ResCheck.tifREScheck Software Version 4.6.4 Compliance Certificate Project Mark Bolander Residence Energy Code: 2009 IECC Location: Blair, Nebraska Construction Type: Single-family Project Type: New Construction Orientation: Unspecified Conditioned Floor Area: 5,053 ft2 Glazing Area 11% Climate Zone: 5 (6506 HDD) Permit Date: 9 Permit Number: Construction Site: Owner/Agent: Valley Ridge Estates, Lot 4 Blair, NE 4860 Fixed: Wood Frame:Double Pane with Low -E Designer/Contractor: Randy Popken Christensen Lumber 714 South Main Fremont, NE 68025 (402)727-2211 randypopken@christensenlumber.c om o o e e Compliance: 2.1% Better Than Code Maximum UA: 660 Your UA: 646 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Rear Walkout Wall: Wood Frame, 16" D.C. 378 21.0 0.0 0.057 16 Orientation: Back 3050-2W DH: Wood Frame:Double Pane with Low -E 30 0.310 9 Orientation: Unspecified 4860 Fixed: Wood Frame:Double Pane with Low -E 20 0.310 6 Orientation: Unspecified 4860 Fixed: Wood Frame:Double Pane with Low -E 20 0.310 6 Orientation: Unspecified 4860 Fixed: Wood Frame:Double Pane with Low -E 20 0.310 6 Orientation: Unspecified Left Side Walkout Wall: Wood Frame, 16" o.c. 99 21.0 0.0 0.057 6 Orientation: Left side Right Side Walkout Wall: Wood Frame, 16" D.C. 282 21.0 0.0 0.057 13 Orientation: Right side 3050r2W DH: Wood Frame:Double Pane with Low -E 30 0.310 9 Orientation: Unspecified Patio Door: Glass 20 0.290 6 Orientation: Unspecified Rear Foundation Wall: Solid Concrete or Masonry: interior Insulation 144 13.0 0.0 0.083 12 Orientation: Right side Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 1 of 10 Right Foundation Wall: Solid Concrete or Masonry: interior Insulation 351 13.0 0.0 0.083 29 Orientation: Right side Front Foundation Wall: Solid Concrete or Masonry: Interior Insulation 522 13.0 0.0 0.083 43 Orientation: Front Left Foundation Wall: Solid Concrete or Masonry: interior Insulation 534 13.0 0.0 0.083 44 Orientation: Left side Front Floor Rim: Wood Frame, 16" o.c. 59 21.0 0.0 0.057 3 Orientation: Front Right Floor Rim: Wood Frame, 16" o.c. 70 21.0 0.0 0.057 4 Orientation: Right side Rear Floor Rim: Wood Frame, 16" o.c. 59 21.0 0.0 0.057 3 Orientation: Back Left Floor Rim: Wood Frame, 16" o.c. 70 21.0 0.0 0.057 4 Orientation: Left side First Floor Front Wall: Wood Frame, 16" o.c. 568 21.0 0.0 0.057 26 Orientation: Front 2650-2W Fixed (Dining Room): Wood Frame:Double Pane with Low -E 25 0.310 8 Orientation: Unspecified 2650-2W Casement (Office): Wood Frame:Double Pane with Low -E 25 0.320 8 Orientation: Unspecified Entry Door Sidelights: Wood Frame:Double Pane with Low -E 13 0.320 4 Orientation: Unspecified Entry Door Transom: Wood Frame:Double Pane with Low -E 10 0.310 3 Orientation: Unspecified Entry Door: Solid 20 0.140 3 Orientation: Unspecified House/Garage Door: Solid 20 0.140 3 Orientation: Unspecified First Floor Right Side Wall: Wood Frame, 16" o.c. 655 21.0 0.0 0.057 34 Orientation: Right side 3040 DH w/ 24" Transom (Powder Room): Wood Frame:Double Pane with Low- 18 0.310 6 E Orientation: Unspecified 3050 DH (Eating Area): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified Eating Area / Deck Door: Glass 20 0.290 6 Orientation: Unspecified First Floor Rear Wall: Wood Frame, 16" o.c. 531 21.0 0.0 0.057 20 Orientation: Back 4050 Fixed w/ 24" Transom (Great Room): Wood Frame:Double Pane with Low- 28 0.310 9 E Orientation: Unspecified 4050 Fixed w/ 24" Transom (Great Room): Wood Frame:Double Pane with Low- 28 0.310 9 E Orientation: Unspecified 4050 Fixed w/ 24" Transom (Great Room): Wood Frame:Double Pane with Low- 28 0.310 9 E Orientation: