ResCheckEnergy Code: 2009 IECC Location: Omaha, Nebraska Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,620 ft2 Glazing Area 19% Climate Zone: 5 (6300 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Omaha, NE New Construction Architectural Plans Compliance: 1.9% Better Than Code Maximum UA: 318 Your UA: 312 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. AIm Ceiling area of home forming top of insulation envelope: Flat Ceiling or Scissor 1,620 38.0 0.0 O.u3u 49 Truss Wall area of home forming sides of insulation envelope: Solid Concrete or 1,523 19.0 0.0 0.059 71 Masonry: Interior Insulation Window area of home using energy efficient units: Vinyl/Fiberglass 244 0.290 71 Frame:Double Pane with Low -E Energy efficient door unit: Solid 21 0.200 4 Energy efficient door unit: Glass 42 0.300 13 20 minute fire door: Solid 21 0.200 4 Basement wall area of home forming bottom of insulation envelope: Solid 1,474 0.0 6.0 0.068 100 Concrete or Masonry Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Compliance Statement, The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.7.0 and to comply with the mandatory requirements listed in the RESche�k Inspection Checklist. lobe Leonard 5/5/2020 Name - Title Signature 0 Date Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 1 of 7 REScheck Software i C�J( Inspection Checklist Energy Code: 2009 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans verified Field verified f& Pre-inspection/Flan I?eview ] `/slue I value Complies? Comments/Assumptions & Req.I13 _ __ ❑Complies 103.2 Construction drawings and ❑Does Not [PR111 documentation demonstrate energy code compliance for the ❑Not Observable building envelope. ❑Not Applicable 103.2, Construction drawings and ;❑Complies ❑Does Not 403.7 documentation demonstrate [PR311 energy code compliance for ❑Not Observable lighting and mechanical systems. ❑Not Applicable systems serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is ! _ Heating: Heating; ❑Complies [PR2J2 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads per ACCA Manual J or Cooling: Cooling: ❑Not Observable - other approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 2 of 7 �� Foundation, Inspection � Plans Verified value Meld verifled value Complies? C,,,ments/Assumptions Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies see the Envelope Assemblies table for values. [F04]1 insulation R-value. Where interior ❑Does Not j insulation is used, verification ;❑Not Observable may need to occur during ❑Not Applicable Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]' insulation installed per ❑Does Not s manufacturer's instructions. ,❑Not Observable ❑Not Applicable 402.2.7 Conditioned basement wall ft ft ❑Complies ;see the Envelope Assemblies ❑Does table for values. [F0613 insulation depth of burial or Not distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 ;A protective covering is installed ❑Complies [FO 11]2 `to protect exposed exterior `❑Does Not insulation and extends a ,❑Not Observable , - :minimum of 6 in. below grade. ❑Not Applicable 403.8 Snow- and ice-melting system ❑Complies [FO12]2 controls installed, i❑Does Not ❑Not Observable '❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2, Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 3 of 7 Section # Fraa-ming / Rough -in Inspection I Flans Verified Field 'Verified Complies? C®ararraents/Assuanptia3rls Value Value Req'ID 402.1.1, Door U -factor. U- U- ❑Complies See the Envelope Assemblies table for values. 402.3.4 ❑Does Not (FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U factor (area weighted U U ❑Complies See the Envelope Assemblies Not table for values. 402.3.1, average).❑Does 402.3.3, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U -factors of fenestration products :❑Complies (FR4]1 are determined in accordance ;❑Does Not with the NFRC test procedure or !❑Not Observable - taken from the default table. ❑Not Applicable 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting '❑Does Not ;AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable '. or has infiltration rates per NFRC❑Not Applicable 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures :❑Complies ❑Does Not [FR16]2 sealed at housing/interior finish and labeled to indicate _<2.0 cfm ❑Not Observable leakage at 75 Pa.