Framing Inspection,
403.1.1
Programmable thermostats
❑Complies
[Flg]z
ainstalled on forced air furnaces.
'❑Does Not
1
❑Not Observable ;
s❑Not Applicable
403.1.2
1 Heat pump thermostat installed
❑Complies
[FI10]2
on heat pumps.
1'F -]Does Not
t
[:]Not Observable ,
❑Not Applicable
403.4
Circulating service hot water
,❑Complies
[FI11]2
systems have automatic or
j❑Does Not
accessible manual controls.
❑Not Observable
r
❑Not Applicable
404.1
;50% of lamps in permanent
;❑Complies
[F16]1
Mixtures are high efficacy lamps.
'❑Does Not
;9
❑Not Observable
' f
❑Not Applicable
401.3
Compliance certificate posted.
❑Complies ;
[FI712
❑Does Not j
{❑Not Observable
❑Not Applicable
303.3
l Manufacturer manuals for
i ❑Complies
[FI18]3
mechanical and water heating
❑Does Not
equipment have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Lehi Report date: 10/21/20
Data filename: Page 7 of 8
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Lehl Report date: 10/21/20
Data filename: Page 8 of 8