Unspecified 3050 Fixed (Eating Area): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified 3050 Fixed (Eating Area): Wood Frame:Double Pane with Law -E 15 0.310 5 Orientation: Unspecified 3050 Fixed (Eating Area): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified 3' Archtop (Eating Area): Wood Frame:Double Pane with Low -E 4 0.310 1 Orientation: Unspecified 3030 DH (Kitchen): Wood Frame:Double Pane with Low -E 9 0.310 3 Orientation: Unspecified Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 2 of 10 2650 Fixed w/ Transom (Master Bedroom): Wood Frame:Double Pane with 18 0.310 6 Low -E Orientation: Unspecified 2650 Fixed w/ Transom (Master Bedroom): Wood Frame:Double Pane with 18 0.310 6 Low -E Orientation: Unspecified First Floor Left Side Wall: Wood Frame, 16" o.c. 528 21.0 0.0 0.057 26 Orientation: Left side 3050 DH (Eating Area): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified 3050 DH (Master Bedroom): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified 3050 DH (Master Bedroom): Wood Frame:Double Pane with Low -E 15 0.310 5 Orientation: Unspecified 4848 Fixed (Bath #1): Wood Frame:Double Pane with Low -E 16 0.310 5 Orientation: Unspecified 2030 DH (Laundry): Wood Frame:Double Pane with Low -E 6 0.310 2 Orientation: Unspecified Second Floor Front Rim: Wood Frame, 16" o.c. 49 21.0 0.0 0.057 3 Orientation: Front Second Floor Right Side Rim: Wood Frame, 16" o.c. 35 21.0 0.0 0.057 2 Orientation: Right side Second Floor Rear Rim: Wood Frame, 16" o.c. 49 21.0 0.0 0.057 3 Orientation: Back Second Floor Left Side Rim: Wood Frame, 16" o.c. 35 21.0 0.0 0.057 2 Orientation: Left side Second Floor Front Wall: Wood Frame, 16" o.c. 391 21.0 0.0 0.057 20 Orientation: Front 2650-2W Casement w/ Transom (Bedroom #2): Wood Frame:Double Pane with 35 0.320 11 Low -E Orientation: Unspecified Second Floor Right Side Wall: Wood Frame, 16" o.c. 280 21.0 0.0 0.057 16 Orientation: Right side Second Floor Rear Wall: Wood Frame, 16" o.c. 391 21.0 0.0 0.057 13 Orientation: Back 4040 Fixed (Great Room Upper): Wood Frame:Double Pane with Low -E 46 0.310 14 Orientation: Unspecified 4040 Fixed (Great Room Upper): Wood Frame:Double Pane with Low -E 46 0.310 14 Orientation: Unspecified 4040 Fixed (Great Room Upper): Wood Frame:Double Pane with Low -E 46 0.310 14 Orientation: Unspecified 2640 Casement (Loft): Wood Frame:Double Pane with Low -E 10 0.320 3 Orientation: Unspecified 2640 Casement (Loft): Wood Frame:Double Pane with Low -E 10 0.320 3 Orientation: Unspecified Second Floor Left Side Wall: Wood Frame, 16" o.c. 280 21.0 0.0 0.057 15 Orientation: Left side 2448-2W Casement (Bedroom #3): Wood Frame:Double Pane with Low -E 22 0.320 7 Orientation: Unspecified Master Bedroom Cantilever: All -Wood Joist/Truss:Over Outside Air 11 21.0 0.0 0.044 0 Office Cantilever: All -Wood Joist/Truss:Over Outside Air 8 21.0 0.0 0.044 0 Dining Room Cantilever: All -Wood J oist/Truss: Over Outside Air 8 21.0 0.0 0.044 0 Powder Room Cantilever: All -Wood Joist/Truss:Over Outside Air 6 21.0 0.0 0.044 0 Kitchen Cantilever: All -Wood Joist/Truss:Over Outside Air 6 21.0 0.0 0.044 0 Bedroom #2 Cantilever: All -Wood J o ist/Truss: Over Outside Air 16 21.0 0.0 0.044 1 Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 3 of10 Bedroom #3 Over Garage: All -Wood joist/Truss:Over Unconditioned Space 71 21.0 0.0 0.044 3 Flat Ceiling: Flat Ceiling or Scissor Truss 1,841 21.0 29.0 0.020 37 Master Bedroom Cathedral Ceiling: Cathedral Ceiling 374 38.0 0.0 0.027 10 Eating Area Cathedral Ceiling: Cathedral Ceiling 156 38.0 0.0 0.027 4 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 