❑Not Applicable 403.2.1 Supply ducts in attics are R- R -❑Complies ❑Does Not [FR12]1 insulated to >_R-8. All other ducts R- R- in unconditioned spaces or ❑Not Observable outside the building envelope are ❑Not Applicable insulated to >_R-6. 403.2.2 All joints and seams of air ducts, ❑Complies ❑Does Not [FR13]1 air handlers, filter boxes, and building cavities used as return !❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3: ' Building cavities are not used for '❑Complies [FR15]3 ;supply ducts. ❑Does Not ,❑Not Observable ' ❑Not Applicable. 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 9F or chilled fluids ❑Does Not below 55 9F are insulated to >_R ❑Not Observable 3. ❑Not Applicable 403.4 Circulating service hot water R- R- ❑Complies ❑Does Not (FR18]2 pipes are insulated to R-2. ,❑Not Observable ; ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies ❑Does Not [FR19]2 installed on all outdoor air intakes and exhausts. ;❑Not Observable []Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2'+ Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 4 of 7 Secti®nerified Insulation inspection plans rifi�:d Field v I Complies? C®rnrments/Assurerptirsns vavelue value Re 113 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R -values E]Does Not provided. pNot Observable E]Not Applicable 402.1.1, Wall insulation R -value. If this is a:, R- R- '.ElComplies See the Envelope Assemblies 402.2.4, mass wall with at least 1A of the Wood ❑ Wood Oboes Not table for values. 402.2.5 wall insulation on the wall EJ Mass ❑ Mass ;Not Observable [IN3]1 exterior, the exterior insulation E]Steel E]Steel E]Not Applicable requirement applies. 303.2 Wall insulation is installed per ` ElComplies [IN4]1 manufacturer's instructions. ElDoes Not EINot Observable ONot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 2Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 5 of 7 Sectiern �# I Final Inspection Provisions � Y4 Maras Verified Field Verified I Compiles. Cornrnents/Assumptions Value Value & Req.ID 402.1.1, Ceiling insulation R -value. Where R- R- ❑Complies see the Envelope Assemblies table for values. ❑Does 402.2.1, > R-30 is required, R-30 can be E] Wood ❑ Wood Not 402.2.2 used if insulation is not E] Steel ❑ Steel ❑Not Observable [Fill' compressed at eaves, R-30 may ❑Not Applicable be used for 500 ftz or 20% (whichever is less) where sufficient space is not available. 303.1.1.1, Ceiling insulation installed per lElComplies 303.2 manufacturer's instructions. '❑Does Not [FI2]' Blown insulation marked every ;❑Not Observable 300 ftz. ❑Not Applicable 402.2.3 Attic access hatch and door R- R- ❑Complies [FI3]' insulation ?R -value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI17]' of <7 ACH at 50 Pa. This ❑Not Observable requirement may instead be met ❑Not Applicable via visual inspection, in which case verification may need to occur during Insulation Inspection. 403.2.2 Post construction duct tightness % cfm cfm ❑Complies [FI4]' test result of :58 cfm to outdoors, ❑Does Not or :512 cfm across systems. Or, ❑Not Observable rough -in test result of :56 cfm ❑Not Applicable across systems or <_4 cfm without air handler. Rough -in test verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats ❑Complies [Flg]2 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI 10]2 on heat pumps. ❑Does Not ❑Not Observable '❑Not Applicable 403.4 Circulating service hot water ❑Complies [FIJI]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable �'❑Complies ❑Not Applicable 404.1 50% of lamps in permanent [FI6]' fixtures are high efficacy lamps. ❑Does Not ❑Not Observable j❑Not Applicable 401.3 Compliance certificate posted.❑Complies [F17]2 ❑Does Not 1❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 , mechanical and water heating ❑Does Not ;equipment have been provided. ❑Not Observable . ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 6 of 7 1 High Impact (Tier 1) 2 i' Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 05/05/20 Data filename: C:\Users\New\Google Drive\Rescheckinfo Google Drive\OmahaNE.rck Page 7 of 7