4 of 10 REScheck Software Version 4.6.4 Inspection Checklist Energy Code: 2009 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 103.2 ;Construction drawings and ; ❑Complies [PR1]1 :documentation demonstrate j ;❑Does Not ;energy code compliance for the i 3❑Not Observable ;building envelope. i j❑Not Applicable 103.2, ;Construction drawings and I ❑Complies 403.7 'documentation demonstrate :❑Does Not [PR3]1 :energy code compliance for ❑Not Observable ; ;lighting and mechanical systems. ❑Not Applicable 'Systems serving multiple ;dwelling units must demonstrate ' ;compliance with the commercial code. j 403.6 :Heating and cooling equipment is; Heating: Heating: ;❑Complies [PR2]2 !sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads per Manual j or Cooling:Cooling: ❑Not Observable other approved methods. 7 Btu/hr Btu/hr t❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N 191620\Estimat! ng\REScheck.rck Page 5 of 10 303.2.1 A protective covering is installed to ;LJComplies [FO11]2 :protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ;❑Not Observable ;grade. ❑Not Applicable 403.8 ;Snow- and ice -melting system controls,LJComplies [FO12]2 installed. ;❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) ]-2-[-medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 6 of 10 Section # Framing / Rough -In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions &'Req.ID' 402.1.1, Door U -factor. ; U- U- ;❑Complies ;See the Envelope Assemblies 402.3.4 :❑Does Not :table for values. [FR1]1 ; ; I❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U -factor (area -weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, :average). :❑Does Not table for values. 402.3.3, ' ❑Not Observable ; [FR2]1 ;❑Not Applicable 1 I I I I I I I 1 303.1.3 IU -factors of fenestration products; ❑Complies [FR4]1 are determined in accordance 1 1❑Does Not U) ;with the NFRC test procedure or I j❑Not Observable ;taken from the default table. I ❑Not Applicable 402.4.4 ;Fenestration that is not site built iDComplies [FR20]1 is listed and labeled as meeting AAMA/WDMA/CSA 101/I.S.2/A440 r +❑Does Not I I 9 or has infiltration rates per NFRC l❑Not Observable 3❑Not Applicable ,400 that do not exceed code ; limits. 4 I 402.4.5 IC -rated recessed lighting fixtures; ❑Complies ; [FR16]2 Isealed at housing/interior finish j❑Does Not :and labeled to indicate 52.0 cfm I❑Not Observable ; leakage at 75 Pa. ❑Not Applicable 403.2.1 ;Supply ducts in attics are R- R- :"Complies ; [FR12]1 insulated to >_R-8. All other ducts R- R- F❑Does Not lin unconditioned spaces or I ❑Not Observable ,outside the building envelope are linsulated to >_R-6. ;❑Not Applicable ; 403.2.2 ;All joints and seams of air ducts, 1 ❑Complies [FR13]1 lair handlers, filter boxes, and i j❑Does Not ;building cavities used as return I ❑Not Observable ;ducts are sealed. j❑Not Applicable 403.2.3 Building cavities are not used for ❑Complies [FR15]3 ;supply ducts. 10Does Not jf ,� 1❑Not Observable {❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ;❑Complies [FR17]2 !above 105 °F or chilled fluids :❑Does Not (below 55 °F are insulated to >_R- Q) ; ;❑Not Observable 3. l :❑Not Applicable 403.4 ;Circulating service hot water R- R- j❑Complies [FR18]2 'I pipes are insulated to R-2. ❑Does Not ;❑Not Observable ' :[:]Not Applicable 403.5 ;Automatic or gravity dampers are ;❑Complies ; [FR19]2 Hnstalled on all outdoor air ❑Does Not intakes and exhausts. 1❑Not Observable ; I l ❑Not Applicable ; Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 7 of 10 Section # Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions &Req.113 303.1 ;All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not ` provided. ;❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, Wood ; ❑ Wood :❑Does Not table for values. 402.2.6 [INl]l ❑ Steel ❑ Steel :❑Not Observable QV ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.6 manufacturer's instructions, and € ❑Does Not [IN2)1 :in substantial contact with the ;❑Not Observable underside of the subfloor. ❑Not Applicable ; 402.1.1, Wall insulation R-value. If this is a: R- R- ;❑Complies ;See the Envelope Assemblies 402.2.4, mass wall with at least 1/� of the:Wood j ❑ Wood ;❑Does Not table for values. 402.2.5 [IN3]1 ;wall insulation on the wall ;exterior, the exterior insulation � E] Mass ❑ mass❑Not Observable :requirement applies. I 1 1 I I E] Steel i i I I 1 I ❑Steel ;❑Not Applicable 1 I , 1 I I 1 303.2;Wall insulation is installed per ❑Complies [IN4] manufacturer's instructions, i I❑Does Not � t ❑Not Observable , ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 8 of 10 Section # Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 402.1.1, ,Ceiling insulation R -value. Where R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, > R-30 is required, R-30 can be Wood ❑Wood ;❑Does Not ;table for values. 402.2.2 [FI1]1 ;used if insulation is not ❑ Steel ;compressed at eaves. R-30 may ❑ Steel ;❑Not Observable be used for 500 ftz or 20% :❑Not Applicable ;(whichever is less) where ; :sufficient space is not available. ; 303.1.1.1, ;Ceiling insulation installed per 3❑Complies 303.2 : manufacturer's instructions, r❑Does Not [FI211 ;Blown insulation marked every : ; 3❑Not Observable - ;300 ftz. ; ❑Not Applicable 402.2.3 ;Attic access hatch and door R- R- I❑Complies [FI3]1 :insulation zR-value of the :❑Does Not :adjacent assembly. ;❑Not Observable j❑Not Applicable 402.4.2, ;Building envelope tightness ACH 50 = ACH 50 = ;❑Complies 402.4.2.1 :verified by blower door test result ;❑Does Not [FI17]1 :of <7 ACH at 50 Pa. This ❑Not Observable ; ;requirement may instead be met :via visual inspection, in which ;❑Not Applicable :case verification may need to ;occur during Insulation Inspection. 403.2.2 ; Post construction duct tightness cfm cfm ;❑Complies [FI4]1 test result of :58 cfm to outdoors, ❑Does Not �) or -512 cfm across systems. Or, Observable ; ;rough -in test result of :56 cfm _< :across systems or 4 cfm : ,❑Not ;❑Not Applicable ; :without air handler. Rough -in test: ;verification may need to occur :during Framing Inspection. 403.1.1 Programmable thermostats inComplies [Fl 9]2 ( installed on forced air furnaces. :❑Does Not aQ11 ❑Not Observable , y j❑Not Applicable 403.1.2 Heat pump thermostat installed ; ;❑Complies [F1 10]2 on heat pumps. I ❑Does Not ;& ;❑Not ; Observable j❑Not Applicable 403.4 ;Circulating service hot water i' ❑Complies [Fl 11]2 :systems have automatic or { ❑Does Not accessible manual controls. ;❑Not Observable ; j j❑Not Applicable 404.1 50% of lamps in permanent ❑Complies [FI6]1 ;fixtures are high efficacy lamps. , ❑Does Not j❑Not Observable j❑Not Applicable 401.3 ;Compliance certificate posted. ; j❑Complies [F17 ]2 j } j❑Does Not f ;❑Not Observable I UNot Applicable 303.3 ;Manufacturer manuals for { 7❑Complies [FI18]3 :mechanical and water heating i ?❑Does Not :equipment have been provided, 1 ❑Not Observable j❑Not Applicable Additional Comments/Assumptions: 1 JHIgh Impact (Tier 1) 2 Medium Impact (Tier 2) 13'1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 9 of 10 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Mark Bolander Residence Report date: 11/04/19 Data filename: P:\Projects\2019\N191620\Estimating\REScheck.rck Page 10 of10